Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 8434 Multi-Conductor - Special Audio, Communication and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 25 AWG stranded (7x33) tinned copper/tinned copper covered steel conductors, polyethylene insulation, overall Beldfoil shield (100% coverage), 25 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 2 25 7x33 3 strands tinned copper + 4 strands tinned copper covered steel Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PE - Polyethylene 0.015 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape w/Shorting Fold (foil side out) 100.000 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape (foil side in) 100.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 25 7 x 33 awg 3 strands tinned copper + 4 strands tinned copper covered steel Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .020 Overall Cable Overall Nominal Diameter: 0.165 in. Pair Pair Color Code Chart: Number Color 1 Shielded: Red & Black 2 Unshielded: Green & White Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C Non-UL Temperature Rating: 80C Bulk Cable Weight: 12 lbs/1000 ft. Max. Recommended Pulling Tension: 41 lbs. Min. Bend Radius/Minor Axis: 1.750 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 2 08-26-2016Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 8434 Multi-Conductor - Special Audio, Communication and Instrumentation Cable EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) .2 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 25 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 40 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 45.5 Ind. Pair Nominal Shield DC Resistance 20 Deg. C: 18.900 Ohm/1000 ft Max. Operating Voltage - Non-UL: Voltage 400 V RMS Max. Recommended Current: Current 1.3 Amps per conductor 25C Notes (Overall) Notes: Red and Black pair 100% Beldfoil shielded (foil side out in contact with drain wire). 3 copper, 4 copper-covered steel strands in each conductor. Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 8434 060U1000 1,000 FT 14.000 LB CHROME 4 25 PE SH PVC 8434 060100 100 FT 2.000 LB CHROME 4 25 PE SH PVC 8434 0601000 1,000 FT 14.000 LB CHROME C 4 25 PE SH PVC 8434 060500 500 FT 7.000 LB CHROME 4 25 PE SH PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 11-13-2012 2016 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 08-26-2016