Product: 85241 Electronic, 3 C 16 Str TC, ETFE Ins, OS, ETFE Jkt Product Description High Temperature Electronic, 3 Conductor 16AWG (19x29) Tinned Copper, ETFE Insulation, Overall Beldfoil Shield, ETFE Outer Jacket Technical Specifications Product Overview Suitable Applications: extreme high/low temperature environments chemical resistant low voltage analog signals (4-20ma, 0-10v, ...) low voltage control (24v, ) instrumentation Construction Details Conductor Element Number of Element AWG Stranding Material Conductor(s) 3 16 19x29 TC - Tinned Copper Insulation Element Material Thickness in. Color Code Conductor(s) ETFE - Ethylene Tetrafluoroethylene 0.014 Black, Red, Green Outer Shield Material Shield Type Material Coverage Drainwire Type Tape Alum / Kapton 100% 18 AWG (7x26) TC Outer Jacket Material Material Thickness Nom. Diameter ETFE - Ethylene Tetrafluoroethylene 0.020 in 0.225 in Cable Diameter (Nominal): 0.225 in Electrical Characteristics Electricals Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Max. Current Conductor(s) 4.27 Ohm/1000ft 34 pF/ft 61.2 pF/ft 7 Amps per Conductor at 25C Voltage Non-UL Voltage Rating 350 V Mechanical Characteristics Temperature Operating -60C to +150C Bend Radius Stationary Min. Installation Min. 2.25 in 2.3 in Max. Pull Tension: 142 lbsBulk Cable Weight: 45 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor Sustainability: CA Prop 65 Flammability / Fire Resistance: UL1685 (UL Loading), IEC 60332-1-2 CPR Euroclass: Eca European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Product Notes Notes: Tefzel and Kapton are DuPont trademarks. History Update and Revision: Revision Number: 0.332 Revision Date: 07-31-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.