Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 88109 Multi-Conductor - Low Cap. Computer Cable for EIA RS-232/422/485 Applications For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) tinned copper conductors, plenum, foam FEP insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, fluorocopolymer jacket. Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 9 24 7x32 TC - Tinned Copper Total Number of Conductors: 18 Insulation Insulation Material: Insulation Material Wall Thickness (in.) FFEP - Foam Fluorinated Ethylene Propylene 0.015 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVDF - Fluorocopolymer 0.014 Overall Cable Overall Nominal Diameter: 0.352 in. Pair Pair Color Code Chart: Number Color 1 White/Blue & Blue/White 2 White/Orange & Orange/White 3 White/Green & Green/White 4 White/Brown & Brown/White 5 White/Gray & Gray/White 6 Red/Blue & Blue/Red 7 Red/Orange & Orange/Red 8 Red/Green & Green/Red 9 Red/Brown & Brown/Red Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +150C Bulk Cable Weight: 65 lbs/1000 ft. Max. Recommended Pulling Tension: 104 lbs. Min. Bend Radius/Minor Axis: 3.750 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes Page 1 of 3 09-11-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 88109 Multi-Conductor - Low Cap. Computer Cable for EIA RS-232/422/485 Applications EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: NFPA 262 CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 100 Nom. Inductance: Inductance (H/ft) 0.21 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 12.95 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 23.3 Nominal Velocity of Propagation: VP (%) 78 Nominal Delay: Delay (ns/ft) 1.3 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 24 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 13 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 1.1 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 88109 0081000 1,000 FT 74.000 LB GRAY C 9 24 PR FS SOLEF 88109 008500 500 FT 36.500 LB GRAY C 9 24 PR FS SOLEF Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 09-20-2012 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. Page 2 of 3 09-11-2017