Product: 88232 Triax, RG59, 20 AWG Solid BC, Double 95% BC Braids, FEP Jkt, CMP Product Description Triax, RG59 20 AWG, Solid Bare Copper Conductor, FEP Insulation, 95% Bare Copper Braid Shield, FEP Insulation, 95% Bare Copper Braid Shield, FEP Jacket, CMP Technical Specifications Product Overview Suitable Applications: Analog Video Interconnect camera to CCU (camera control unit) Construction Details RG Type: 59 Conductor Size Stranding Nom. Diameter Material 20 AWG Solid 0.034 in BC - Bare Copper Insulation Material Nom. Insulation Diameter FEP - Fluorinated Ethylene Propylene (Foam) 0.140 in (3.56 mm) Inner Shield Layer Shield Type Material Coverage 1 Braid Bare Copper (BC) 95% Inner Jacket Material Nom. Diameter FEP - Fluorinated Ethylene Propylene 0.188 in (4.78 mm) Outer Shield Layer Outer Shield Type Material Coverage 1 Braid Bare Copper (BC) 95% Outer Jacket Material Nom. Diameter FEP - Fluorinated Ethylene Propylene 0.245 in (6.22 mm) Overall Cable Diameter (Nominal): 0.245 in (6.22 mm) Electrical Characteristics Return Loss (RL) Frequency Min. Return Loss 5 - 850 MHz 21 dB 850 - 3000 MHz 15 dB Attenuation Frequency Nom. Attenuation 1 MHz 0.40 dB/100ft3.6 MHz 0.60 dB/100ft 10 MHz 0.80 dB/100ft 71.5 MHz 2.20 dB/100ft 135 MHz 3.10 dB/100ft 270 MHz 4.50 dB/100ft 360 MHz 5.30 dB/100ft 540 MHz 6.60 dB/100ft 720 MHz 7.70 dB/100ft 750 MHz 7.90 dB/100ft 1000 MHz 9.40 dB/100ft 1500 MHz 12.10 dB/100ft 2250 MHz 15.60 dB/100ft 3000 MHz 18.70 dB/100ft Electricals Nom. Conductor DCR Nom. Inner Shield DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop. 10.0 Ohm/1000ft (32.8 2.6 Ohm/1000ft (8.5 Ohm/km) 2.6 Ohm/1000ft (8.5 Ohm/km) 16.9 pF/ft (55.4 pF/m) 75 Ohm 80% Ohm/km) Voltage UL Voltage Rating 300 V (CMP) Mechanical Characteristics Temperature UL Temperature Operating 200C -40C to +200C Bend Radius Installation Min. 2.5 in Max. Pull Tension: 106 lbs (48.1 kg) Bulk Cable Weight: 58 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor - Plenum, Indoor Sustainability: CA Prop 65 Flammability / Reaction to Fire: NFPA 262, FT6 NEC / UL Compliance: CMP CEC / C(UL) Compliance: CMP European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Non-Plenum Number: 8232A History Update and Revision: Revision Number: 0.323 Revision Date: 12-15-2021 Variants Item Color Putup Type Length UPC 88232 010500 Black Reel 500 ft 612825216902 88232 0101000 Black Reel 1,000 ft 612825216889 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.