Product: 88760
Electronic, 2 C #18 Str TC, FEP Ins, OS, FEP Jkt, CMP
Product Description
High Temperature Electronic, 2 Conductor 18AWG (19x30) Tinned Copper, FEP Insulation, Overall Beldfoil Shield, FEP Outer Jacket, CMP
Technical Specifications
Product Overview
extreme high/low temperature environments; chemical resistant; outdoor and burial applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, );
Suitable Applications:
line level audio; wet locations; panel wiring
Construction Details
Conductor
Element Number of Element AWG Stranding Material
Pair(s) 1 18 19x30 TC - Tinned Copper
Insulation
Element Material Thickness [in.] Color Code
Pair(s) FEP - Fluorinated Ethylene Propylene 0.007 Black, Red
Outer Shield Material
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (7x28) TC
Outer Jacket Material
Material Thickness Nom. Diameter
FEP - Fluorinated Ethylene Propylene 0.014 in 0.146 in
Cable Diameter (Nominal): 0.146 in
Electrical Characteristics
Electricals
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Characteristic Impedence Max. Current
Pair(s) 5.5 Ohm/1000ft 51 pF/ft 97 pF/ft 29 Ohm 5.4 Amps per Conductor at 25C
Nom Outer Shield DCR: 7.3 Ohm/1000ft
Voltage
UL Voltage Rating
300 V (CMP)
Mechanical Characteristics
Temperature
Operating
-70C to +200C
Bend Radius
Stationary Min. Installation Min.1.5 in 1.5 in
Max. Pull Tension: 62 lbs
Bulk Cable Weight: 23 lbs/1000ft
Standards and Compliance
Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Oil Resistance, Burial
Flammability / Fire
UL1685 FT4 Loading, FT4, IEC 60332-1-2
Resistance:
NEC / UL Compliance: Article 800, CMP
CEC / C(UL) Compliance: CMP
CPR Euroclass: Eca
European Directive
EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE)
Compliance:
Non-Plenum Number: 8760
Product Notes
Notes: For use in indoor plenum environments but also suitable for outdoor and underground applications. Gas/vapor-tight jacket.
History
Update and Revision: Revision Number: 0.359 Revision Date: 08-25-2020
2020 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.