Product: 9116SB Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, LSZH Jkt, CMG-LS, ABS Certified Product Description Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Foil + 60% Aluminum Braid Shield, LSZH Jacket, CMG-LS, Shipboard ABS Type Approved Technical Specifications Product Overview Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas, ABS approved for marine shipboard and offshore use Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 18 Solid BCCS - Bare Copper Covered Steel 0.04 in 1 Conductor Count: 1 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.18 in Table Notes: Gas Injected Color Chart Color White Outer Shield Type Layer Material Material Trade Name Coverage % Tape 1 Tri-Laminate (Alum+Poly+Alum) Duobond II 100% Braid 2 Aluminum 57% Outer Jacket Material Nominal Diameter PO - Polyolefin 0.274 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Conductor DCR Conductor Resistance Nominal Outer Shield DCR Outer Conductor DCR 28 Ohm/1000ft 28 Ohm/1000ft 9 Ohm/1000ft 9 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 16.2 pF/ft Inductance Nominal Inductance 0.097 H/ftImpedance Nominal Characteristic Impedance 75 Ohm Return Loss (RL) Frequency MHz Min. Structural Return Loss (SRL) 5-1000 MHz 20 dB 1000-2250 MHz 15 dB 2250-3000 MHz 10 dB Delay Nominal Delay Nominal Velocity of Propagation (VP) % 1.2 ns/ft 83% High Frequency Frequency MHz Max. Insertion Loss (Attenuation) 5 MHz 0.67 dB/100ft 55 MHz 1.6 dB/100ft 211 MHz 2.87 dB/100ft 270 MHz 3.24 dB/100ft 300 MHz 3.43 dB/100ft 350 MHz 3.72 dB/100ft 400 MHz 4 dB/100ft 450 MHz 4.26 dB/100ft 550 MHz 4.71 dB/100ft 750 MHz 5.59 dB/100ft 870 MHz 6 dB/100ft 1000 MHz 6.54 dB/100ft 1450 MHz 8.3 dB/100ft 1800 MHz 9.3 dB/100ft 2250 MHz 10.6 dB/100ft 3000 MHz 11.9 dB/100ft Voltage UL Voltage Rating 300 V RMS Temperature Range Operating Temp Range: -20C To +75C Mechanical Characteristics Bulk Cable Weight: 28 lbs/1000ft Max. Pull Tension: 126 lbs Min. Bend Radius During Installation: 2.75 in Min. Bend Radius/Minor Axis: 2.75 in Standards NEC/(UL) Compliance: CMG-LS CEC/C(UL) Compliance: CMG-LS IEEE Compliance: Std. 45 clause 23 Series Type: 6 Other Specification: UL444, ABS Type Approval Certificate 05-HS500072C Applicable Environmental and Other Programs Environmental Space: Indoor/Outdoor EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes