Product: 9318 High Perform Instr, 1 Pr 18 Str TC, PVC Ins E2, OS, PVC Jkt, PLTC-ER Product Description High Performance Instrumentation, 1 Pair 18AWG (19x30) Tinned Copper, PVC Insulation E2 Color Code, Overall Beldfoil Shield, PVC Outer Jacket, PLTC-ER Technical Specifications Product Overview Suitable Applications: Instrumentation, Sensors, Valves, Positioners, 4-20mA, 0-10V Construction Details Conductor Element Number of Element Size Stranding Material Pair(s) 1 18 AWG 19x30 TC - Tinned Copper Insulation Element Material Nom. Thickness Color Code Pair(s) PVC - Polyvinyl Chloride 0.017 in (0.43 mm) Black, Red Outer Shield Shield Type Material Coverage Drainwire Type Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (19x32) TC Outer Jacket Material Nom. Thickness Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.037 in (0.94 mm) 0.239 in (6.07 mm) Yes Overall Cable Diameter (Nominal): 0.239 in (6.07 mm) Electrical Characteristics Electricals Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Shield Max. Current Pair(s) 6.0 Ohm/1000ft (20 Ohm/km) 54 pF/ft (180 pF/m) 100 pF/ft (330 pF/m) 5.5 Amps per Conductor at 25C Voltage UL Voltage Rating 300 V (PLTC, CMG), 150 V (ITC) Mechanical Characteristics Temperature UL Temperature Operating 105C -30C to +105C Table Notes: AWM 80C Bend Radius Stationary Min. Installation Min.2.4 in (61 mm) 2.4 in (61 mm) Max. Pull Tension: 64 lbs Bulk Cable Weight: 32 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance Flammability / Reaction to Fire: UL1685 UL Loading, FT4, T-29-520, 1202 NEC / UL Compliance: Article 725, Article 727, Article 800, CMG, ITC-ER, PLTC-ER AWM Compliance: 2464 CEC / C(UL) Compliance: CMG European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) History Update and Revision: Revision Number: 0.390 Revision Date: 12-15-2021 Variants Item Color UPC 9318 0601000 Chrome 612825228615 9318 06010000 Chrome 612825228622 9318 06015000 Chrome 612825228639 9318 0605000 Chrome 612825228646 9318 060U1000 Chrome 612825228592 9318 060U500 Chrome 612825228608 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.