General Description:
18 AWG stranded (19x30) tinned copper conductors, conductors cabled, semi-rigid PVC insulation, overall
Beldfoil shield (100% coverage), 20 AWG stranded tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
4 18 19x30 TC - Tinned Copper
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
S-R PVC - Semi-Rigid Polyvinyl Chloride .011
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil (Z-Fold) Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 Stranded TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .035
Overall Cable
Overall Cabling Lay Length & Direction:
Length (in.) Direction Twists (twist/ft)
2.000 Left Hand 6.000
Overall Cabling Color Code Chart:
Number Color
1 Red
2 Green
3 Black
4 White
Overall Nominal Diameter: 0.245 in.
Mechanical Characteristics (Overall)
Operating Temperature Range: -20C To +80C
UL Temperature Rating: 80C (UL AWM Style 2464)
Bulk Cable Weight: 42 lbs/1000 ft.
Max. Recommended Pulling Tension: 100 lbs.
Min. Bend Radius/Minor Axis: 2.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG
NEC Articles: 800
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2464 (300 V 80C)
Page 1 of 3 01-05-2017Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9418 Multi-Conductor - Audio, Control and Instrumentation Cable
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
CSA Flame Test: FT4
Suitability
Suitability - Indoor: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 89418 or 82418
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
40.000
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
72.000
Nom. Conductor DC Resistance:
DCR @ 20C (Ohm/1000 ft)
6.5
Nominal Outer Shield DC Resistance:
DCR @ 20C (Ohm/1000 ft)
8.5
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Description Current
10C Temperature rise 5 Amps per conductor @ 25C ambient
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9418 060U1000 1,000 FT 45.000 LB CHROME 4 #18 PVC FS FRPVC
9418 060U500 500 FT 23.500 LB CHROME 4 #18 PVC FS FRPVC
9418 060100 100 FT 5.100 LB CHROME 4 #18 PVC FS FRPVC
9418 0601000 1,000 FT 45.000 LB CHROME C 4 #18 PVC FS FRPVC
9418 06010000 10,000 FT 500.000 LB CHROME C Y 4 #18 PVC FS FRPVC
9418 06013000 13,000 FT 585.000 LB CHROME C Y 4 #18 PVC FS FRPVC
9418 060500 500 FT 23.500 LB CHROME C 4 #18 PVC FS FRPVC
9418 0605000 5,000 FT 230.000 LB CHROME C Z 4 #18 PVC FS FRPVC
Notes:
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 4 Revision Date: 08-02-2013
2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Page 2 of 3 01-05-2017