Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9451 Multi-Conductor - Single-Pair Cables For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 1 22 7x30 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PP - Polypropylene .008 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 22 7x30 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .020 Overall Cable Overall Nominal Diameter: 0.135 in. Pair Pair Color Code Chart: Number Color 1 Black & Red Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 60C Bulk Cable Weight: 14 lbs/1000 ft. Max. Recommended Pulling Tension: 27 lbs. Min. Bend Radius/Minor Axis: 1.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes Page 1 of 3 01-05-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9451 Multi-Conductor - Single-Pair Cables EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Vertical Shaft CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 45 Nom. Inductance: Inductance (H/ft) .17 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 35 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 67 Nominal Velocity of Propagation: VP (%) 66 Nominal Delay: Delay (ns/ft) 1.5 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 14.1 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 14.3 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.9 Amps per conductor 25C Notes (Overall) Notes: The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. For cross-connect use with 1814R (et. al.) Snake Cables. Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 9451 N3UU1000 1,000 FT 16.000 LB GREEN, MIL 2 22 PP FS PVC FR 9451 N3U5000 5,000 FT 70.000 LB GREEN, MIL C N 2 22 PP FS PVC FR 9451 001U1000 1,000 FT 16.000 LB BROWN 2 22 PP FS PVC FR 9451 0015000 5,000 FT 70.000 LB BROWN C N 2 22 PP FS PVC FR 9451 002N1000 1,000 FT 18.000 LB RED 2 22 PP FS PVC FR 9451 002U1000 1,000 FT 16.000 LB RED 2 22 PP FS PVC FR 9451 0025000 5,000 FT 75.000 LB RED C N 2 22 PP FS PVC FR 9451 003U1000 1,000 FT 16.000 LB ORANGE 2 22 PP FS PVC FR 9451 0035000 5,000 FT 75.000 LB ORANGE C N 2 22 PP FS PVC FR 9451 004N1000 1,000 FT 18.000 LB YELLOW 2 22 PP FS PVC FR 9451 004U1000 1,000 FT 16.000 LB YELLOW 2 22 PP FS PVC FR 9451 0045000 5,000 FT 75.000 LB YELLOW C N 2 22 PO FS PVC FR 9451 006U1000 1,000 FT 16.000 LB BLUE, LIGHT 2 22 PP FS PVC FR 9451 0065000 5,000 FT 75.000 LB BLUE, LIGHT C N 2 22 PP FS PVC FR Page 2 of 3 01-05-2017