Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9502 Multi-Conductor - Computer Cable for EIA RS-232 Applications For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain Wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 2 24 7x32 TC - Tinned Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (in.) S-R PVC - Semi-Rigid Polyvinyl Chloride 0.011 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride 0.032 Overall Cable Overall Nominal Diameter: 0.222 in. Pair Pair Color Code Chart: Number Color 1 Black & Red 2 Black & White Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +80C UL Temperature Rating: 80C (UL AWM Style 2464) Bulk Cable Weight: 26 lbs/1000 ft. Max. Recommended Pulling Tension: 22 lbs. Min. Bend Radius/Minor Axis: 2.250 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2464 (300 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 01-05-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9502 Multi-Conductor - Computer Cable for EIA RS-232 Applications EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes PMSHA Specification: SC-7K-182037 Other Specification: CSA AWM I/II, A Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Suitability Sunlight Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 82502 Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) 0.190 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 30 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 50 Nominal Velocity of Propagation: VP (%) 60 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 24 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 17 Max. Operating Voltage - UL: Voltage 300 V RMS (UL AWM Style 2464) Max. Recommended Current: Current 1.76 Amps per conductor 25C Notes (Overall) Notes: Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration certification. Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 9502 060U1000 1,000 FT 23.000 LB CHROME 2 PR 24 PVC FS PVC 9502 060U500 500 FT 12.000 LB CHROME 2 PR 24 PVC FS PVC 9502 060100 100 FT 2.800 LB CHROME 2 PR 24 PVC FS PVC 9502 0601000 1,000 FT 30.000 LB CHROME C 2 PR 24 PVC FS PVC 9502 06010000 10,000 FT 290.000 LB CHROME C Y 4 24 PVC PVC 9502 060500 500 FT 12.000 LB CHROME C 2 PR 24 PVC FS PVC 9502 0605000 5,000 FT 110.000 LB CHROME C Z 2 PR 24 PVC FS PVC Notes: C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500 . Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Page 2 of 3 01-05-2017