Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9537 Multi-Conductor - Computer Cable for EIA RS-232 Applications For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) tinned copper conductors, conductors cabled, semi-rigid PVC insulation, overall Beldfoil shield (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 7 24 7x32 TC - Tinned Copper Total Number of Conductors: 7 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PVC - Polyvinyl Chloride 0.011 Outer Shield Outer Shield Material: Outer Shield Trade Name Outer Shield Material Coverage (%) Beldfoil Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .032 Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 White 3 Red 4 Green 5 Brown 6 Blue 7 Orange Overall Nominal Diameter: 0.209 in. Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +80C UL Temperature Rating: 80C (UL AWM Style 2464) Bulk Cable Weight: 28 lbs/1000 ft. Max. Recommended Pulling Tension: 38.500 lbs. Min. Bend Radius/Minor Axis: 2.250 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2464 (300 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes Page 1 of 2 01-05-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9537 Multi-Conductor - Computer Cable for EIA RS-232 Applications EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 33 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 65 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 25 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 18 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 1.75 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 9537 060U1000 1,000 FT 29.000 LB CHROME 7 24 PVC FS PVC 9537 060U500 500 FT 15.500 LB CHROME 7 24 PVC FS PVC 9537 060100 100 FT 3.500 LB CHROME C 7 24 PVC FS PVC 9537 0601000 1,000 FT 31.000 LB CHROME C 7 24 PVC FS PVC 9537 060500 500 FT 15.500 LB CHROME C 7 24 PVC FS PVC 9537 0605000 5,000 FT 145.000 LB CHROME C 7 24 PVC FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 09-07-2012 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 01-05-2017