Type 0ADAC / 0ADAP Fast-Acting Fuse Series 0ADAC/0ADAP Series, 6x32mm Ceramic Tube Fast-Acting Fuse RoHS Compliant Description A 600VAC/VDC rated ceramic tube in a compact, 6.3 x 32mm package designed for circuit protection in high energy and high voltage applications. Features - Fast-acting, high breaking capacity up to 600Vac/dc - Available in cartridge and pigtail axial lead - Designed to UL 248-1 - Full compliance with EU Directive 2011/65/EU and amending directive 2015/863 - Halogen Free - Lead Free Applications - Digital Measuring Instruments - Industrial Power Supplies - DC/DC modules - Power Inverters LEAD FREE = - UPS HALOGEN FREE = - Smart Meters - 3 phase Physical Specifications Body : Ceramic Materials Cap: Silver Plated Caps Pigtail Leads: Tin Plated Copper On Fuse : bel 0ADACurrent Rating, Voltage Rating, Appropriate Safety Logos On Label : Marking be,0ADACor0ADACurrent RatinVoltage RatinInterrupting Ratin, Appropriate Safety Logo and , (China RoHS compliant). Electrical Characteristics Safety Agency Approvals Safety Safety Voltage Rating Ampere Range / Volt Agency Testing Current Opening Time Agency (V) I.R. ability* Certificate 200mA 12A / 600V 10KA AC 100% 4 hour Min. E20624 200mA 12A 600V AC/DC / 600V 10KA DC 250% 120 sec Max. *I.R.= Interrupting Rating = Short Circuit Rating(Amps) Specifications subject to change without notice belfuse.com/circuit-protection 2 / 4 Type 0ADAC /0ADAP Environmental Specifications Operating Temperature -50 to +105 Terminal Strength MIL-STD-202G, Method 211 Test Condition A Lead Solderability MIL-STD-202, Method 208 Mechanical Vibration MIL-STD-202, Method 201 Thermal Shock MIL-STD-202, Method 107 Test Condition B (5 cycles -65 to +125 ) Humidity MIL-STD-202, Method 103, Test Condition A ( 95%RH and 40 for 240 hours ) Electrical Specifications Part Number Ampere Typical Cold Resistance Voltage and Interrupting Typical Pre Arcing It Typical Voltage Drop (For bulk) Rating (mOhms) Ratings (A Sec) ( mV) 0ADAx0200-xx 200mA 3900 850 0.003 0ADAx0250-xx 250mA 2755 828 0.009 0ADAx0315-xx 315mA 1900 568 0.030 0ADAx0400-xx 400mA 1875 890 0.038 0ADAx0500-xx 500mA 1160 616 0.041 0ADAx0600-xx 600mA 1035 765 0.072 0ADAx1000-xx 1A 450 553 0.23 0ADAx1600-xx 1.6A 160 307 0.89 See Table of Ratings on 0ADAx2000-xx 2A 155 381 1.28 Page 1 for Voltage and associated Interrupting 0ADAx2500-xx 2.5A 89 275 3.91 Ratings 0ADAx3000-xx 3A 64 218 7.74 0ADAx3150-xx 3.15A 60 230 9.92 0ADAx4000-xx 4A 44 223 15.50 0ADAx5000-xx 5A 33 221 26.50 0ADAx6000-xx 6A 26 214 41.76 0ADAx8000-xx 8A 18 203 76.80 0ADAx9100-xx 10A 16.8 242 101.40 0ADAx9120-xx 12A 12.8 233 187.20 Consult manufacturer for other ratings *DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25 2 *Typical Pre-arcing I t are measured at 10In Current Specifications subject to change without notice Bel Fuse Inc. +1 201.432.0463 206 Van Vorst Street Bel.US.CS belf.com Jersey City, NJ 07302 USA belfuse.com/circuit-protection 2021 Bel Fuse, Inc. Rev. 0ADAC/0ADAP May2021