The 0RCY-60U12C is an isolated DC/DC converter that operate from a wide input range (18 - 75 VDC) and can cover both 24 Vin and 48 Vin input range. These units will provide up to 84 W of output power. They are designed to be highly efficient and low cost. Features include remote on/off, over current protection, over voltage shut down, over temperature protection and under-voltage lockout. These converters are provided in an industry standard 1/8th brick package. 18 - 75 VDC Input 12 VDC / 7 A Output Isolated Fixed Frequency (258 kHz) High Efficiency High Power Density Input Under/Over Voltage Lockout Output Voltage Trim Basic Isolation Output Over-Voltage Shutdown Low Cost Positive / Negative Remote Sense OCP/SCP Over Temperature Protection Remote On/Off Approved to IEC/EN 60950-1 Approved to IEC/EN 62368-1 Approved to UL/CSA 60950-1 Class II, Category 2, Isolated DC/DC Converter (refer to IPC-9592B) Networking Computers and peripherals Telecommunications 2 0RCY-60U12C MODEL OUTPUT INPUT MAX. OUTPUT MAX. OUTPUT TYPICAL NUMBER VOLTAGE VOLTAGE CURRENT POWER EFFICIENCY 0RCY-60U12CG 12 VDC 18 - 75 VDC 7 A 84 W 92% 0 R CY - 60 U 12 C G RoHS Output Input Output Mounting Type Series Name Active Logic Package Type Status Power Range Voltage Through Hole th RoHS 1/8 Brick 84 W 18 75 V 12 V Active Low, with Baseplate Tray Package Mount PARAMETER DESCRIPTION MIN TYP MAX UNITS Input Voltage (Continuous) -0.3 - 80 V Input Transient Voltage 100 ms maximum - - 100 V Remote On/Off -0.3 - 18 V I/O Isolation Voltage - - 1500 V Ambient Temperature -40 - 85 C Storage Temperature -55 - 125 C Altitude - - 2000 m NOTE: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the device. All specifications are typical at 25C unless otherwise stated. PARAMETER DESCRIPTION MIN TYP MAX UNIT Input Voltage 18 24 / 48 75 V Input Current (full load) - - 6.7 A Input Current (no load) - 100 180 mA Remote Off Input Current 10 15 mA With simulated source impedance of 10 H, Input Reflected Ripple Current (pk-pk) - 15 30 mA 5 Hz to 20 MHz. Use a 100 F/100 V electrolytic capacitor with ESR = 1 ohm max, Input Reflected Ripple Current (rms) - 5 10 mA at 200 kHz 25C. 2 2 I t Inrush Current Transient - 0.05 0.1 A s Turn-on Voltage Threshold 16.0 17.0 17.5 V Turn-off Voltage Threshold 15.0 16.0 16.5 V Input Over Voltage Lockout 76 78 80 V CAUTION: This converter is not internally fused. An input line fuse must be used in application. Recommend a fast-acting fuse with max. rating of 8 A on system board. Refer to the fuse manufactures datasheet for further information. NOTES: 1. This converter has internal C-L-C (2.2 uH-2*0.47 uF+2.2 uF) filter. 2. All specifications are typical at 25 C unless otherwise stated. tech.support psbel.com