The 0RQB-30Y05L is an isolated DC/DC converter providing 30 W of output power from a wide input range (24 V, 48 V, 72 V, 96 V, 110 V typical). Standard features include remote on/off, input under-voltage protection, output over-voltage protection, over current and short circuit protection. This converter can also provide a 5 V/5 mA auxiliary supply. When a large hold-up capacitor is added, the converter can still work up to 12 ms when the input supply is interrupted. Conformal coated PCB is used for environmental ruggedness. 24 / 48 / 72 / 96 / 110 VDC Input 5 VDC / 6 A Output Reinforced Isolation Input Under-Voltage Protection High Efficiency Output Over-Voltage Protection Hold-up Function Over Current and Short Circuit Protection Remote ON/OFF Over Temperature Protection Conformal Coated 5V Auxiliary Supply at Primary Side Wide Input Range (24 V,48 V,72 V,96 V,110 V typical) Approved to EN 62368-1 Class II, Category 2, Isolated DC/DC Converter (refer to IPC-9592B) Industrial Railway 0RQB-30Y05L 2 MODEL NUMBER OUTPUT INPUT MAX. OUTPUT MAX. OUTPUT TYPICAL ACTIVE LOW VOLTAGE VOLTAGE CURRENT POWER EFFICIENCY 0RQB-30Y05LG 5 VDC 24 / 48 / 72 / 96 / 110 VDC 6 A 30 W 82% 0 R QB - 30 Y 05 L G RoHS Output Output Active Logic & HSK Package Mounting Type Series Name Input Range Status Power Voltage Feature Type Through Hole DOSA Quarter Active Low, Tray RoHS 30 W 24 / 48 / 72 / 96 / 110 V 5 V Mount Brick with Baseplate Package PARAMETER DESCRIPTION MIN TYP MAX UNITS Continuous non-operating Input Voltage 0.5 - 160 V Remote On/Off -0.3 - 15 V Baseplate to heatsink, flat greased surface 0.24 - - Thermal Resistance C/W Baseplate to ambient - 4 - Operating Temperature Temp. measured at the center of the baseplate, full load -40 - 105 C Storage Temperature -55 - 125 C Altitude - 2000 m - NOTE: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the device. PARAMETER DESCRIPTION MIN TYP MAX UNIT 24 48 Operating Input Voltage Range 1 Fully functioning for long term operation. 16.8 72 137.5 V 96 110 Fully functioning for 0.1 s operation. 12.9 - 16.8 Operating Input Voltage Range 2 Full function is not guaranteed but undamaged for V 137.5 - 154 1 s operation. Input Current - - 3.0 A Input Voltage Rising Slope - - 2 V/ms Input Current (no load) - 100 150 mA Remote Off Input Current - - 40 mA With simulated source impedance of 10 H, Input Reflected Ripple Current (pk-pk) - - 300 mA 5 Hz to 20 MHz. Use two 100 F/250 V electrolytic capacitors with ESR = 0.5R max, at 200 kHz Input Reflected Ripple Current (rms) - - 100 mA 25C. Under-voltage Turn on Threshold Lockout turn on 14.5 15.2 16 V Under-voltage Turn off Threshold Lockout turn off, non-latching 11.7 12.2 12.7 V Recommended input fast-acting fuse CAUTION: This converter is not internally fused. An - 6 - V on system board input line fuse must be used in application. tech.support psbel.com