50 Ohm SMC Straight Crimp Type Bulkhead Jack - INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Captivated Contact CABLE TYPE GOLD PLATED NICKEL PLATED RG-316 DS, 188 DS 131-6304-401 131-6304-406 CABLE PART CRIMP GROUP NUMBER HEX RG-316DS, 188DS 131-6304-401/406 .151 (3.83) 1. Identify connector parts. (2 piece parts - except bulkhead) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. A wire stripper of correct size is rec- ommended for this step. Twist stranded center conduc- tor into tight bundle and tin. Slide crimp sleeve onto cable as shown. 3. Flare braid and slide cable into body making certain that the cable insulation bottoms in center contact. Solder Attachment: Solder center conductor to contact through the side access ports and hole in center contact. Use a minimum amount of solder for a full fillet joint020 (0.51) diameter solder is recommended. Crimp 50 Ohm connector contacts with 141-0000-911 dieset in 144-900 tool frame. Crimp 75 Ohm connector contacts with 141-0000-924 dieset in 144-0000-900 tool frame. Emerson Network Power Connectivity Solutions 299 Johnson Avenue SW, Waseca, MN 56093 800 -247- 8256 +1 (507) 833-8822 www.EmersonConnectivity.comSMC - 50 Ohm Connectors Specifications INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST ELECTRICAL RATINGS RF High Potential Withstanding Voltage: (Vrms minimum, tested at Impedence: 50 ohms 4 and 7 MHz) Frequency Range: 0-10 GHz Connectors for RG-178 ........................................................................... 500 VSWR: (f = GHz) Straight Cabled Right Angle Cabled Connectors for RG-316 ........................................................................... 700 RG-178 cable ................................... 1.25 + .04f 1.40 + .06f Uncabled receptacles and adapters ........................................................ 600 RG-316 and .086 semi-rigid MECHANICAL RATINGS cable ............................................. 1.20 + .04f 1.30 + .04f Engagement Design: MIL-C-39012, Series SMC Uncabled receptacles ............................ N/A Engagement/Disengagment Force: 16 inch-ounce maximum torque Adapters ........................................... 1.20 + .04f Mating Torque: 35 to 50 inch-ounce Coupling Proof Torque: 100 inch-ounce minimum Working Voltage: (Vrms maximum) Coupling Nut Retention: 35 pounds minimum Connectors for Cable Type Sea Level 70K Feet Contact Retention: 4 lbs. minimum axial force (captivated contacts) RG-178 ............................................... 250 60 1 inch-ounce minimum torque (uncabled receptacles) RG-316, .086 semi-rigid Cable Retention: Axial Force* Torque uncabled receptacles, adapters ........ 335 85 (pounds) (in-oz) Dielectric Withstanding Voltage: (VRMS minimum at sea level) Connectors for RG-178 ...................................... 10 N/A Connectors for RG-178 ........................................................................... 750 Connectors for RG-316 ...................................... 20 N/A Connectors for RG-316, .086 semi-rigid Connectors for .086 semi-rigid ........................... 30 16 uncabled receptacles, adapters ........................................................... 1000 * or cable breaking strength whichever is less Corona Level: (Volts minimum at 70,000 feet) Durability: 500 cycles minimum Connectors for RG-178 ........................................................................... 185 ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph of Connectors for RG-316, .086 semi-rigid .................................................. 250 MIL-C-39012 Uncabled receptacles and adapters ........................................................ N/A Temperature Range: - 65C to + 165C Insertion Loss: (dB maximum, tested at 4 GHz) Thermal Shock: MIL-STD-202, Method 107, Condition B Straight cable connectors .................................................................. 0.25 dB Corrosion: MIL-STD-202, Method 101, Condition B Right angle cable connectors ............................................................ 0.50 dB Shock: MIL-STD-210, Method 213, Condition C Uncabled receptacles and adapters ........................................................ N/A Vibration: MIL-STD-202, Method 204, Condition D Insulation Resistance: 1000 megohms minimum MATERIAL SPECIFICATIONS Contact Resistance: (milliohms maximum) After Bodies: Brass per QQ-B-626, gold plated** per MIL-G-45204 .00001 min or Initial Environmental nickel plated per QQ-N-290 Center contact (straight cabled Contacts: Male - brass per QQ-B-626, gold plated per MIL-G-45204 connectors and uncabled receptacles) .............. 6.0 8.0 .00003 min. Center contact (right angle cabled Female - beryllium copper per QQ-C-530, gold plated per MIL-G-45204 connectors and adapters) ................................ 12.0 16.0 .00003 min. Outer contact (gold plated connectors) ................. 1.0 N/A Nut Retention Spring: Beryllium copper per QQ-C-533, unplated Outer contact (nickel plated connectors) .............. 2.5 N/A Insulators: PTFE fluorocarbon per ASTM D 1710 and ASTM D 1457 Braid to body (gold plated connectors) ................. 1.0 N/A Expansion Caps: Brass per QQ-B-613, gold plated per MIL-G-45204 .00001 Braid to body (nickel plated connectors) ............... 2.5 N/A min. or nickel plated per QQ-N-290 RF Leakage: (dB minimum tested at 2.5 GHz) Crimp Sleeves: Copper per WW-T-799, gold plated per MIL-G-45204 .00001 Cable connectors ............................................................................... -55 dB min. or nickel plated per QQ-N-290 Uncabled receptacles and adapters ........................................................ N/A Mounting Hardware: Brass (nuts) per QQ-B-626 or phosphor bronze (lockwashers) per QQ-B-750, gold plated per MIL-G-45204 .00001 min. or ** All gold plated parts inlcude a .00005 min. nickel underplate barrier layer. nickel plated per QQ-N-290 Avoid user injury due to misapplication. See safety advisory definitions inside front cover. MATING ENGAGEMENT FOR SMC SERIES PER MIL-C-39012 JACK PLUG NOTES 1. Inside of contact to meet VSWR, mating charac- PLUG JACK teristics and connector durability when mated with a dia .019/.021 (0.48/0.53) male contact. Emerson Network Power Connectivity Solutions 299 Johnson Avenue SW, Waseca, MN 56093 800 -247- 8256 +1 (507) 833-8822 www.EmersonConnectivity.com