MCX Non-Magnetic RF Connectors INCHES (MILLIMETERS) For Flexible Cable CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Straight Crimp Type Plug - Solder or Crimp Contact - Captivated Contact CABLE TYPE GOLD PLATED 133-9403-001 RG-316/u, 188, 174 MCX Crimp Type Straight Connectors CABLE GROUP PART NUMBER CRIMP HEX RG-316/u, 188, 174 133-9403-001 .128 (3.25) For Flexible Cable RG-316DS, 188DS 133-9404-001 .151 (3.83) 1. Identify connector parts. (3 piece parts) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. Tin center conductor if contact is to be solder attached. Do not tin center conductor if contact is to be crimp attached. Slide heat shrink (as applicable) and crimp sleeve onto jacket of cable. 3. Assemble contact onto cable as shown. Solder attachment. Solder contact to center conductor through solder hole using .020 (0.51) diameter solder. Use a minimum of solder for a good joint. TM Crimp attachment. Crimp contact to center conductor using Johnson Components hand tool 140- 0000-952 and die set 140-0000-953. Crimp location should be centered between end of contact and cross hole. Crimp attachment to solid center conductor cable is not recommended. 4. Flair braid and slide body assembly over contact and under braid. Then seat body assembly firmly onto contact. The cable may have to be held in a clamping fixture. Arrange braid uniformly around crimp stem. Slide crimp sleeve forward and crimp using recommended crimp tool. Slide heat shrink forward and shrink (as applicable). 1 CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om MCX Non-Magnetic RF Connectors INCHES (MILLIMETERS) Specifications CUSTOMER DRAWINGS AVAILABLE UPON REQUEST SPECIFICATIONS ELECTRICAL RATINGS RF Leakage: (dB typical tested at 2.5 GHz) Impedance: 50 Ohms Cable connectors ...................................................................................... -55 Frequency Range: 0-6 GHz Uncabled receptacles ............................................................................... N/A VSWR: (f = GHz) Straight Cabled Right Angle RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 and 7 Connectors Cabled Connectors MHz) RG-316 cable ............................................ 1.13 + .04f 1.07 + .04f Cabled connectors ................................................................................... 700 Uncabled receptacles .................................................................................. N/A Uncabled receptacles ............................................................................... 600 Working Voltage: (Vrms maximum) MECHANICAL RATINGS Connectors for Cable Type Sea Level 70K Feet Engagement Design: Compatible with CECC 22220, Series MCX RG-316 ............................................................ 335 85 Engagement Force: 5.6 pounds maximum axial force Dielectric Withstanding Voltage: (VRMS minimum at sea level) Disengagement Force: 8 pounds maximum axial force, 1 pound min. Connectors for RG-316, uncabled receptacles ...................................... 1000 Contact Retention: 2.3 pounds min. axial force (captivated contacts) Corona Level: (Volts minimum at 70,000 feet) 1 inch-ounce min. torque (uncabled receptacles) Connectors for RG-316, uncabled receptacles ........................................ 250 Cable Retention: Axial Force* Torque Insertion Loss: (dB maximum, tested at 1 GHz) (pounds) (in-oz) Straight cable connectors .................................................................... 0.1 dB Connectors for RG316 ......................................... 20 N/A Right angle cable connectors .............................................................. 0.2 dB Connectors for RG316DS .................................... 25 N/A Uncabled receptacles ............................................................................... N/A * or cable breaking strength whichever is less. Insulation Resistance: 10,000 megohms minimum Contact Resistance: (milliohms maximum) After ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph of Initial Environmental MIL-PRF-39012) Center contact (straight cabled connectors, Durability: 500 cycles minimum uncabled receptacles) ................................................. 5.0 8.0 Temperature Range: - 65C to + 165C Center contact (right angle cabled connectors) .............. 5.0 15.0 Thermal Shock: MIL-STD-202, Method 107, Condition F Outer contact .................................................................. 1.0 1.5 Corrosion: MIL-STD-202, Method 101, Condition B Braid to body ................................................................... 1.0 N/A Shock: MIL-STD-202, Method 213, Condition B Vibration: MIL-STD-202, Method 204, Condition B Moisture Resistance: MIL-STD-202, Method 106 CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 2 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om