SMA 50 Ohm INCHES (MILLIMETERS) Straight Crimp Type Plug (3-piece) - CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Solder or Crimp Captivated Contact CABLE VSWR & GOLD NICKEL TYPE FREQ. RANGE PLATED PLATED A .706 (17.93) RG-188 DS, RG-316 DS 1.15 + .02 f (GHz) 0-12.4 GHz 142-0404-011 142-0404-016 CABLE GROUP PART NUMBER CRIMP HEX RG-316DS, 188DS 142-0404-011/016 .151 (3.83) 1. Identify connector parts. (3 piece parts - except bulkhead) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. Tin center conductor if contact will be solder attached. Do not tin center conductor if contact is to be crimp attached. When stripping LMR-100 low loss cable, remove foil back to where cabl e jacket is stripped. A wire stripper of correct size is recommended for this step. Slide heat shrink (as applicable) and crimp sleeve onto jacket of cable. 3. Assemble contact onto cable as shown. Solder Attachment: Solder contact to center conductor through solder hole using .020 (0.51) diameter solder. Use a minimum amount of solder for a good joint. TM Crimp Attachment: Crimp contact to center conductor using Johnson Components Hand Tool 144-0000-910, setting 2, with positioner 141-0000-907. Crimp location should be centered between end of contact and X-hole. Crimp attachment to solid cente r conductor cables is not recommended. 4. Flare braid and slide body assembly over contact and under braid. Then seat body assembly firmly onto contact. The cable may have to be held in a clamping fixture. Arrange braid uniformly around crimp stem. Slide crimp sleeve forward and crimp using recom mended crimp tool. Slide heat shrink forward and shrink (as applicable). CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om SMA - 50 Ohm Connectors Specifications INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST ELECTRICAL RATINGS Impedance: 50 ohms Insertion Loss: (dB maximum) Frequency Range: Straight flexible cable connectors Dummy loads .......................................................................... 0-2 GHz and adapters ...................... 0.06 f (GHz), tested at 6 GHz Flexible cable connectors ................................................... 0-12.4 GHz Right angle flexible cable Uncabled receptacles, RA semi-rigid and adapters ........... 0-18.0 GHz connectors ......................... 0.15 f (GHz), tested at 6 GHz Straight semi-rigid cable connectors and Straight semi-rigid cable field replaceable connectors ............................................... 0-26.5 GHz connectors with contact ..... 0.03 f (GHz), tested at 10 GHz VSWR: (f = GHz) Straight Right Angle Right angle semi-rigid cable Cabled Connectors Cabled Connectors connectors ......................... 0.05 f (GHz), tested at 10 GHz RG-178 cable .............................. 1.20 + .025f 1.20 + .03f Straight semi-rigid cable RG-316, LMR-100 cable .............. 1.15 + .02f 1.15 + .03f connectors w/o contact ...... 0.03 f (GHz), tested at 16 GHz RG-58, LMR-195 cable ................ 1.15 + .01f 1.15 + .02f Straight low loss flexible RG-142 cable ............................... 1.15 + .01f 1.15 + .02f cable connectors ................ 0.06 f (GHz), tested at 1 GHz LMR-200, LMR-240 cable ............ 1.10 + .03f 1.10 + .06f Right Angle low loss flexible .086 semi-rigid ............................ 1.07 + .008f 1.18 + .015f cable connectors ................ 0.15 f (GHz), tested at 1 GHz .141 semi-rigid (w/contact) .......... 1.05 + .008f 1.15 + .015f Uncabled receptacles, field replaceable, dummy loads .....................N/A .141 semi-rigid (w/o contact) ...... 1.035 + .005f Insulation Resistance: 5000 megohms minimum Jack-bulkhead jack adapter and plug-plug adapter ................. 1.05 + .01f Contact Resistance: (milliohms maximum) Initial After Environmental Jack-jack adapter and plug-jack adapter ............................... 1.05 + .005f Center contact (straight cabled connectors Uncabled receptacles, dummy loads .................................................. N/A and uncabled receptacles) ........................... 3.0* 4.0* Field replaceable (see page 59) ......................................................... N/A Center contact (right angle cabled Working Voltage: (Vrms maximum) connectors and adapters) ..............................4.0 6.0 Connectors for Cable Type Sea Level 70K Feet Field replaceable connectors ........................6.0 8.0 RG-178 ...................................................................... 170 45 Outer contact (all connectors) ...........................2.0 N/A RG-316 LMR-100, 195, 200 ..................................... 250 65 Braid to body (gold plated connectors) .............0.5 N/A RG-58, RG-142, LMR-240, .086 semi-rigid, Braid to body (nickel plated connectors) ...........5.0 N/A uncabled receptacles, .141 semi-rigid w/o contact ... 335 85 *N/A where the cable center conductor is used as a contact .141 semi-rigid with contact and adapters ................. 500 125 RF Leakage: (dB minimum, tested at 2.5 GHz) Dummy loads ................................................................................. N/A Flexible cable connectors, adapters and .141 semi-rigid Dielectric Withstanding Voltage: (VRMS minimum at sea level) connectors w/o contact ............................................................. -60 dB Connectors for RG-178 ................................................................... 500 Field replaceable w/o EMI gasket .............................................. -70 dB Connectors for RG-316 LMR-100, 195, 200 .................................. 750 .086 semi-rigid connectors and .141 semi-rigid connectors Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, with contact, and field replaceable with EMI Gasket ................ -90 dB field replaceable, uncabled receptacles ...................................... 1000 Two-way adapters ...................................................................... -90 dB Connectors for .141 semi-rigid with contact and adapters ............ 1500 Uncabled receptacles, dummy loads .............................................. N/A Connectors for .141 semi-rigid w/o contact, dummy loads .............. N/A RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 Corona Level: (Volts minimum at 70,000 feet) and 7 MHz) Connectors for RG-178 ................................................................... 125 Connectors for RG-178 ................................................................... 335 Connectors for RG-316 LMR-100, 195, 200 .................................. 190 Connectors for RG-316 LMR-100, 195, 200 .................................. 500 Connectors for RG-58, RG-142, LMR-240, 086 semi-rigid, Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact .......................... 250 .141 semi-rigid cable w/o contact, uncabled receptacles .............. 670 Connectors for .141 semi-rigid with contact and adapters .............. 375 Connectors for .141 semi-rigid with contact and adapters ............ 1000 Dummy loads ...................................................................................... N/A Power Rating (Dummy Load): 0.5 watt + 25C, derated to 0.25 watt +125C MECHANICAL RATINGS Cable Retention: Axial Force*(lbs) Torque (in-oz) Engagement Design: MIL-C-39012, Series SMA Connectors for RG-178 ............................ 10 N/A Engagement/Disengagement Force: 2 inch-pounds maximum Connectors for RG-316, LMR-100 ........... 20 N/A Mating Torque: 7 to 10 inch-pounds Connectors for LMR-195, 200 .................. 30 N/A Bulkhead Mounting Nut Torque: 15 inch-pounds Connectors for RG-58, LMR-240 ............. 40 N/A Coupling Proof Torque: 15 inch-pounds minimum Connectors for RG-142 ............................ 45 N/A Coupling Nut Retention: 60 pounds minimum Connectors for .086 semi-rigid ................. 30 16 Contact Retention: Connectors for .141 semi-rigid ................. 60 55 6 lbs. minimum axial force (captivated contacts) *Or cable breaking strength whichever is less. 4 inch-ounce minimum torque (uncabled receptacles) Durability: 500 cycles minimum 100 cycles minimum for .141 semi-rigid connectors w/o contact ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph of MIL-C-39012) Temperature Range: - 65C to + 165C Shock: MIL-STD-202, Method 213, Condition I Thermal Shock: MIL-STD-202, Method 107, Condition B Vibration: MIL-STD-202, Method 204, Condition D Corrosion: MIL-STD-202, Method 101, Condition B Moisture Resistance: MIL-STD-202, Method 106 Avoid user injury due to misapplication. See safety advisory definitions inside front cover. CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om