SMA Non-Magnetic RF Connectors INCHES (MILLIMETERS) For Flexible Cable CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Right Angle Crimp Type Plug - Captivated Contact VSWR & FREQ. RANGE GOLD PLATED CABLE TYPE RG-316/u, 188, 174 1.15 + .03f (GHz) 0-12.4 GHz 142-9403-101 SMA Crimp Type Right Angle Plugs CABLE GROUP PART NUMBER CRIMP HEX RG-316/u, 188, 174 142-9403-101 .128 (3.25) For Flexible Cable RG-316 DS, 188 DS 142-9404-101 .151 (3.83) RG-58/u, 141 142-9407-101 .213 (5.41) 1. Identify connector parts. (3 piece parts) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. When stripping LMR-100 low loss cable, remove foil back to where cable jacket is stripped. A wire stripper of correct size is recommended for this step. Twist stranded center conductor into tight bundle and tin (optional). Slide crimp sleeve onto cable as shown. 3. Flare braid and slide cable into body making certain that the cable insulation bottoms on center contact. Solder center conductor to contact through the rear access port. Use a minimum amount of solder for a full fillet joint020 (0.51) diameter solder is recom- mended. 4. Arrange braid uniformly around crimp stem. Slide crimp sleeve over braid and crimp securely using recommended crimp tool. Place expansion cap in access port and seat with .187 (4.75) diameter flat punch. Shrink heat shrink tubing over crimp sleeve if appli- cable. 1 CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST SPECIFICATIONS ELECTRICAL RATINGS Impedance: 50 ohms RF Leakage: (dB minimum, tested at 2.5 GHz) Frequency Range: Flexible cable connectors .......................... 0-12.4 GHz Flexible cable connectors .......................................................................................... -60 dB Uncabled receptacles ................................ 0-18.0 GHz Uncabled receptacles ..................................................................................................... N/A = VSWR: (f = GHz) Straight Cabled Connectors RA Cabled Connectors RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 and 7 MHz) RG-316 ......................................................... 1.15 + .02f 1.15 + .03f Connectors for RG-316 .................................................................................................. 500 RG-58 ........................................................... 1.15 + .01f 1.15 + .02f Connectors for RG-58, uncabled receptacles ................................................................ 670 Uncabled receptacles ........................................................................................................ N/A Working Voltage: (Vrms maximum) MECHANICAL RATINGS Connectors for Cable Type Sea Level 70K Feet Engagement Design: MIL-STD-348, Series SMA RG-316 .............................................................................................. 250 65 Engagement/Disengagement Force: 2 inch-pounds maximum RG-58, uncabled receptacles ............................................................ 335 85 Mating Torque: 7 to 10 inch-pounds Dielectric Withstanding Voltage: (VRMS minimum at sea level) Coupling Proof Torque: 15 inch-pounds minimum Connectors for RG-316 .................................................................................................. 750 Coupling Nut Retention: 60 pounds minimum Connectors for RG-58, uncabled receptacles .............................................................. 1000 Contact Retention: 6 lbs. minimum axial force (captivated contacts) = Corona Level: (Volts minimum at 70,000 feet) 4 inch-ounce minimum torque (uncabled receptacles) Connectors for RG-316 .................................................................................................. 190 Cable Retention: Axial Force*(lbs) Torque (in-oz) Connectors for RG-58, uncabled receptacles ................................................................ 250 Connectors for RG-316 .............................................. 20 N/A Insertion Loss: (dB maximum) Connectors for RG-58 ................................................ 40 N/A Straight flexible cable connectors ....................................... 0.06 f (GHz), tested at 6 GHz *Or cable breaking strength whichever is less. Right angle flexible cable connectors ................................. 0.15 f (GHz), tested at 6 GHz Durability: 500 cycles minimum Uncabled receptacles ...................................................................................................... N/A Insulation Resistance: 5000 megohms minimum ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph of MIL-C-39012) 0 0 Contact Resistance: (milliohms maximum) After Temperature Range: - 65 C to + 165 C Initial Environmental Thermal Shock: MIL-STD-202, Method 107, Condition B Center contact (straight cabled connectors, uncabled receptacles) ... 3.0 4.0 Corrosion: MIL-STD-202, Method 101, Condition B Center contact (right angle cabled connectors) .................................. 4.0 6.0 Shock: MIL-STD-202, Method 213, Condition I Outer contact (all connectors) ............................................................. 2.0 N/A Vibration: MIL-STD-202, Method 204, Condition D Braid to body ....................................................................................... 0.5 N/A Moisture Resistance: MIL-STD-202, Method 106 CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 2 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om