IMX15 / IMY15 / IMS15 Series 15 Watt DC-DC Converter Features Wide input voltage ranges up to 150 VDC 1 or 2 isolated outputs up to 48 V RoHS lead-free-solder and lead-solder-exempted products are available. 5 year warranty for RoHS lead-free-solder products with temperature index -8 1500 to 3000 VAC I/O voltage withstand test Emissions EN 55011, group 1, level A Immunity to EN 50155 and EN 50121-3-2 High efficiency (typ. 86%) Input undervoltage lockout Shutdown input, adjustable output voltages Flex power: Flexible load distribution on outputs 10.5 40.6 0.42 Outputs no-load, overload, and short-circuit proof 1.6 51 Operating ambient temperature 40 to 85 C 2.0 Thermal protection 2 x 1.6 case with 10.5 mm profile Basic insulation: 20/40IMX15 models double or re inforced insulation: 1 10IMY15 models Safety-approved to the latest edition of IEC/EN 60950-1 and UL/CSA 60950-1 1 1 110IMY15 models Table of Contents Description............................................................................2 Electromagnetic Compatibility (EMC) .................................16 Immunity to Environmental Conditions ...............................18 Model Selection ....................................................................2 Functional Description ..........................................................4 Mechanical Data .................................................................19 Electrical Input Data .............................................................5 Safety and Installation Instructions .....................................20 Electrical Output Data...........................................................8 Description of Options ........................................................21 Auxiliary Functions .............................................................14 Accessories ........................................................................22 belfuse.com/power-solutions BCD20008-G Rev AG, 04-Sep-2018IMX15 / IMY15 /IMS15 Series 15 Watt DC-DC Converter Description The IMX15, IMS15, and IMY15 Series of board mountable 15 Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, railways, industry, or telecommu nication, where variable input voltages or high transient voltages are prevalent. Covering a total input voltage range from 8.4 up to 150 V with different models, the converters are available with single and electrically-isolated double outputs from 3.3 up to 48 V, externally adjustable, with flexible load distribution on double-outp ut models. A shutdown input allows for remote on/off. Features include efficient input and output filtering and consistently high efficiency over the entire input voltage range, high reliability, and excellent dynamic response to load and line changes. The converters have been approved by CSA. 20IMS/20IMX15 and 40IMS/40IMX15 models exhibit a basic in sulation. The 110IMY15 models provide double insulation and are CE marked. They may be connected to a rectified 110 VAC source or a 110 V battery without any further insulation barrier. The circuitry is comprised of integrated planar magnetics. All components are automatically assembled and solidly soldered onto a single PCB without any wire connection. Magnetic feedback ensures maximum reliability and repeatability in the control loop over all operating conditions. Careful con si deration of possible thermal stress ensures the absence of hot spots providing long life in environments, where temperature cycles are frequent. The thermal design allows operation at full load up to an ambient temperature of 71 C in free air without using any potting material. For extremely high vibration environments the case has holes for screw fastening. Model Selection Table 1: Model Selection 6 2 Output 1 Output 2 Output Power Input voltage Efficiency Model Options 1 1 V I V I P V to V o nom o nom o nom o nom o nom i min i max min max VDC mA VDC mA W VDC % % 5 SR 3.3 4.5 - - 14.9 8.4 to 36 80 82 20IMX15-03-8RG-G i, Z, non-G 3 3.3 4.0 - - 13.2 16.8 to 75 78 80 40IMX15-03-8RG non-G 3 SR 3.3 4.5 - - 14.9 16.8 to 75 81 83 40IMX15-03-8RG-G i, Z, non-G 4 SR 3.3 4.5 - - 14.9 50 to 150 77 79 110IMY15-03-8RG-G i, Z, non-G 5 SR 5.1 3.5 - - 17.5 8.4 to 36 83 86 20IMX15-05-8RG-G i, Z, non-G 3 SR 5.1 3.5 - - 17.5 16.8 to 75 85 87 40IMX15-05-8RG-G i, Z, non-G 4 SR 5.1 3.5 - - 17.5 50 to 150 79.5 82 110IMY15-05-8RG-G i, Z, non-G 5 5.1 2.3 - - 11.7 8.4 to 36 82 84 20IMX15-05-8R-G Z, non-G 5.1 2.7 - - 13.8 14 to 36 81.5 84 24IMS15-05-9R --- 3 5.1 2.5 - - 12.8 16.8 to 75 81.5 83 40IMX15-05-8R-G --- 4 5.1 2.5 - - 12.8 50 to 150 78 81 110IMY15-05-8R-G Z, non-G 5 5.1 1.35 3.3 1.35 11.3 8.4 to 36 82 84 20IMX15-0503-8RG i, Z, non-G 5.1 1.6 3.3 1.6 13.5 14 to 36 81 83 24IMS15-0503-9R --- 3 5.1 1.5 3.3 1.5 12.6 16.8 to 75 82 84 40IMX15-0503-8RG i, Z, non-G 5.1 1.6 3.3 1.6 13.5 36 to 75 79 82 48IMS15-0503-9R --- 4 5.1 1.5 3.3 1.5 12.6 50 to 150 79 82 110IMY15-0503-8RG i, Z, non-G 5 5 1.3 5 1.3 13.0 8.4 to 36 82 85 20IMX15-05-05-8G i, Z, non-G 5 1.4 5 1.4 14.0 14 to 36 81 84 24IMS15-05-05-9 --- 3 5 1.4 5 1.4 14.0 16.8 to 75 81 84 40IMX15-05-05-8G i, Z, non-G 4 5 1.4 5 1.4 14.0 50 to 150 80 82 110IMY15-05-05-8G i, Z, non-G 5 12 0.65 12 0.65 15.6 8.4 to 36 83 86 20IMX15-12-12-8G i, Z, non-G 12 0.7 12 0.7 16.8 14 to 36 83 86 24IMS15-12-12-9 --- 3 12 0.7 12 0.7 16.8 16.8 to 75 84 87 40IMX15-12-12-8G i, Z, non-G 4 12 0.7 12 0.7 16.8 50 to 150 82 85 110IMY15-12-12-8G i, Z, non-G 5 15 0.5 15 0.5 15.0 8.4 to 36 85 88 20IMX15-15-15-8G i, Z, non-G 15 0.56 15 0.56 16.8 14 to 36 83 86 24IMS15-15-15-9 --- 3 15 0.56 15 0.56 16.8 16.8 to 75 83 86 40IMX15-15-15-8G i, Z, non-G 4 15 0.56 15 0.56 16.8 50 to 150 82 85 110IMY15-15-15-8G i, Z, non-G 5 24 0.32 24 0.32 15.4 8.4 to 36 83 86 20IMX15-24-24-8G i, Z, non-G 24 0.35 24 0.35 16.8 14 to 36 84 87 24IMS15-24-24-9G non-G 3 24 0.35 24 0.35 16.8 16.8 to 75 84 86 40IMX15-24-24-8G i, Z, non-G 4 24 0.35 24 0.35 16.8 50 to 150 82 85 110IMY15-24-24-8G i, Z, non-G 1 Flexible load distribution on dual and double outputs possible up to 75% of the total output power P on one of the 2 outputs. o nom IMX/IMY15-0503 models have reduced load distribution flexibility 1.8 A max. on one of the 2 outputs. The total output power should not exceed P . o nom 2 See Description of Options. 3 Short-time operation down to V = 14.4 V possible (P reduced to approx. 85% of P ) i o o nom 4 Short-time operation down to V = 43.2 V possible (P reduced to approx. 85% of P ) and up to 154 V i o o nom 5 Initial start-up at 9 V, main output voltage regulation down to 8.4 V 6 Efficiency at T = 25 C, V I . A i nom, o nom SR Models with synchronous rectifier. For the RoHS version of such models, add -G NFND: Not for new designs. Preferred for new designs. Replace 24IMS15 models by 20IMX15 and 48IMS15 by 40IMX15 SR Replace 20IMX15-05, 40IMX15-05, 110IMY15-05 by models with synchronos rectifier for new designs, chose always the RoHS version tech.support psbel.com belfuse.com/power-solutions BCD20008-G Rev AG, 04-Sep-2018 2018 Bel Power Solutions & Protection Page 2 of 13