IMX7, IMS7 Series Data Sheet 7-Watt DC-DC Converters Features RoHS lead-free-solder and lead-solder-exempted products are available. Input voltage ranges up to 150 VDC 1 or 2 isolated outputs up to 48 V 1500 to 2000 VAC voltage withstand test Extremely wide input voltage ranges 10.5 Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6 0.42 25.4 50.8 1.0 High efficiency (typ. 84%) 2.0 Input undervoltage lockout Inhibit input, adjustable output voltages Flex power: flexible load distribution on outputs Outputs no-load, overload, and short-circuit proof High reliability and no derating Operating ambient temperature 40 to +85 C Thermal protection Supplementary insulation Planar technology for best mechanical stability Description 2 1 case with 10.5 mm profile The IMX7/IMS7 Series of board-mountable 7 Watt DC-DC Safety-approved to IEC 60950-1 and UL/CSA 60950-1 converters have been designed according to the latest nd 2 Ed. industry requirements and standards. The converters are 1 particularly suitable for use in mobile or stationary applications in transport, railways, industry, or telecom, where variable 1 70/110IMX7 models input voltages or high transient voltages are prevalent. Covering a total input voltage range from 8.4 V to 150 V with six different models, the converters are available with single The circuitry is comprised of integral planar magnetics. All components are automatically assembled and securely and electrically-isolated double outputs from 3.3 up to 48 V with flexible load distribution on double outputs. A shutdown soldered onto a single PCB without any wire connections. input allows remote on/off. Magnetic feedback ensures maximum reliability and repeatability in the control loop over all operating conditions. Features include efficient input and output filtering with good Careful considerations of possible thermal stresses ensure the transient and surge protection, low output ripple and noise, absence of hot spots, providing long life in environments, where consistently high efficiency over the entire input voltage range, temperature cycles are a reality. The thermal design allows and high reliability as well as excellent dynamic response to operation at full load up to an ambient temperature of 85 C in load and line changes. free air without using any potting material. For extremely high The converters provide supplementary insulation with SELV vibration environments the case has holes for screw mounting. outputs as for instances required in battery-supported Several options, such as open-frame, provide a high level of systems, where the bus voltage may exceed the SELV limit of application-specific engineering and design-in flexibility. 60 V. The models 70IMX7 and 110IMX7 are CE-marked. Table of Contents Page Page Electromagnetic Compatibility (EMC) .................................. 11 Description ............................................................................. 1 Immunity to Environmental Conditions ................................ 12 Model Selection ..................................................................... 2 Mechanical Data .................................................................. 13 Functional Description ...........................................................3 Safety and Installation Instructions ...................................... 13 Electrical Input Data ............................................................... 4 Description of Options ......................................................... 14 Electrical Output Data ............................................................ 7 Auxiliary Functions ................................................................. 9 Copyright 2015, Bel Power Solutions Inc. All rights reserved. MELCHER The Power Partners. BCD20007-G Rev AF, 31-Jul-2015 Page 1 of 14IMX7, IMS7 Series Data Sheet 7-Watt DC-DC Converters Model Selection Table 1: Model Selection 1 Output 1 Output 2 Output power Input voltage Efficiency Model Options V I V I P range o1 nom o1 nom o2 nom o2 nom o nom min typ 1 V A V A W V % % 3.3 1.5 - - 5 8.4 36 74 78 20IMX7-03-8 Z, G 3.3 1.5 - - 5 14 36 75.5 79 24IMS7-03-9 Z, G 2 3.3 1.5 - - 5 16.8 75 74.7 79 40IMX7-03-8 Z, G 3.3 1.5 - - 5 36 75 77 79 48IMS7-03-9 Z, G 3.3 1.5 - - 5 40 121 76 78 70IMX7-03-8 Z, G 2 3.3 1.5 - - 5 60 150 74.5 78 110IMX7-03-8 Z, G 5.1 1.2 - - 6.1 8.4 36 75.5 78 20IMX7-05-8 M, Z, G 5.1 1.2 - - 6.1 14 36 77 80 24IMS7-05-9 Z, G 2 75 79 81 40IMX7-05-8 M, Z, G 5.1 1.2 - - 6.1 16.8 5.1 1.2 - - 6.1 36 75 78 81 48IMS7-05-9 Z, G 5.1 1.2 - - 6.1 40 121 75.5 78 70IMX7-05-8 M, Z, G 3 5.1 1.2 - - 6.1 60 150 76 79 110IMX7-05-8 M, Z, G 5 0.6 5 0.6 6 8.4 36 77 81 20IMX7-05-05-8 M, Z, G 5 0.7 5 0.7 7 14 36 79 82 24IMS7-05-05-9 Z, G 2 5 0.7 5 0.7 7 16.8 75 79.5 82 40IMX7-05-05-8 M, Z, G 5 0.7 5 0.7 7 36 75 81.5 83 48IMS7-05-05-9 Z, G 5 0.7 5 0.7 7 40 121 81 82 70IMX7-05-05-8 M, Z, G 3 5 0.7 5 0.7 7 60 150 78 80 110IMX7-05-05-8 M, Z, G 12 0.25 12 0.25 6 8.4 36 80.5 83 20IMX7-12-12-8 M, Z, G 12 0.3 12 0.3 7.2 14 36 81.5 85 24IMS7-12-12-9 Z, G 2 12 0.3 12 0.3 7.2 16.8 75 82.5 84 40IMX7-12-12-8 M, Z, G 12 0.3 12 0.3 7.2 36 75 82 84 48IMS7-12-12-9 Z, G 12 0.3 12 0.3 7.2 40 121 83 85 70IMX7-12-12-8 M, Z, G 3 12 0.3 12 0.3 7.2 60 150 80 83 110IMX7-12-12-8 M, Z, G 15 0.2 15 0.2 6 8.4 36 81 83 20IMX7-15-15-8 M, Z, G 15 0.24 15 0.24 7.2 14 36 81.5 84 24IMS7-15-15-9 Z, G 2 15 0.24 15 0.24 7.2 16.8 75 81 84 40IMX7-15-15-8 M, Z, G 15 0.24 15 0.24 7.2 36 75 82 84 48IMS7-15-15-9 Z, G 15 0.24 15 0.24 7.2 40 121 81.5 83 70IMX7-15-15-8 M, Z, G 3 15 0.24 15 0.24 7.2 60 150 79 82 110IMX7-15-15-8 M, Z, G 24 0.13 24 0.13 6.2 8.4 36 79 83 20IMX7-24-24-8 M, Z, G 24 0.15 24 0.15 7.2 14 36 82 84 24IMS7-24-24-9 Z, G 2 24 0.15 24 0.15 7.2 16.8 75 82 84 40IMX7-24-24-8 M, Z, G 24 0.15 24 0.15 7.2 36 75 82 84 48IMS7-24-24-9 Z, G 24 0.15 24 0.15 7.2 40 121 80 83 70IMX7-24-24-8 M, Z, G 3 24 0.15 24 0.15 7.2 60 150 81 84 110IMX7-24-24-8 M, Z, G 1 Flexible load distribution on double-outputs possible. If only one output is used, connect both outputs of double-output models in parallel. 2 Operation at low input voltage possible, if P is reduced to approx. 80% of P nom at V = 14.1 V. o o i min 3 Up to 154 V for 2 s NFND: Not for new designs. Preferred for new designs Note: Use 20IMX7 to replace 24IMS7 and 40IMX7 to replace 48IMS7. MELCHER The Power Partners. BCD20007-G Rev AF, 31-Jul-2015 Page 2 of 14