M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Features Extremly wide operating input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47 to 440 Hz RoHS lead-solder exemption compliant Class I equipment Input over- and undervoltage lockout 1, 2, or 3 individually isolated and controlled outputs up to 72 V Outputs: SELV, no load, overload, short-circuit proof, rectangular current limiting characteristic Adjustable output voltages with remote on/off Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6 Emissions according to EN 55011/55022 All PCBs boards coated by protective lacquer Very high reliability Battery charger models available 111 4.37 3U 168 39 Safety-approved to IEC/EN 60950-1 and UL/CSA 60950-1 6.6 1.54 nd 8TE 2 Ed. LED indicators display the status of the converter and allow Description visual monitoring of the system at any time. The M Series of DC-DC and AC-DC converters represents a Full input to output, input to case, output to case, and output to broad and flexible range of power supplies for use in advanced output isolation is provided. industrial electronic systems. Features include high efficiency, reliability, low output voltage noise and excellent dynamic The case design allows operation at nominal load up to 71 C response to load/line changes due to individual regulation of in a free-air ambient temperature. If forced cooling is provided, each output. the ambient temperature may exceed 71 C but the case temperature should remain below 95 C under all conditions. The converter inputs are protected against surges and transients occuring at the source lines. An input over- and A temperature sensor generates an inhibit signal, which undervoltage lockout circuit disables the outputs, if the input disables the outputs, when the case temperature T exceeds C voltage is outside the specified range. An inrush current the limit. The outputs automatically recover, when the limitation prevents circuit breakers and fuses from tripping at temperature drops below the limit. switch-on. Various options are available to adapt the converters to All outputs are open- and short-circuit proof, and are protected individual applications. against overvoltages by means of built-in suppressor diodes. The converters may either be plugged into a 19 rack system The outputs can be inhibited by a logic signal applied to the according to IEC 60927-3 or be mounted onto a chassis or a connector (pin 2). If the inhibit function is not used, pin 2 should plate. be connected to pin 23 to enable the outputs. Table of Contents Page Page Description ............................................................................. 1 Electromagnetic Compatibility (EMC) .................................. 14 Model Selection ..................................................................... 2 Immunity to Environmental Conditions ................................ 16 Functional Description ........................................................... 5 Mechanical Data .................................................................. 17 Electrical Input Data ............................................................... 6 Safety and Installation Instructions ...................................... 18 Electrical Output Data ............................................................ 8 Description of Options ......................................................... 20 Auxiliary Functions ............................................................... 11 Accessories.......................................................................... 26 Copyright 2015, Bel Power Solutions Inc. All rights reserved. MELCHER The Power Partners. BCD20018-G Rev AD, 22-May-2015 Page 1 of 26M Series Data Sheet 50 Watt DC-DC and AC-DC Converters than 1000 different types have been manufactured with Model Selection different input/output configurations and customized Non-standard input/output configurations or special custom specialities. Please consult Power-One for additional adaptions are available on request. Table 1 provides an information overview of the basic input and output configurations. More Table 1a: Standard models AM, BM, FM Output 1 Output 2 Output 3 Operating input voltage range and efficiency Options 1 1 1 V I V I V I V V V V V V o nom o nom o nom o nom nom o nom i min i max min i min i max min i min i max min VDC A VDC A VDC A 8 35 VDC % 14 70 VDC % 20 100 VDC % 5.1 8.0 - - - - AM1001-9R 72 BM1001-9R 74 FM1001-9R 74 -7, P, 12 4.0 - - - - AM1301-9R 79 BM1301-9R 80 FM1301-9R 80 D0 D9, 3 15 3.4 - - - - AM1501-9R 79 BM1501-9R 81 FM1501-9R 81 V0 V3 , 24 2.0 - - - - AM1601-9R 81 BM1601-9R 83 FM1601-9R 82 F, A, K, H, 48 1.0 - - - - AM1901-9R 81 BM1901-9R 83 FM1901-9R 83 G 5.1 4.0 5.0 4.0 - - - - BM2001-9 - - - -7, P, 5.1 4.0 24 1.0 - - - - BM2060-9 - - - D0 D9 12 2.0 12 2.0 - - AM2320-9 77 BM2320-9 79 FM2320-9 80 A, K, H, 15 1.7 15 1.7 - - AM2540-9 78 BM2540-9 80 FM2540-9 79 G 24 1.0 24 1.0 - - - - BM2660-9 - -- 5.1 5.0 12 0.7 12 0.7 AM3020-9 75 BM3020-9 76 FM3020-9 76 -7, P, 5.1 5.0 15 0.6 15 0.6 AM3040-9 75 BM3040-9 76 FM3040-9 76 D0 D9 5.1 5.0 24 0.35 24 0.35 - - BM3060-9 - - - K, H, G Table 1b: Standard models CM, DM, LM Output 1 Output 2 Output 3 Operating input voltage range and efficiency Options 1 1 1 V I V I V I V V V V V V o nom o nom o nom o nom nom o nom i min i max min i min i max min i min i max min VDC A VDC A VDC A 28 140 VDC % 44 220 VDC % 88 372 VDC % 2 85 264 VAC 4 5.1 8.0 - - - - CM1001-9R 74 DM1001-9R 74 LM1001-9R 74 -7, E , P 12 4.0 - - - - CM1301-9R 80 DM1301-9R 81 LM1301-9R 80 D0 D9 3 15 3.4 - - - - CM1501-9R 82 DM1501-9R 82 LM1501-9R 79 V0 V3 24 2.0 - - - - CM1601-9R 82 DM1601-9R 83 LM1601-9R 82 A, K, H, 48 1.0 - - - - CM1901-9R 82 DM1901-9R 83 LM1901-9R 82 G 4 5.1 4.0 5.0 4.0 - - CM2001-9 - DM2001-9 LM2001-9 - -7, E , P 5.1 4.0 24 1.0 - - CM2060-9 - DM2060-9 LM2060-9 - D0 D9 12 2.0 12 2.0 - - CM2320-9 79 DM2320-9 80 LM2320-9 80 A, K, H, 15 1.7 15 1.7 - - CM2540-9 80 DM2540-9 80 LM2540-9 79 G 24 1.0 24 1.0 - - CM2660-9 - DM2660-9 LM2660-9 4 5.1 5.0 12 0.7 12 0.7 CM3020-9 76 DM3020-9 77 LM3020-9 74 -7, E , P 5.1 5.0 15 0.6 15 0.6 CM3040-9 76 DM3040-9 76 LM3040-9 73 D0 D9 5.1 5.0 24 0.35 24 0.35 CM3060-9 76 DM3060-9 76 LM3060-9 - A, K, H, G 1 Min. efficiency at V and I . Typ. values are approx. 2% better. i nom o nom 2 Operating frequency range: 47 440 Hz see Safety and Installation Instructions for >60 Hz 3 Option V0, V2, V3 available only for output 1 = 5.1 V (excludes option R) 4 Option E only available for CM and LM models (not for DM) NFND: Not for new designs. Preferred for new designs MELCHER The Power Partners. BCD20018-G Rev AD, 22-May-2015 Page 2 of 26