Cassette Style DC-DC Converters M Series 50 Watt DC-DC (AC-DC) Converters M Series Wide input voltage from 8...373 V DC 1, 2 or 3 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage Extremely wide input voltage range suitable for battery (and AC) operation Efficient input filter and built-in surge and transient suppression circuitry Outputs individually isolated and controlled Outputs fully protected against overload Safety according to IEC/EN 60950 LGA 111 4.37 3U 168 Summary 39 6.6 1.54 8TE The M series of DC-DC (AC-DC) converters represents a broad and flexible range of power supplies for use in ad- vanced industrial electronic systems. Features include high efficiency, reliability, low output voltage noise and excellent dynamic response to load/line changes due to individual regulation of each output. The converter inputs are protected against surges and tran- sients occuring at the source lines. An input over- and agencies LGA (Germany) and UL (USA). The UL Mark for undervoltage lock-out circuitry disables the outputs if the in- Cana-da has been officially recognized be regulatory au- put voltage is outside the specified range. Certain types in- thorities in provinces across Canada. clude an inrush current limitation preventing circuit break- ers and fuses from being damaged at switch-on. The case design allows operation at nominal load up to 71C in a free air ambient temperature. If forced cooling is All outputs are open- and short-circuit proof and are pro- provided, the ambient temperature may exceed 71C but tected against overvoltages by means of built-in suppressor the case temperature should remain below 95C under all diodes. The outputs can be inhibited by a logic signal ap- conditions. plied to the connector pin 2 (i). If the inhibit function is not used pin 2 should be connected to pin 23 to enable the out- A temperature sensor generates an inhibit signal which puts. T exceeds the disables the outputs if the case temperature C limit. The outputs are automatically re-enabled when the LED indicators display the status of the converter and allow temperature drops below the limit. visual monitoring of the system at any time. Various options are available to adapt the converters to in- Full input to output, input to case, output to case and output dividual applications. to output isolation is provided. The modules are designed and built according to the international safety standard The modules may either be plugged into 19 inch rack sys- IEC/EN 60950 and have been approved by the safety tems according to DIN 41494, or be chassis mounted. Table of Contents Page Page Electromagnetic Compatibility (EMC) ............................ 13 Summary .......................................................................... 1 Immunity to Environmental Conditions........................... 15 Type Survey and Key Data .............................................. 2 Mechanical Data ............................................................ 16 Type Key .......................................................................... 3 Safety and Installation Instructions ................................ 17 Functional Description...................................................... 4 Electrical Input Data ......................................................... 5 Description of Options .................................................... 19 Accessories .................................................................... 25 Electrical Output Data ...................................................... 7 Auxiliary Functions ......................................................... 10 Edition 01/01.2001 1/25Cassette Style DC-DC Converters M Series Type Survey and Key Data Non standard input/output configurations or special custom adaptions are available on request. See also: Commercial In- formation: Inquiry Form for Customized Power Supply. The type survey tables provide an overview of the basic input and output configurations. More than 1000 different types have been manufactured providing different output configurations and customized specialities. Please consult Power- One s field sales engineers for specific requirements. The best technical solution will carefully be considered and a detailed proposal submitted. Table 1a: Class I equipment 1 Output 1 Output 2 Output 3 Input voltage range and efficiency Options U I U I U I U ...U h U ...U h U ...U h o nom o nom o nom o nom o nom o nom i min i max min i min i max min i min i max min V DC A V DC A V DC A 8...35 V DC % 14...70 V DC % 20...100 V DC % 5.1 8.0 - - - - AM 1001-7R 72 BM 1001-7R 74 FM 1001-7R 74 9 12.0 4.0 - - - - AM 1301-7R 79 BM 1301-7R 80 FM 1301-7R 80 P 15.0 3.4 - - - - AM 1501-7R 79 BM 1501-7R 81 FM 1501-7R 81 D0...D9 24.0 2.0 - - - - AM 1601-7R 81 BM 1601-7R 83 FM 1601-7R 82 V0,V2,V3 48.0 1.0 - - - - AM 1901-7R 81 BM 1901-7R 83 FM 1901-7R 83 A 12.0 2.0 12.0 2.0 - - AM 2320-7 77 BM 2320-7 79 FM 2320-7 80 H 15.0 1.7 15.0 1.7 - - AM 2540-7 78 BM 2540-7 80 FM 2540-7 79 F 5.1 5.0 12.0 0.7 12.0 0.7 AM 3020-7 75 BM 3020-7 76 FM 3020-7 76 5.1 5.0 15.0 0.6 15.0 0.6 AM 3040-7 75 BM 3040-7 76 FM 3040-7 76 Table 1b: Class I equipment 1 Output 1 Output 2 Output 3 Input voltage range and efficiency Options U I U I U I U ...U h U ...U h U ...U h o nom o nom o nom o nom o nom o nom i min i max min i min i max min i min i max min V DC A V DC A V DC A 28140 V DC % 44220 V DC % 88...372 V DC % (85...264 V AC) 5.1 8.0 - - - - CM 1001-7R 74 DM 1001-7R 74 LM 1001-7R 73 9 12.0 4.0 - - - - CM 1301-7R 80 DM 1301-7R 81 LM 1301-7R 79 E 15.0 3.4 - - - - CM 1501-7R 82 DM 1501-7R 82 LM 1501-7R 78 P 24.0 2.0 - - - - CM 1601-7R 82 DM 1601-7R 83 LM 1601-7R 81 D0...D9 48.0 1.0 - - - - CM 1901-7R 82 DM 1901-7R 83 LM 1901-7R 81 V0,V2,V3 12.0 2.0 12.0 2.0 - - CM 2320-7 79 DM 2320-7 80 LM 2320-7 77 A 15.0 1.7 15.0 1.7 - - CM 2540-7 80 DM 2540-7 80 LM 2540-7 78 H 5.1 5.0 12.0 0.7 12.0 0.7 CM 3020-7 76 DM 3020-7 77 LM 3020-7 73 F 5.1 5.0 15.0 0.6 15.0 0.6 CM 3040-7 76 DM 3040-7 76 LM 3040-7 71 Table 1c: Class II equipment (double insulation) 1 Output 1 Output 2 Output 3 Input voltage range and efficiency Options U I U I U I U ...U h U ...U h U ...U h o nom o nom o nom o nom o nom o nom i min i max min i min i max min i min i max min V DC A V DC A V DC A 28...140 V DC % 44...220 V DC % 88...372 V DC % (85...264 V AC) 5.1 8.0 - - - - CMZ 1001-7R 74 DMZ 1001-7R 74 LMZ 1001-7R 73 9 12.0 4.0 - - - - CMZ 1301-7R 80 DMZ 1301-7R 81 LMZ 1301-7R 79 E 15.0 3.4 - - - - CMZ 1501-7R 82 DMZ 1501-7R 82 LMZ 1501-7R 78 P 24.0 2.0 - - - - CMZ 1601-7R 82 DMZ 1601-7R 83 LMZ 1601-7R 81 D0D9 48.0 1.0 - - - - CMZ 1901-7R 82 DMZ 1901-7R 83 LMZ 1901-7R 81 V0,V2,V3 A 12.0 2.0 12.0 2.0 - - CMZ 2320-7 79 DMZ 2320-7 80 LMZ 2320-7 77 H 15.0 1.7 15.0 1.7 - - CMZ 2540-7 80 DMZ 2540-7 80 LMZ 2540-7 78 F 5.1 5.0 12.0 0.7 12.0 0.7 CMZ 3020-7 76 DMZ 3020-7 77 LMZ 3020-7 73 5.1 5.0 15.0 0.6 15.0 0.6 CMZ 3040-7 76 DMZ 3040-7 76 LMZ 3040-7 71 1 Efficiency at U and I . i nom o nom Notes: EM types with an input voltage range of 67...385 V DC are available upon request. LM types may be operated in AC mode within a frequency range of 47...440 Hz and LMZ types within a frequency range of 47...65 Hz. See: AC-DC converters 100 W: M-Series. Edition 01/01.2001 2/25