Linear Power Supplies Data Sheet Features RoHS compatible for all six substances Worldwide AC Input Capabilities: 100/120/220/230/240 VAC 0.05% Output Regulation Low Output Ripple UL, CSA, and TV Approvals Mean Time Before Failure (MTBF) in Excess of 300,000 Hours CE marked to Low Voltage Directive 100% Burn-In 2 Year Warranty Overvoltage Protection (OVP) Standard on 5V Single Outputs, Optional for other outputs under 48V Description Power-One produces the industrys broadest selection of DC power. Linear power supplies with output voltages from 5 volts The Linear power supplies are approved to domestic and through 250 volts. Rugged technology and proven design international regulatory standards, and are CE Marked to merge to create quiet, highly-regulated, dependable the Low Voltage Directive (LVD). Overvoltage Protection Options OVERVOLTAGE PROTECTION OPTIONS OVP SELECTION GUIDE These optional overvoltage protection modules are offered for use with MODEL CASE SIZE OVP MODULES REQUIRED Power-Ones Linear power supplies. Each is user adjustable from 6.4V to 34V. B,C,N,D (1) OVP-12G SINGLE OUTPUT E,F (1) OVP-24G OVP-12G AA,B,BB,CC (1) OVP-12G protects both outputs DUAL OUTPUT E (1) OVP-24G protects both outputs AA,BAA,D (1) OVP-12G protects both 12V TRIPLE CBB, 131 OUTPUT through 15V outputs DBB,DCC N,BAA,CBB PEAK (1) OVP-12G protects any output CURRENT 131 not provided with built-in OVP MODELS NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48V through 250V models. OVP-24G MCD10016 Rev. 1.2, 13-Nov-09 Page 1 of 9 www.power-one.comLinear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Max Model Input Case Additional Case Dimensions Type (Inches) Vout* Amps 100 to 264 VAC Type Features & Notes AA 6.50 x 4.00 x 2.10 5Vout B 4.87 x 4.00 x 2.10 5 1.5 HA5-1.5/OVP-AG B A BAA 10.25 x 4.00 x 2.95 5 3 HB5-3/OVP-AG B A, C BB 7.00 x 4.87 x 2.95 5 6 HC5-6/OVP-AG C A, C C 5.62 x 4.87 x 2.95 5 9 HN5-9/OVP-AG N A, C CBB 11.00 x 4.87 x 3.28 5 12 HD5-12/OVP-AG D A, C CC 9.38 x 4.87 x 3.28 5 18 HE5-18/OVP-AG E A, C CP131 11.00 x 4.87 x 3.28 5 25 F5-25/OVP-AG F A, C, D, H D 9.00 x 4.87 x 3.28 5 35 G5-35/OVP-AG F A, C, D, H DBB 14.25 x 4.87 x 3.38 5 50 CP197-AG F A, C, D DCC 15.00 x 4.88 x 4.55 12 to 15Vout E 14.00 x 4.87 x 3.53 12 0.9 HA15-0.9-AG B F 16.75 x 4.88 x 5.00 12 1.7 HB12-1.7-AG B C N 7.00 x 4.87 x 3.28 12 3.4 HC12-3.4-AG C C 12 5.1 HN12-5.1-AG N C 12 6.8 HD12-6.8-AG D C Case Dimensions 12 10.2 HE12-10.2-AG E C Type (Millimeters) 12 16 F15-15-AG F C, D, H AA 165.10 x 101.60 x 53.34 15* 0.9 HA15-0.9-AG B B 123.70 x 101.60 x 53.34 15 1.5 HB15-1.5-AG B C BAA 260.35 x 101.60 x 74.93 15 3 HC15-3-AG C C BB 177.80 x 123.70 x 74.93 15 4.5 HN15-4.5-AG N C C 142.75 x 123.70 x 74.93 15 6 HD15-6-AG D C CBB 279.40 x 123.70 x 83.31 15 9 HE15-9-AG E C CC 238.25 x 123.70 x 83.31 15* 15 F15-15-AG F C, D, H CP131 279.40 x 123.70 x 83.31 24 to 28Vout D 228.60 x 123.70 x 83.31 24 0.5 HA24-0.5-AG B DBB 361.95 x 123.70 x 85.85 24 1.2 HB24-1.2-AG B C DCC 381.00 x 123.95 x 115.57 24 2.4 HC24-2.4-AG C C E 355.60 x 123.70 x 89.66 24 3.6 HN24-3.6-AG N C F 425.50 x 123.95 x 127.00 24 4.8 HD24-4.8-AG D C N 177.80 x 123.70 x 83.31 24 7.2 HE24-7.2-AG E C 24 12 F24-12-AG F C, D, H (See Additional Features Column) 28* 0.5 HA24-0.5-AG B A Overvoltage protection, set at 6.2 V 0.4 V. 28 1 HB28-1-AG B C B Non-adjustable 3-terminal regulator. 28 2 HC28-2-AG C C C Remote sense provided. 28 3 HN28-3-AG N C D With output inhibit and parallel operation master/slave capability. 28 4 HD28-4-AG D C E With output inhibit. 28 6 HE28-6-AG E C F Adjustable 3-terminal regulator. 28* 10 F24-12-AG F C, D, H G Can be made into an isolated output by removing jumper W1. 48Vout H Model requires 100 LFM forced-air 48 0.5 HB48-0.5-AG B cooling above 75% of rated output power at 50 degrees C. 48 1 HC48-1-AG C 48 3 HD48-3-AG D C 48 4 HE48-4-AG E C * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10016 Rev. 1.2, 13-Nov-09 Page 2 of 9 www.power-one.com