LDP200-200 is the first user programmable unit on the market that can supply any voltage between 36 and 205 VDC, offering unmatched flexibility for many applications. Its compact size, high efficiency, excellent reliability together with easy installation makes it ideal for various industrial applications. LDP200-200 is Class I isolation device suitable for SELV and PELV circuitry and is designed to be mounted on DIN rail and installed inside a protective enclosure. High efficiency and compact size Active PFC Wide input voltage range 170 - 550 VAC Wide output voltage range 36 - 205 VDC, user settable 2 user programmable voltage steps with settable duration Digital control Remote ON/OFF or other remote control functions possible through ENABLE input Multiple protections Ideal for elevator application Excellent versatility, allowing parts stock savings Up to 50C operating temperature with no derating Industrial Control Communication Instrumentation Equipment Renewable Energy Systems 2 LDP200-200 LDP200-200 230 / 400 V (range 170 - 550 VAC) 36-205 VDC 2.3 A max * * 2.3 A max. for Vout < 80 V. For Vout > 80 V output is limited by output power 187 W max. Technical parameters are typical, measured in laboratory environment at 25C and 400 VAC / 50 Hz, at nominal values, after minimum 5 minutes of operation. Single or two phases 200 - 500 VAC 1 Input AC Voltage Range Operating 170 - 550 VAC Input DC Voltage Range 250 725 VDC Input Frequency 47 - 63 Hz Vin = 200 VAC 1.4 A Input AC Current Vin = 500 VAC 0.5 A Vin = 250 VDC 1.4 A Input DC Current Vin = 725 VDC 0.7 A Power Factor Correction Active > 0.9 Standby Power < 6 W Inrush Peak Current 50 A Touch (Leakage) Current 0.3 mA Internal Protection Fuse None, external fuse must be provided It is strongly recommended to provide external MCB 6 A, C curve or 4A D curve Recommended External Protection surge arresters (SPD) according to local regulations. 1 CB Scheme certified up to 528 VAC. Output Power 200 W Rated Voltage 1 V resolution programmable 36 205 VDC Continuous Current or Vout x Iout = max. 187 W for Vout > 80 V Max 2.3 A Overload Limit 2.4 A Short Circuit Peak Current 2.5 A Load Regulation 1% 2 Ripple & Noise 600 mVpp Hold up Time 30 ms Overload and short circuit with constant current (3 s) and one shot (no auto recovery) Thermal protection Protections Input undervoltage lockout (UVLO) Input overvoltage protection (VDR) 7 segment, 3 digits display Status Signals 3 programming keys ENABLE - Insulated remote ON/OFF input, active for 12 - 230 VAC/DC Parallel Connection Possible with external ORing module Efficiency > 87% Dissipated Power < 28 W 2 Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1 F MKP parallel capacitor. tech.support psbel.com