The RNS / RND Series of converters are industry standard, 2 1 size, low profile, single- and double-output DC-DC converters intended for SMT placement and reflow soldering. The product provides onboard conversion of a wide range of standard telecom, datacom and industrial input voltages to isolated low output voltages without the need for any additional cooling. Proprietary patented manufacturing process ensures optimal quality through full process automation. The converters are cost effective high performance alternatives to competing products on the market. RoHS lead-free and lead-solder-exempt products are available Single- and double-output models Basic isolation 1500 VDC I/O electric strength test voltage Synchronization function Low profile 8.5 mm height Excellent co-planarity Convection cooling Low conducted and radiated EMI Wide input range Output overcurrent protection Remote on/off (primary referenced) Output voltage trim adjust, positive or negative Operating temperature up to 110C Approved to the latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1 Distributed power architectures Telecommunications equipment LAN/WAN applications Industrial applications Data processing 2 RNS / RND Series INPUT MAX INPUT OUTPUT OUTPUT RATED OUTPUT TYPICAL 1 MODEL VOLTAGE CURRENT VOLTAGE CURRENT RIPPLE/NOISE EFFICIENCY VDC A V A mV % PP RNS01EE-M6 18 72 0.5 3.30 1.5 25 78 2 RNS03ZE-M6 38 75 0.4 2.50 / 3.30 3.0 50 79 RNS01EG-M6 18 72 0.5 5.05 1.2 25 79 RNS02ZG-M6 38 75 0.4 5.05 2.0 50 83 RNS0.9ET-M6 18 72 0.5 7.00 0.9 25 80 2 RNS0.6ZH-M6 38 75 0.3 12.0 / 15.0 0.6 40 83 INPUT MAX. INPUT OUTPUT OUTPUT RATED OUTPUT TYPICAL VOLTAGE CURRENT VOLTAGE CURRENT RIPPLE/NOISE EFFICIENCY 1 MODEL VDC A V A mVPP % +3.27 1.0 RND02ZGE-M6 38 75 0.4 50 81 +5.20 1.0 RND02ZGG-M6 38 75 0.4 5.10 1.0 50 81 2 RND0.8ZHH-M6 36 75 0.4 12.0 / 15.0 0.42 50 85 Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability and cause permanent damage to the converter. All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN MAX UNIT Continuous RNS01EE/RNS01EG/RNS0.9ET (18) (72) VDC Input voltage (Vin) All other models 38 75 VDC Transient input voltage (Vint) Transient, 100 ms 100 VDC Operating CaseTemp. (Tc) All operating conditions -45 110 C Storage Temperature (Ts) -55 125 C ON/OFF Control Voltage (Vrc) Referenced to -Vin -5 16 V PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNIT Shock IEC68-2-27 100 g Sinusoidal Vibration IEC68-2-6 10 g Weight 0.6/17 oz/g Water Washing Standard process Yes MTBF Per Bellcore TR-NWT-000332 (100% load at 25 C,GB) 4590 1000 h 1 Add G to the end of the part number for products, which comply to RoHS for all 6 substances. 2 Output voltage adjusted using the trim function. tech.support psbel.com