NON-ISOLATED DC/DC CONVERTERS 4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /12 A Outputs Jul. 29, 2015 Bel Power, Inc. , a subsidiary of Bel Fuse, Inc. SLIN-12E1Ax RoHS Compliant Rev.I Features Wide Input Voltage Range Ability to Sink and Source Current Fixed Switching Frequency Cost Efficient Open Frame Design Power Good Signal Over Temperature Protection Remote Sense Output Over Current Protection Remote On/Off TM Tunable Loop (a registered trademark of Lineage Power Systems) to Optimize Dynamic output voltage response Flexible output voltage sequencing Fixed switching frequency and ability to synchronize with external clock Class 2, Category 2, Non-Isolated DC/DC Converter (refer to IPC-9592A) Compliant to RoHS EU Directive 2002/95/EC Compatible in a Pb-free or SnPb reflow environment Certificated to UL60950-1/CSA C22.2 No.60950-1, 2rd VDE 0805:2001-12 (EN60950-1) Licensed Applications Distributed power architectures Servers and storage applications Intermediate bus voltage applications Networking equipment Telecommunications equipment Industrial equipment Description The SLIN-12E1Ax power modules are non-isolated dc-dc converters that can deliver up to 12A of output current. These modules operate over a wide range of input voltage (V = 4.5Vdc-14Vdc) and provide a precisely IN regulated output voltage from 0.69Vdc to 5.5Vdc, programmable via an external resistor. Two new features added with this family of products are the ability to externally tune the voltage control loop and frequency synchronization. Other features include remote On/Off, adjustable output voltage, over current and over TM temperature protection, power good and output voltage sequencing. The Tunable Loop , allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. Part Selection Max. Output Typical Model Number Model Number Output Voltage Input Voltage Current Efficiency Active High Active Low 0.69 Vdc - 5.5 Vdc 4.5 Vdc - 14 Vdc 12 A 94.3% SLIN-12E1A0 SLIN-12E1AL Notes: 1. Add R suffix at the end of the model number to indicate tape and reel packaging (Standard). 2. Add G suffix at the end of the model number to indicate tray packaging (Option). Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com 1 NON-ISOLATED DC/DC CONVERTERS 4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /12 A Outputs Jul. 29, 2015 Bel Power, Inc. , a subsidiary of Bel Fuse, Inc. Part Number Explanation S LIN 12 E 1A 0 1 2 3 4 5 6 1---Surface mount 5---With sequencing 2---Series code 6---Enable, active high, change 0 to L means active low 3---Output current (12A) 7---Package 4---Wide input voltage range (4.5-14V) Absolute Maximum Ratings Unit Parameter Min Typ Max Notes Continuous Input Voltage -0.3 - 15 V Voltage on SEQ terminal -0.3 - Vin V Voltage on SYNC terminal -0.3 - 12 v Voltage on PG terminal -0.3 - 6 V Operating Ambient Temperature -40 - 85 C Storage Temperature -55 - 125 C Altitude - - 2000 m Note: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Input Specifications Parameter Min Typ Max Unit Notes Operating Input Voltage 4.5 - 14 V Input Current (full load) - - 11.5 A V =4.5V to 14V IN - 26 - mA Vo=0.69V, V =10V, I =0, module enabled IN O Input Current (no load) - 60 - mA Vo=3.3V, V =12V, I =0, module enabled IN O Input Stand-by Current - 1.2 - mA V = 12V, module disabled IN Input Reflected Ripple Current 5Hz to 20MHz, 1H source impedance V IN - 70 - mA (pk-pk) =0 to 14V I = I , O Omax 2 2 I t Inrush Current Transient - - 1 A s Input Ripple Rejection (120Hz) - 45 - dB Turn-on Threshold - 4.45 - V Turn-off Threshold - 4.2 - V Hysteresis - 0.25 - V CAUTION: This converter is not internally fused. An input line fuse must be used in application. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15A. Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com 2