BIAS 2 Watt Power Supply BPWX 2 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPWX 2-08-00, -08-33, -08-50 BPWX 2-14-00, -14-33, -14-50 Actual Size The BPWX Power Supply Module is an ideal solution for numerous Features control applications in lighting, sensing, smart building and power Universal Input (90-308 VAC, 50/60Hz) o distribution where operation from 277VAC mains and an extended Extended temperature range (-40 to 85 C) 3 3 temperature range are required. This low-cost supply provides up to Small Size0.87in 14.3cm two watts of output power at 8 or 14 VDC (Vo) and an optional 3.3 or Low no-load input power <30mW 5 VDC (Vr) output for logic functions such as a microprocessor, logic, Constant power mode, not current limit timing circuits, transceivers or sensors. A patented design incorporat- 3000 VAC Isolation 3 ing a custom integrated circuit into a small package (0.87 in 14.3 Up to 75% efficiency 3 cm ) the BIAS Module provides an immediate drop-in solution, EN 55022, Class B FCC Part 15, Class B requiring no additional external components. Meets UL/CSA and EN Product Safety (ITE) Operating Specifications Bias Power AC/DC power supplies are designed to be o ( 120VAC / 60 Hz / 25 C unless otherwise specified) applied in two major categories of applications Auxiliary, where the Bias supply is one of two or more sup- Electrical plies and provides power for standby, housekeeping, bias- Input Voltage Range 90-308 VAC (50/60Hz) ing or other requirements. Generally, these supply 3.3V or Input Surge Withstand 345V, < 30 sec 5.0V requirements from the Vr output. In some cases a small amount of Vo power is used. 2.0 W min. (60Hz) Output Power (Pmax) 1.67 W min. (50Hz) Second is as a main or utility supply where Bias is the only Efficiency 70% nom. supply and provides all power necessary for the product or system. Both Vr and Vo supplies are often utilized for opti- Output Vo (Peak) 8 or 14 VDC nom. +/- 5% mum system performance. Line / Load Regulation Vo (Peak) +/- 1% Po < Pmax The characteristics of the Vo and Vr outputs are different Temperature Regulation Vo (Peak) +/- 2% Po < Pmax and each has application-specific benefits which can pro- vide high value to the system designer. Ripple Vo ( 120 Hz) 1.00 V p:p ( 100 kHz) 0.25 V p:p Vo is a voltage-regulated output which has a constant For Vo = 8V, Ir out 160mA max, Io+Ir 250mA* power mode instead of a conventional current limit. This Output Vr, 3.3 volt (+/- 5%) For Vo = 14V, Ir out 70mA max, Io+Ir 143mA* output is best suited to drive mechanical relays, solenoids, For Vo = 8V, Ir out 250mA max, Io+Ir 250mA* SSRs, capacitive loads, indicating lights, LEDs and as a Output Vr, 5.0 volt (+/- 5%) For Vo = 14V, Ir out 83mA max, Io+Ir 143mA* source for isolated DC utility power which may be used directly or post-regulated with either a linear regulator or a No-load Consumption 30 mW typical Vin=120 VAC DC/DC converter. Vo is self protecting, cannot be over- 3000 VAC (meets UL / CSA & loaded and can be shorted indefinitely. The graceful transi- Isolation EN Product Safety) tion from voltage regulation to constant power along with Earth Leakage 120 VAC < 10 uA the wide range of product ratings, allows the designer to select a supply tightly matched to the design load. There is Short Circuit Protection Continuous, Pin 0.6 w Vin = 120 VAC no need to oversize a Bias Power supply. Unlike design- Reliability 25 C, MIL HDBK-217F > 500 Khr MTBF your-own, or partially complete modules where significant design margin is required, to stay far away from current Thermal limit, Biass constant power alternative requires no such o Operating Temperature -40 to +85 C over-specing. Operating Relative Humidity 0 95%, non-condensing Vr is also a voltage-regulated output and is thermally pro- o Storage Temperature -40 to +105 C tected from overload. It has very low output ripple capable of driving microprocessors , logic, transceivers, sensors and Mechanical other elements which require a low-noise, tightly-regulated Package Size 1.35 x 1.12 x 0.58 inches supply. In addition, Vr is supplied internally by Vo. This (L x W x H) 34.214 x 28.372 x 14.757 mm means that any capacitance added to Vo can increase the Safety hold-up time of Vr as well. nd Safety Compliance UL/EN 60950-1, 2 Ed. (CB Report Available) *Note: maximum currents specified for constant voltage EMI Emissions EN 55022, Class B, FCC Part 15, Class B range only. See V-I curve on page 2 for Vo in constant power range. BPWX 2 Series Data Sheet, Page 1 of 5 BIAS Power Revised 02/08/2011 www.biaspower.com Specifications subject to change BIAS 2 Watt Power Supply BPWX 2 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPWX 2-08-00, -08-33, -08-50 BPWX 2-14-00, -14-33, -14-50 No Load Pow er VS Input Voltage V-I, typical 10 150 9 Constant Power Region 130 8 110 7 6 90 5 70 4 50 3 30 2 1 10 0 85 110 135 160 185 210 235 260 0 100 200 300 400 500 600 700 800 Input Voltage (Vac) Io, mA EMI, conducted, dBV, typical EMI, radiated signal strength, dBV/m, typical P eak Repetitive P ulse Loading Output Regulation, Vo 16 2000 14 1750 1500 12 100% Load 1250 8V M ax 10 50% Load Ipk 1000 25% Load 14V 8 750 max Ipk 500 6 250 4 0 0.000 2.083 4.165 6.248 8.330 0 8.3 16.6 24.9 33.2 41 .5 49.8 Time(m S) Time, mSec BPWX 2 Series Data Sheet, Page 2 of 5 BIAS Power Revised 02/08/2011 www.biaspower.com Specifications subject to change Output Current(mA) Input Power (mW) Vo, volts