FCC and IC RFI Statements Trademarks Chapter 3: Operation NOM Statement LGH008A FEDERAL COMMUNICATIONS COMMISSION AND Normas Oficiales Mexicanas (NOM) 3.3 Network Connector Pin Assignments Electrical Safety Statement INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS Table 3-2. RJ-45 connector pinout. INSTRUCCIONES DE SEGURIDAD This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used 8-Port Hardened Edge Switch properly, that is, in strict accordance with the manufacturers instructions, may cause inter ference to radio MDI MDI RJ-45 1. Todas las instrucciones de seguridad y operacin debern ser ledas antes de que el aparato elctrico sea operado. communication. It has been tested and found to comply with the limits for a Class A computing device in connector Pin (1000BASE-T) (10/100BASE-T) 2. Las instrucciones de seguridad y operacin debern ser guardadas para referencia futura. accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable Link eight 10-/100-/1000-Mbps devices to this 3. Todas las advertencias en el aparato elctrico y en sus instrucciones de operacin deben protection against such interference when the equipment is operated in a commercial environment. Operation of 1 TP1+ TX+ BLACK BOX tough, industrial-grade switchs RJ-45 ports. ser respetadas. this equipment in a residential area is likely to cause interference, in which case the user at his own expense will 2 TP1- TX- 4. Todas las instrucciones de operacin y uso deben ser seguidas. be required to take whatever measures may be necessary to correct the interference. 5. El aparato elctrico no deber ser usado cerca del agua por ejemplo, cerca de la tina de bao, lavabo, stano Includes two power LEDs and a 5-pin terminal block power Changes or modifications not expressly approved by the party responsible for compliance could void the 3 TP2+ RX+ connector. mojado o cerca de una alberca, etc. users authority to operate the equipment. Figure 3-1. RJ-45 connector. 6. El aparato elctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante. This digital apparatus does not exceed the Class A limits for radio noise emiss ion from digital apparatus set 4 TP3+ 7. El aparato elctrico debe ser montado a la pared o al techo slo como sea recomendado out in the Radio Interference Regulation of Industry Canada. por el fabricante. 5 TP3- Le prsent appareil numrique nmet pas de bruits radiolectriques dpassant les limites applicables aux 8. Servicio El usuario no debe intentar dar servicio al equipo elctrico ms all lo descrito appareils numriques de la classe A prescrites dans le Rglement sur le brouillage radiolectrique publi par en las instrucciones de operacin. Todo otro servicio deber ser referido a personal de 6 TP2- RX- Industrie Canada. servicio calificado. 9. El aparato elctrico debe ser situado de tal manera que su posicin no interfiera 7 TP4+ su uso. La colocacin del aparato elctrico sobre una cama, sof, alfombra o superficie similar puede bloquea la Warranty and Return Information ventilacin, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilacin. 8 TP4- 10. El equipo elctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, If you determine that your LGH008A is malfunctioning, do not attempt to alter or estufas u otros aparatos (incluyendo amplificadores) que producen calor. repair the unit. It contains no user-serviceable parts. Contact Black Box Technical RJ-45 8-pin straight-through wiring RJ-45 8-pin crossover wiring 11. El aparato elctrico deber ser connectado a una fuente de poder slo del tipo descrito en Support at 724-746-5500 or info blackbox.com. el instructivo de operacin, o como se indique en el aparato. Switch PC (NIC) Switch Switch 12. Precaucin debe ser tomada de tal manera que la tierra fisica y la polarizacin del equipo Before you do, make a record of the history of the problem. We will be able to 3 ---------------------------- 3 3 ----------------------------1 no sea eliminada. provide more efficient and accurate assistance if you have a complete description, 6 ---------------------------- 6 6 ----------------------------2 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos including the nature and duration of the problem, when the problem occurs, and 1 ---------------------------- 1 1 ----------------------------3 colocados sobre o contra ellos, poniendo particular atencin a los contactos y receptculos donde salen del aparato. any particular application that, when used, appears to create the problem or make 14. El equipo elctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante. 2 ---------------------------- 2 2 ----------------------------6 it worse. 15. En caso de existir, una antena externa deber ser localizada lejos de las lineas de energia. 4 ---------------------------- 4 4 ----------------------------7 16. El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. Copyright 2011. Black Box Corporation. All rights reserved. Black Box and the Double Diamond 5 ---------------------------- 5 5 ----------------------------8 logo are registered trademarks of BB Technologies, Inc. UL is a registered trademark of 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre 7 ---------------------------- 7 7 ----------------------------4 Underwriters Laboratories. Any third-party trademarks appearing in this manual are acknowledged la cubierta u orificios de ventilacin. 8 ---------------------------- 8 8 ----------------------------5 to be the property of their respective owners. 18. Servicio por personal calificado deber ser provisto cuando: A: El cable de poder o el contacto ha sido daado u Figure 3-2. RJ-45 straight-through and LGH008A, version 1 B: Objectos han cado o lquido ha sido derramado dentro del aparato o crossover wiring diagrams. C: El aparato ha sido expuesto a la lluvia o Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. Customer D: El aparato parece no operar normalmente o muestra un cambio en su desempeo o Support call 724-746-5500) FREE technical support 24 hours a day, 7 days a FREE Live, 24/7 Tech Support is just 30 seconds away. E: El aparato ha sido tirado o su cubierta ha sido daada. week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Information 724-746-5500 blackbox.com Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info blackbox.com LGH008A 724-746-5500 blackbox.com LGH008A 724-746-5500 blackbox.com Chapter 1: Overview Chapter 1: Overview Chapter 2: Hardware Installation Chapter 2: Hardware Installation Chapter 3: Operation Step 2: Connecting the Power 1. Overview Table 1-1. LGH008A components. 3. Operation P repare a suitable 9-48 VDC power source and connect it to the switch via a 1.1 Introduction 3.1 LED Indicators Number Component Description 5-pin terminal block. The 8-Port Hardened Edge Switch has eight 10/100/1000BASE-TX RJ-45 LED indicators are located on the front panel of the switch. Ethernet ports and two Power LEDs. It uses a 5-pin terminal block power You can connect two DC inputs into the switch power if auto-backup is needed. 1 (8) RJ-45 ports Link to 10-/100-/1000-Mbps Ethernet devices connector. Table 3-1. LED indicators. Check P1/P2 power LED. The LED(s) will light when the device is ready. 2 (2) Power LEDs Light when power to the switch is on NOTE: The switch should be mounted on a well-grounded place, such as a Name LED Status Description 3 5-pin terminal block Power connector Table 2-1. 5-pin terminal block pinning. P2 P1 metal panel. V- V+ V+ V- FG Off Power input 1/2 is not plugged in yet 1.2 Whats Included P1/P2 Green Pin V+ V- F.G. 2. Hardware Installation Your package should include the following items. If anything is missing or dam- On Power status is ready aged, contact Black Box Technical Support at 724-746-5500 or info blackbox. Step 1: Installation on DIN Rail Signal 948 VDC 0 V Frame Ground Figure 2-2. 5-pin terminal com. Off Link is broken or no cable is plugged in The Hardened Edge Switch has a DIN rail bracket attached to the rear panel. Follow block connector. the steps below to fasten the switch to the DIN rail correctly. Green (1) 8-Port Hardened Edge Switch (1) 5-pin terminal block for power input Tip the switch forward and press it against the DIN rail after aligning the bracket Blinking The device is transferring data through the port WARNING: Before connecting the switch to the DC power input, make sure the DC RJ-45 This users manual springs to the DIN rail. voltage supplied by the power source is correct and stable. Press the bracket against the upper ledge of the DIN rail until it clicks. Off The link is operating at a rate of 10/100 Mbps Step 3: Connecting the Network Devices Optional accessories: Yellow Connect your devices using standard UTP/STP cable with RJ-45 connectors to the On The link is operating at a rate of 1000 Mbps Wallmount kit (45.4 2.3 cm thick switch. (For the cable wiring diagrams, refer to the pin assignment in Figure 3-2.) T he corresponding RJ-45 LED will light if the Ethernet connection is linked 1.3 Hardware Description 3.2 Configuration and Setting Methods successfully. Figure 1-1 shows the Hardened Edge Switchs front panel. Table 1-1 describes No configuration and setting methods are needed. The LED will blink while the switch transfers data. its components. UL Notice for Power Supply 3 2 Use a power supply marked with LPS, Limited Power Source, or Class 2 with output rate 9-48 VDC, 0.45 A maximum. DIN rail 1 1 Figure 2-1. Installing the LGH008A on a DIN rail. Figure 1-1. Front panel. Page 1 Page 2 Page 3 Page 4 LGH008A 724-746-5500 blackbox.com LGH008A 724-746-5500 blackbox.com LGH008A 724-746-5500 blackbox.com LGH008A 724-746-5500 blackbox.com X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Tactile Switches category: Click to view products by Black Box manufacturer: Other Similar products are found below : KMR633NG LFG 5GTH92001 5GTH9202242 6426-201-11343 MJ1226 MJTP1109B MJTP1138EAUTR MJTP1230BL MJTPSHW GS6.90F300QP 1-1977223-0 1-1977120-4 ADTSA62NV ADTSA62RV ADTSA63KV ADTSA644NV ADTSM24NVTR ADTSMW66NV ADTSMW67RV ATM533VTR 1571300-3 B3F-3123 B3F-6055A B3F-B32-01-KIT 1977177-8 1977266-1 2-1977223-4 2-1977223-7 ADTS644KV ADTSA61RV ADTSA62KV ADTSA63NV ADTSA63RV ADTSA65NV ADTSM21NSVTR ADTSM25RVTR ADTSM31RVTR ADTSM32NVTR ADTSM61YVTR ADTSM63SVTR ADTSM644KVTR ADTSMW64RV ADTSMW69NV FSMRA4JHA04 GS4.70F300QP D38999/20JJ37SA TL1105B TL1105J ATH447K2Q ATM534VTR