PCB Transf Or mers Short circuit proof PCB transformer Short circuit proof PCB transformer AVB AVB Type AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/.. General Data Input Rated input Voltage 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac Rated input voltage 2 x 115 Vac Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz Rated output voltage 6 - 2 x 24 Vac Output Rated power 0.35 - 3.2 VA Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6 2x6 Vac: AVB 0,5/2/6 2x6 Vac: AVB 1,0/2/6 2x6 Vac: AVB 1,5/2/6 2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6 Insulation class B 2x2 Vac: AVB 0,35/2/9 2x8 Vac: AVB 0,5/2/8 2x9 Vac: AVB 1,0/2/9 2x8 Vac: AVB 1,5/2/8 2x8 Vac: AVB 2,3/2/8 2x12 Vac: AVB 0,35/2/12 2x9 Vac: AVB 0,5/2/9 2x12 Vac: AVB 1,0/2/12 2x9 Vac: AVB 1,5/2/9 2x9 Vac: AVB 2,3/2/9 Maximum ambient temperature 70 C 2x15 Vac: AVB 0,35/2/15* 2x12 Vac: AVB 0,5/2/12 2x15 Vac: AVB 1,0/2/15 2x12 Vac: AVB 1,5/2/12 2x12 Vac: AVB 2,3/2/12 2x18 Vac: AVB 0,35/2/18* 2x15 Vac: AVB 0,5/2/15* 2x18 Vac: AVB 1,0/2/18* 2x15 Vac: AVB 1,5/2/15 2x15 Vac: AVB 2,3/2/15 2x24 Vac: AVB 0,35/2/24* 2x18 Vac: AVB 0,5/2/18* 2x24 Vac: AVB 1,0/2/24* 2x18 Vac: AVB 1,5/2/18* 2x18 Vac: AVB 2,3/2/18* Efficiency up to 59 % 2x24 Vac: AVB 0,5/2/24* 2x24 Vac: AVB 1,5/2/24* 2x24 Vac: AVB 2,3/2/24* Degree of protection IP 00 Rated Power 0.35 VA 0.50 VA 1.00 VA 1.50 VA 2.00 VA 2.30 VA No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43 No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W Advantages Efficiency 30 % 40 % 55 % 57 % 0 % 59 % Minimum size at high output Standards Unconditionally short-circuit proof Classification Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Double input voltage for series or parallel connection *Mains transformer *Mains transformer *Mains transformer *Mains transformer *Mains transformer Also with double output voltage for series or parallel connection Approvals Designed for high ambient temperatures Approvals cURus cURus cURus cURus cURus cURus Permanent corrosion protection, high insulation value and maximum Environment electrical reliability thanks to XtraDensiFill resin encapsulation Ambient temperature max. 70 C 70 C 70 C 70 C 70 C 70 C Coil shell in 2-chamber technology Safety and protection Self-extinguishing potting and hood material Type encapsulated encapsulated encapsulated encapsulated encapsulated encapsulated Class of Insulation System VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 Applications Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) II II II II II II As a mains transformer for adjustment of the voltage and simple electrical isolation. Short circuit strength inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit proof proof proof proof proof proof As a safety transformer for the safe electrical isolation of the input and output sides. The transformer is suitable for creating SELV and PELV circuits because Order numbers of the limit on the output voltage. Order Number refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output voltage voltage voltage voltage voltage voltage Circuit Diagram Standards & 1 Certifications W Mains transformer UL 5085-1/-2, CSA 22.2 No.66 to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 202 subject to change - +PCB Transf Or mers Short circuit proof PCB transformer Short circuit proof PCB transformer AVB AVB Type AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/.. General Data Input Rated input Voltage 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac Rated input voltage 2 x 115 Vac Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz Rated output voltage 6 - 2 x 24 Vac Output Rated power 0.35 - 3.2 VA Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6 2x6 Vac: AVB 0,5/2/6 2x6 Vac: AVB 1,0/2/6 2x6 Vac: AVB 1,5/2/6 2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6 Insulation class B 2x2 Vac: AVB 0,35/2/9 2x8 Vac: AVB 0,5/2/8 2x9 Vac: AVB 1,0/2/9 2x8 Vac: AVB 1,5/2/8 2x8 Vac: AVB 2,3/2/8 2x12 Vac: AVB 0,35/2/12 2x9 Vac: AVB 0,5/2/9 2x12 Vac: AVB 1,0/2/12 2x9 Vac: AVB 1,5/2/9 2x9 Vac: AVB 2,3/2/9 Maximum ambient temperature 70 C 2x15 Vac: AVB 0,35/2/15* 2x12 Vac: AVB 0,5/2/12 2x15 Vac: AVB 1,0/2/15 2x12 Vac: AVB 1,5/2/12 2x12 Vac: AVB 2,3/2/12 2x18 Vac: AVB 0,35/2/18* 2x15 Vac: AVB 0,5/2/15* 2x18 Vac: AVB 1,0/2/18* 2x15 Vac: AVB 1,5/2/15 2x15 Vac: AVB 2,3/2/15 2x24 Vac: AVB 0,35/2/24* 2x18 Vac: AVB 0,5/2/18* 2x24 Vac: AVB 1,0/2/24* 2x18 Vac: AVB 1,5/2/18* 2x18 Vac: AVB 2,3/2/18* Efficiency up to 59 % 2x24 Vac: AVB 0,5/2/24* 2x24 Vac: AVB 1,5/2/24* 2x24 Vac: AVB 2,3/2/24* Degree of protection IP 00 1.1 Rated Power 0.35 VA 0.50 VA 1.00 VA 1.50 VA 2.00 VA 2.30 VA No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43 No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W Advantages Efficiency 30 % 40 % 55 % 57 % 0 % 59 % Minimum size at high output Standards Unconditionally short-circuit proof Classification Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Double input voltage for series or parallel connection *Mains transformer *Mains transformer *Mains transformer *Mains transformer *Mains transformer Also with double output voltage for series or parallel connection Approvals Designed for high ambient temperatures Approvals cURus cURus cURus cURus cURus cURus 1.21.2 Permanent corrosion protection, high insulation value and maximum Environment electrical reliability thanks to XtraDensiFill resin encapsulation Ambient temperature max. 70 C 70 C 70 C 70 C 70 C 70 C Coil shell in 2-chamber technology Safety and protection Self-extinguishing potting and hood material Type encapsulated encapsulated encapsulated encapsulated encapsulated encapsulated Class of Insulation System VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 Applications Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) II II II II II II As a mains transformer for adjustment of the voltage and simple electrical isolation. Short circuit strength inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit proof proof proof proof proof proof As a safety transformer for the safe electrical isolation of the input and output 1.3 sides. The transformer is suitable for creating SELV and PELV circuits because Order numbers of the limit on the output voltage. Order Number refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output voltage voltage voltage voltage voltage voltage Circuit Diagram 1.4 Standards & 1 Certifications W 1.5 Mains transformer UL 5085-1/-2, CSA 22.2 No.66 to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 subject to change 203 - +