1-Channel circuit breaker EB-0824-100-0 Advantages Automatic feedthrough of all signal levels Optional communication via communication module Optional undervoltage shutdown in combined network Optional settings for tripping current Additional load outputs through output distribution modules mountable side by side Selective load-dependent activation Versions with collective reset input Applications EB-27 Electronic circuit breaker with thermomagnetic characteristic with alarm signal forwarded for tripped and switched off channels to the connected channels. Starter version with fuse for 24 V loads. EB-28 Electronic circuit breaker with current-limiting characteristic with alarm signal forwarded for tripped and switched off channels to the connected channels. Starter version with fuse for 24 V loads if active current limitation is required. EB-08, EB-18, EB-38 Electronic circuit breaker with current-limiting characteristic and comprehensive communication with the connected modules. Suitable as advanced fuse for 24 V loads with option of reading more detailed current supply parameters and actively controlling the channels. Picture shows EB-XX24-XX0-0 Approvals W U Z Standards Z Safety: UL 508 (prepared), UL 2367 (prepared), GL (prepared), EN 60950-1, EN 50178, EN/IEC 60204-1 VW eCl ss No.27-37-18-02 (prepared) EMC: EN 61000-6-2 (interference immunity), EN 61000-6-3 (emitted interference) CE: Acc. to 2014/30/EU 1-Channel circuit breaker EB-0824-100-0 Type EB-0824-100-0 Type EB-0824-100-0 Special features Terminal and mounting Characteristics Adjustable tripping currents Terminals input, (spring clamp terminal) max. 16 mm max 2.5 mm (1 x) Terminals output, (spring clamp terminal) Input Terminals signalling, (spring clamp terminal) max. 2,5 mm 24 Vdc Input rated voltage Mounting position Input voltage range 18 - 30 Vdc Measures and weights 3 % Maximal residual ripple of supplied input voltage Weight 0.042 kg Max. total input current 10 A 10 A (-), 40 A (+) Max. input current for each pole of terminal 17.5 V (Turn-off Threshold 16.7 V), Required input voltage for turning-on of outputs 0.7 V 0.4 W Max. power losses 61.2 14.8 Over voltage protection Suppressor diode 33 V 53.7 39 mA 24 V Stand-by current 0.3 W 24 V Power losses in stand-by mode 50-110 mF Turn on capacity 24 Vdc/ 2,5 mm/2,5 m Output 99.3 Output rated voltage 24 Vdc 130 mV Maximum voltage drop between input and output Initialization time of module 52 ms 51.7 min. 50 ms / max. 5 s Turn-on delay of outputs Waiting periode after switch-off of an output 500 ms (Short circuit) 5 s (Overload) Parallel use of outputs Not allowed not allowed Serial use of outputs 64.5 Resistance to reverse feed max. 35 Vdc 12.0 0.5 - 10 A, adjustable Output rated current Efficiency 99.0 % typ. rated current x 1,25 ( 1-10 A) Output limited current typ. rated current x 2,5 ( 0,5 A) Signaling Read:-state (tripped, On, Off) -set/current Bus communication -input voltage -firmware version/serial number Write:-state (on, off, reset) LED (red, green, orange) Status indicator Output status, short circuit proof Signal output high = Channel on, low = Channel off, fault Reset input Signal output (ON/OFF/Reset) Level high = min. 15V, max. 30V Level low = min. 0V, max. 5V Environment Type of cooling Natural convection -25 C to +70 C Ambient temperature Storage temperature -25 C ... +85 C Derating max. +60 C > 6A 5 96 %, without condensation Relative humidity Required minimum spacing (left/right) 0 mm 30 mm Required minimum spacing (over/under) Safety and protection Protection index IP 20 III, without PE connection Safety class Degree of pollution 2 Order numbers EB-0824-100-0 Order Number - + 30 Subject to change.