1-Channel circuit breaker EB-1824-010-0 Advantages Automatic feedthrough of all signal levels Optional communication via communication module Optional undervoltage shutdown in combined network Optional settings for tripping current Additional load outputs through output distribution modules mountable side by side Selective load-dependent activation Versions with collective reset input Applications EB-27 Electronic circuit breaker with thermomagnetic characteristic with alarm signal forwarded for tripped and switched off channels to the connected channels. Starter version with fuse for 24 V loads. EB-28 Electronic circuit breaker with current-limiting characteristic with alarm signal forwarded for tripped and switched off channels to the connected channels. Starter version with fuse for 24 V loads if active current limitation is required. EB-08, EB-18, EB-38 Electronic circuit breaker with current-limiting characteristic and comprehensive communication with the connected modules. Suitable as advanced fuse for 24 V loads with option of reading more detailed current supply parameters and actively controlling the channels. Picture shows EB-XX24-XX0-0 Approvals W U Z Standards Z Safety: UL 508 (prepared), UL 2367 (prepared), GL (prepared), EN 60950-1, EN 50178, EN/IEC 60204-1 VW eCl ss No.27-37-18-02 (prepared) EMC: EN 61000-6-2 (interference immunity), EN 61000-6-3 (emitted interference) CE: Acc. to 2014/30/EU 1-Channel circuit breaker EB-1824-010-0 Type EB-1824-010-0 Type EB-1824-010-0 Special features Terminal and mounting Characteristics - Terminals input, (spring clamp terminal) max. 16 mm max 2,5 mm (1 x) Terminals output, (spring clamp terminal) Input Terminals signalling, (spring clamp terminal) max. 2,5 mm 24 Vdc Input rated voltage Mounting position Input voltage range 18 - 30 Vdc Measures and weights 3 % Maximal residual ripple of supplied input voltage Weight 0,042 kg Max. total input current 1 A 10 A (-), 40 A (+) Max. input current for each pole of terminal 17.5 V (Turn-off Threshold 16.7 V), Required input voltage for turning-on of outputs 0.7 V 1,2 W Max. power losses 61.2 14.8 Over voltage protection Suppressor diode 33 V 53.7 39 mA 24 V Stand-by current 1,17 W 24 V Power losses in stand-by mode Turn on capacity 110 mF 24 Vdc / 2,5 mm / 2,5 m Output Output rated voltage 24 Vdc 99.3 Maximum voltage drop between input and output 58 mV 52 ms Initialization time of module Turn-on delay of outputs min. 50 ms / max. 5 s 51.7 500 ms (Short circuit) 5 s (Overload) Waiting periode after switch-off of an output Parallel use of outputs Not allowed Serial use of outputs not allowed 35 Vdc Resistance to reverse feed max. 64.5 12.0 Output rated current 1 A 99.0 % Efficiency Output limited current typ. 1,25 A Signaling Read:-state (tripped, On, Off) -set/active current -input voltage Bus communication -firmware version/serial number Write:-state (on, off, reset) LED (red, green, orange) Status indicator Output status, short circuit proof Signal output high = Channel on, low = Channel off, fault Reset input Signal output (ON/OFF/Reset) Level high = min. 15V, max. 30V Level low = min. 0V, max. 5V Environment Type of cooling Natural convection -25 C +70 C Ambient temperature Storage temperature -25 C ... +85 C - Derating Relative humidity 5 96 %, without condensation Required minimum spacing (left/right) 0 mm 30 mm Required minimum spacing (over/under) Safety and protection IP 20 Protection index III, without PE connection Safety class Degree of pollution 2 Order numbers Order Number EB-1824-010-0 - + 30 Subject to change.