Single- and two phases, primary switched mode power supply PC-0224-050-0 Advantages Stabilised and adjustable output voltage Fast tripping of standard bi-metal circuit breakers DC OK signal contact Parallel operation Push-in terminals Robust DIN rail mounting Resistant to transient overvoltages up to 4 kV Applications The economic power supplies in the Power Compact series set new standards in their class. Above-average robustness against transients and energetic surge pulses at their input and equipped with essential additional aspects for a worldwide high plant availability. A powerful and flexible option that s still light and compact. Due to a single or two-phase supply from 180 V to 550 V, these power supplies are suitable for a highly diverse range of applications in solar, measurement and control technology and they really come into their own in industrial and building automation. The output voltage can be set easily using the rotary potentiometer on the front of the housing. The robust DIN rail fastening method and push-in connection terminals enable fast and secure mounting. Picture shows PC-0224-050-0 Approvals W o Z Standards Z Primary switched mode power supply UL/CSA 60950, UL 508, GL (in preparation) to UL 60950, UL 508 Safety: EN 61558-2-16, EN 60950-1 EMC: EN 61204-3 Single- and two phases, primary switched mode power supply PC-0224-050-0 Type PC-0224-050-0 Type PC-0224-050-0 Input Input Input rated voltage 200 - 500 Vac Connections input (direct plug-in technology Push- max 2,5 mm In) 180 - 550 Vac Input voltage range (254 - 780 Vdc) Output -0.5 %/Vac < 200 Vac Connections output (direct plug-in technology Push- Input voltage derating max 2,5 mm (-0.4 %/Vdc < 280 Vdc) In) Rated frequency range 44 Hz - 66 Hz / 0 Hz Signaling 1.25 A (200 Vac) / 0.67 A (500 Vac) Input rated current (rated load) Connections signalling (direct plug-in technology max 2,5 mm Starting current limiter < 30 A, NTC Push-In) Switch-on time 0.98 s (200 Vac) / 0.47 s (500 Vac) Environment 15 ms (200 Vac) / 126 ms (500 Vac) Mains buffering horizontal for standard rail DIN TH 35 Mounting position Power factor 0.52 Measures and weights 3.15 A Input fuse internal Weight 0.60 kg 6 A, 10 A, 16 A, Recommended back-up fuse (circuit breaker) 42 x 127 x 126 mm characteristic B, C Dimensions W x H x D Varistor Transient surge voltage protection Output 24 Vdc Output rated voltage 23 28.5 Vdc Output voltage range Output rated current 5 A typ. 5.5 A (constant current) Output limited current 127.0 Tripping of LS circuit breakers max. B4 Yes Parallel connection Yes Serial operation 0.94 W / 16.36 W (230 Vac) 63.5 Power dissipation, no load/rated load 1.35 W / 14.55 W (400 Vac) Max. power losses 18.2 W (200 Vac / 24 V / 5 A) typ. 89 % Efficiency 3.0 42.0 typ. 30 mVss Ripple factor Resistance to reverse feed max. 35 Vdc max. 40 Vdc Over-voltage-protection Signaling Status indicator LED green Relay contact Signal output Approvals cURus, cULus, GL (prepared) Approvals Environment Cooling method natural convection -25 C ... +70 C Ambient temperature Storage temperature -25 C ... +85 C Derating -2.5 %/K > +55 C 0 mm Required minimum spacing (left/right) Required minimum spacing (over/under) 50 mm Safety and protection IP 20 Protection index Safety class I, with PE connection Order numbers Order Number PC-0224-050-0 126.0 118.5 G - + 30 Subjects to change.