Features Applications n Size: 11.8 mm diameter, n Telecommunications equipment 12 mm length n Industrial equipment/electronics n 60 kA surge rating n High power handling n Low leakage n RoHS compliant* n UL Recognized 2061 SeriesHigh-Current 2-Electrode Gas Discharge Tube Characteristics Test Methods per ITU-T K.12 and IEC 61643-311. Model No. Characteristic 2061-23 2061-25 2061-30 2061-35 2061-42 DC Sparkover 20 % 100 V/s 230 V 250 V 300 V 350 V 420 V (1) Impulse Sparkover 100 V/s < 600 V < 600 V < 700 V < 800 V < 900 V 1000 V/s < 700 V < 700 V < 800 V < 900 V < 1000 V Model No. Characteristic 2061-47 2061-60 2061-70 2061-80 DC Sparkover 20 % 100 V/s 470 V 600 V 700 V 800 V (1) Impulse Sparkover 100 V/s < 900 V < 1100 V < 1200 V < 1300 V 1000 V/s < 1100 V < 1300 V < 1400 V < 1500 V (1) Impulse Sparkover voltage is defined as typical values of distribution. (2) Insulation Resistance (IR) ....................................100 / 250 Vdc ........................................................ > 1 GW Glow Voltage ...........................................................10 mA ..................................................................... ~ 70 V Arc Voltage ..............................................................1 A .......................................................................... ~ 10 V Glow-Arc Transition Current .................................................................................................................... < 1 A Maximum Capacitance ............................................1 MHz ..................................................................... < 10 pF Maximum Impulse Discharge Current .....................60,000 A, 8/20 s .................................................. 1 operation 40,000 A, 8/20 s ................................................... 5 operations Nominal Alternating Discharge Current ...................40 A, 50 Hz, 1 second ............................................ 1 operation 200 A, 9 cycles ...................................................... 1 operation Impulse Life ............................................................500 A, 10/1000 s .................................................. > 400 operations (3) DC Holdover Voltage ........................................................................................................................... < 150 ms Operating Temperature ............................................................................................................................ -30 to +85 C Storage Temperature ............................................................................................................................... -40 to +115 C Climatic Category (IEC 60068-1)............................................................................................................. 40 / 90 / 21 Notes: The 2061 Series is NOT intended for use as a surface mount component. UL Recognized component, UL File E313168. At delivery AQL 0.65, level II DIN ISO 2859 (2) DC Sparkover Voltage IR Measuring Voltage 230400 V 100 V 420800 V 250 V (3) Network Applied DC Sparkover Voltage DC Holdover Voltage 230250 V 135 V 300800 V 150 V *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. *RoHS COMPLIANT VERSIONS AVAILABLE *RoHS COMPLIANT LEAD FREE LEAD FREE VERSIONS ARE RoHS COMPLIANT* 2061 SeriesHigh-Current 2-Electrode Gas Discharge Tube Product Dimensions How to Order 2061 - xx - A LF Model Number Designator Voltage (Divided by 10) 23 = 230 V 47 = 470 V 25 = 250 V 60 = 600 V 30 = 300 V 70 = 700 V 35 = 350 V 80 = 800 V 12.0 0.3 42 = 420 V (.472 .012) Leads A = No Leads Packaging (Blank) = Bulk Packaging - 60 pcs./tray (Standard) RoHS Compliancy LF = RoHS Compliant Product 11.8 0.2 Packaging Specifications (.465 .008) Model 2061 ships standard bulk, 60 pcs. per tray. 180 pcs. per box. MM DIMENSIONS: (INCHES) REV. F 07/16 Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications.