Features This series is currently available but n Radial Leaded Devices not recommended for new designs. n Maximum 600 VAC interrupt fault rating n Available in matched resistance bins n Ability to withstand lightning surges n RoHS compliant* n Ability to withstand AC power cross n Agency recognition: conditions MF-R/600 Series - Telecom PTC Resettable Fuses Electrical Characteristics Max. One Hour Max. Time Tripped Hold Trip Interrupt Initial Resistance Post-Trip To Trip Power Max. Current Current Ratings Resistance 1 A Dissipation Operating Model Voltage Amps Amps Ohms Ohms Ohms Seconds Watts Volts Amps at 23 C at 23 C at 23 C at 23 C at 23 C at 23 C at 23 C (V ) DC Max. Max. Min. Max. Max. MF-R015/600 250 600 3 0.15 0.30 6.0 12.0 22.0 5.0 1.0 MF-R015/600-A 250 600 3 0.15 0.30 7.0 10.0 20.0 5.0 1.0 MF-R015/600-B 250 600 3 0.15 0.30 9.0 12.0 22.0 5.0 1.0 MF-R015/600-F 250 600 3 0.15 0.30 7.0 12.0 22.0 5.0 1.0 MF-R016/600 250 600 3 0.16 0.32 4.0 10.0 18.0 7.0 1.0 MF-R016/600-A 250 600 3 0.16 0.32 4.0 7.0 16.0 7.0 1.0 MF-R016/600-1 250 600 3 0.16 0.32 4.0 8.0 17.0 7.0 1.0 Environmental Characteristics Operating/Storage Temperature ........................... -40 C to +85 C Maximum Device Surface Temperature in Tripped State ................................................. 125 C Passive Aging ....................................................... +60 C, 1000 hours ............................................... 15 % typical resistance change Humidity Aging...................................................... +60 C, 90 % R.H. 1000 hours ............................. 15 % typical resistance change Solvent Resistance ............................................... MIL-STD-202, Method 215B ................................. No change Lead Solderability ................................................. ANSI/J-STD-002 Flammability ......................................................... IEC 695-2-2 .......................................................... No flame for 60 secs. Vibration ............................................................... MIL-STD-883C, Method 2007.1, Condition A ....... No change Test Procedures And Requirements For Model MF-R/600 Series Test Test Conditions Accept/Reject Criteria Visual/Mech........................................................ Verify dimensions and materials ........................... Per MF physical description Resistance ............................................................ In still air 23 C ................................................. Rmin R Rmax Time to Trip ........................................................... 1 A, Vmax, 23 C .................................................. T max. time to trip (seconds) Hold Current ......................................................... 30 min. at Ihold ..................................................... No trip Trip Cycle Life ....................................................... Vmax, Itrip, 100 cycles .......................................... No arcing or burning Trip Endurance ..................................................... Vmax, 24 hours ..................................................... No arcing or burning UL File Number .................................................... E307915 TV File Number .................................................. R 50256529 Thermal Derating Chart - I (Amps) hold Ambient Operating Temperature Model -40 C -20 C 0 C 23 C 40 C 50 C 60 C 70 C 85 C MF-R015/600 0.233 0.206 0.178 0.150 0.124 0.110 0.096 0.083 0.062 MF-R016/600 0.249 0.219 0.190 0.160 0.132 0.117 0.103 0.088 0.066 I is approximately two times I . trip hold WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov *RoHS Directive 2015/863, Mar 31, 2015 and Annex. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.Applications Customer Premise Equipment (CPE): n Modems n Cable modems n Fax machines n POS equipment n Security equipment n Set top boxes MF-R/600 Series - Telecom PTC Resettable Fuses Product Dimensions Physical Characteristics A B C D E Model Max. Max. Max. Min. Nom. Style Lead Dia. Material 13.5 12.6 6.0 4.7 5.0 0.65 MF-R015/600 1 Sn/Cu (0.531) (0.496) (0.236) (0.185) (0.197) (0.026) 16.0 12.6 6.0 4.7 5.0 0.65 MF-R016/600 1 Sn/Cu (0.629) (0.496) (0.236) (0.185) (0.197) (0.026) MM Packaging options: BULK: 300 pcs. per bag. TAPE & REEL: 600 pcs. per reel. DIMENSIONS: (INCHES) Longer lead lengths available upon request. Typical Part Marking How to Order A C Represents total content. Layout may vary. MF - R 015/600 - A 05 - 2 Multifuse MANUFACTURER S Product TRADEMARK Designator PART B IDENTIFICATION Series R015 R = Radial Leaded DATE CODE 24001K MFG. LOCATION Component (FIRST DIGIT = (K = KOREA Hold Current, Ihold LAST DIGIT OF YEAR S = CHINA 015-016 (0.15 - 0.16 Amps) SECOND DIGIT = T = TAIWAN) Max. Interrupt Voltage, V MONTH NEXT THREE DIGITS = Resistance Range LOT CODE) D E Narrow resistance ranges are available on all models as defined in Electrical Characteristics. Typical Time to Trip at 23 C Blank = N/A Resistance Bins 1000 Narrow resistance ranges can be separated into packages where each device is within 0.5 ohms of each other. Blank = N/A MF-R016/600 Packaging Options 100 - 0 = Bulk Packaging - 2 = Tape and Reel* *Packaged per EIA486-B MF-R015/600 10 1 0.10 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Fault Current (Amps) Resistance Options Model Rmin. Rmax. R1Max. Bin MF-R015/600 6.0 12.0 22.0 N/A MF-R015/600-A 7.0 10.0 20.0 0.5 MF-R015/600-B 9.0 12.0 22.0 0.5 MF-R015/600-F 7.0 12.0 22.0 0.5 MF-R016/600 4.0 10.0 18.0 N/A MF-R016/600-A 4.0 7.0 16.0 0.5 MF-R016/600-1 4.0 8.0 17.0 0.5 MF-R/600, REV. O, 03/19 Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. Time to Trip (Seconds)