TISP61089D, TISP61089SD, TISP61089AD, TISP61089ASD DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS TISP61089 Gated Protector Series Overvoltage Protection for Negative Rail SLICs Agency Recognition Dual Voltage-Tracking Protectors Description - 61089 for Battery Voltages to ............................................. -75 V - 61089A for Battery Voltages to......................................... -100 V UL File Number: E215609 - Low Gate Triggering Current ............................................ < 5 mA - High Holding Current .................................................... > 150 mA 2/10 Overshoot Voltage Specified Rated for GR-1089-CORE and K.44 Impulses I = 100 A, 2/10 PP Impulse Wave Shape I Element PPSM V A VoltageCurrent Diode8 2/10 2/10 120 SCR 12 10/700 5/31040 10/1000 10/100030 Package Options - Surface Mount 8-pin Small-Outline Line Feed-Thru Connection (D) ................................................. UL Recognized Components Shunt Version Connection (SD) D Package Top View and Device Symbol for Feed-Thru Pin-Out K1 K1 (Tip) K1 1 8K1 (Tip) (Gate) G 2 7 A (Ground) NC 3 6 A (Ground) A G (Ring) K2 45 K2 (Ring) A NC - No internal connection Terminal typical application names shown in K2 K2 parenthesis MD6XBDa SD6XAEB D Package Top View and Device Symbol for Shunt (SD) Pin-Out K1 (Tip) K1 1 8NC (Gate) G 2 7 A (Ground) A NC 3 6 A (Ground) G (Ring) K2 45 NC A MD6XBE NC - No internal connection Terminal typical application names shown in K2 parenthesis SD6XAU How to Order Device Package CarrierDOrder As evicePackage Carrier Order As TISP61089D (Small-Outline) R TISP61089DR-S TISP61089A D (Small-Outline) R TISP61089ADR-S TISP61089SD (Small-Outline) R TISP61089SDR-S TISP61089ASD (Small-Outline) R TISP61089ASDR-S Carrier R is Embossed Tape Reeled Carrier R is Embossed Tape Reeled NOVEMBER 1995 REVISED JULY 2019 *RoHS Directive 2015/863, Mar 31, 2015 and Annex. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. WARNING Cancer and Reproductive Harm The products described herein and this document are subject to specific legal disclaimers as set forth on the last www.P65Warnings.ca.gov page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. TISP61089 Gated Protector Series Description These 61089 parts are all dual forward-conducting buffered p-gate thyristor (SCR) overvoltage protectors. They are designed to protect monolithic SLICs (Subscriber Line Interface Circuits) against overvoltages on the telephone line caused by lightning, a.c. power contact and induction. The 61089 limits voltages that exceed the SLIC supply rail voltage. The 61089 parameters are specified to allow equipment compliance with Telcordia (formally Bellcore) GR-1089-CORE and ITU-T recommendations K.20, K.21 and K.45. The SLIC line driver section is typically powered from 0 V (ground) and a negative (battery) voltage. The protector gate is connected to this negative supply. This references the protection (clipping) voltage to the negative supply voltage. The protection voltage will then track the negative supply voltage and the overvoltage stress on the SLIC is minimized. Positive overvoltages are clipped to ground by diode forward conduction. Negative overvoltages are initially clipped close to the SLIC negative supply rail value. If sufficient current is available from the overvoltage, then the protector SCR will switch into a low voltage on-state condition. As the overvoltage subsides the high holding current of 61089 SCR helps prevent d.c. latchup. The 61089 is intended to be used with a series resistance of at least 25 and a suitable overcurrent function for Telcordia compliance. Power fault conditions require a series overcurrent element which either interrupts or reduces the circuit current before the 61089 current rating is exceeded. For equipment compliant to ITU-T recommendations K.20 or K.21 or K.45 only, the series resistor value is set by the coordination requirements. For coordination with a 400 V limit GDT, a minimum series resistor value of 10 is recommended. The 61089 buffered gate design reduces the loading on the SLIC supply during overvoltages caused by power cross and induction. The regular pin-out for surface mount and through-hole packages is a feed through configuration. Connection to the SLIC is made via the 61089, Ring through pins 4 - 5 and Tip through pins 1 - 8. A non-feed-through surface mount (D) package is available. This shunt (SD) version pin-out does not make duplicate connections to pin 5 and pin 8 which increases package creepage distance from ground of the other connections from about 0.7 mm to over 3 mm. High voltage ringing SLICs, with battery voltages below -100 V and down to -155 V, can be protected by the TISP61089B device. Details of this device are in the TISP61089B data sheet. Absolute Maximum Ratings, -40 C T 85 C (Unless Otherwise Noted) J Rating Symbol Value Unit 61089 -100 Repetitive peak off-state voltage, V = 0 V V GK DRM 61089A -120 61089 -85 Repetitive peak gate-cathode voltage, V = 0 V V KA GKRM 61089A -120 Non-repetitive peak on-state pulse current (see Notes 1 and 2) 10/1000 s (Telcordia (Bellcore) GR-1089-CORE, Issue 2, February 1999, Section 4) 30 I A 5/320 s (ITU-T K.20, K.21& K.45, K.44 open-circuit voltage wave shape 10/700 s) 40 PPSM 1.2/50 s (Telcordia (Bellcore) GR-1089-CORE, Issue 2, February 1999, Section 4) 100 2/10 s (Telcordia (Bellcore) GR-1089-CORE, Issue 2, February 1999, Section 4) 120 Non-repetitive peak on-state current, V = -75 V, 50 Hz to 60 Hz (see Notes 1 and 2) GG 0.1 s 11 1 s 4.8 I A TSM 5 s 2.7 300 s 0.95 900 s 0.93 Non-repetitive peak gate current, 1/2 s pulse, cathodes commoned (see Notes 1 and 2) I +40 A GSM Operating free-air temperature range T -40 to +85 C A Junction temperature T -40 to +150 C J Storage temperature range T -40 to +150 C stg NOTES: 1. Initially the protector must be in thermal equilibrium with -40 C T 85 C. The surge may be repeated after the device returns J to its initial conditions. Gate voltage ranges are -20 V to -75 V for the 61089 and -20 V to -100 V for the 61089A. 2. The rated current values may be applied either to the Ring to Ground or to the Tip to Ground terminal pairs. Additionally, both terminal pairs may have their rated current values applied simultaneously (in this case the Ground terminal current will be twice the rated current value of an individual terminal pair). Above 85 C, derate linearly to zero at 150 C lead temperature. NOVEMBER 1995 REVISED JULY 2019 Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.