ATS Series Anti-Tampering Detect Switches Features/Benefits Typical Applications Normally closed function Smart meters Vertical detect Alarm systems Reliable long time compression Anti-tamper devices IP54 Tape & reel RoHS compliant and compatible Specifications Electrical GOLD SILVER FUNCTION: Momentary action. MAXIMUM POWER: 0.2 VA 1 VA CONTACT TYPE: SPST Normally Closed. MAXIMUM VOLTAGE: 32 VDC 32 VDC TERMINALS: Gullwing type for SMT. MINIMUM VOLTAGE: 20 mVDC 20 mVDC MAXIMUM CURRENT: 10 mA 50 mA Mechanical MINIMUM CURRENT: 1 A 1 mA SWITCHING FORCE: 2 N CONTACT RESISTANCE: 350 m TRAVEL TO BREAK: 0,7 mm INSULATION RESISTANCE: > 1 G TOTAL TRAVEL: 1,1 mm DIELECTRIC STRENGTH: 250 Vrms Packaging Environmental GOLD SILVER Switches are delivered on continuous tape, in reels of 2,000 pieces OPERATING TEMPERATURE: 40C to +125C 40C to +85C STORAGE TEMPERATURE: 55C to + 125C 40C to +85C Process SOLDERING: Compatible with lead free reflow process NOTE: Specifications listed above are for switches with standard options. For information on specific and custom switches, consult Customer Service Center. Build-A-Switch To order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on the next page. For additional options not shown in catalog, consult Customer Service Center. A T S 2 D G N C L F Actuator 2 Soft actuator - height 3.20 mm E Operating Force LFS Lead free compatible. Silver Plated D 2 N detect LFG Lead free compatible. Gold Plated Contact Material 1 Silver 3 Gold Termination Switch Function G Gull wing NC Normally closed Dimensions are shown: mm Dimensions are shown: mm Specifications and dimensions subject to change Specifications and dimensions subject to change 3 Sep 20 www.ckswitches.com www.ckswitches.com E56 E57 DetectDetect ATS Series Anti-Tampering Detect Switches SERIES 1,9 0,2 MARKING PART NUMBER D - 1 ATS 2D1G NC LFS 0,1 D - 3 ATS 2D3G NC LFG 7,3 0,15 3,2 0,25 6 AA 0,65 0,3 SECTION A-A Recommended PCB layout 6 8 CHARACTERISTICS Electrical change area The product must be activated between He (o ) min and Hm He (o ) min Hm Height measured from base of the switch E Maximum force at Hm = 6N Minimum Activation 2.1 mm Height (Hm) Switch damage can occur if product is actuated below minimum actuation height (Hm) Minimum Product height for contact opening Electrical Height 2.5 mm (He (OFF) min) Contact closing: the switch must be completely release Dimensions are shown: mm Specifications and dimensions subject to change 3 Sep 20 www.ckswitches.com E57 1,4 1 0,1 0,15 1,65 0,15 3,8