Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. CAL EI1410 NTC TEMPERATURE INDICATOR Thank you for choosing the CAL EI1410 NTC temperature indicator. * 77 x 34mm sized. F * 4 digits display. C * Easy to use by front panel keypad. * Display can be selected decimal or integer. SET * Temperature unit can be selected C or F. * Maximum and minimum measurement values are registered. * Upper and lower limits of the alarm value can be adjusted CAL EI 1410 * CE marked according to European Norms. Supply Voltage Order Code 230V AC +%10 -%20 EI1410-230VAC 12V AC/DC %10 EI1410-12 24V AC/DC %10 EI1410-24 TECHNICAL SPECIFICATIONS ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50C/-25 ... 70C 80% up to 31C decreasing linearly 50% at 40C . Max. relative humidity Rated pollution degree According to EN 60529 Front panel : IP60 , Rear panel : IP20 Height Max. 2000m Do not use the device in locations subject to corrosive and flammable gases. ELECTRICAL CHARACTERISTICS 230V AC +%10 -%20, 50/60Hz or 24V AC/DC %10, 50/60Hz or 12V AC/DC %10, 50/60Hz Supply Power consumption Max. 5 VA Wiring 2.5mm screw-terminal connections Scale Decimal -50.0C...110.0C -50C...110C Integer Sensitivity 0.1C 1C Accuracy EMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. The device is designed to operate in controlled electromagnetic environment) Safety requirements EN 61010-1: 2001 (Pollution degree 2, overvoltage category II) HOUSING Housing type Suitable for panel mounting. Dimensions W77xH34xD70mm Weight EI1410-230 Approx. 250g (after packing) EI1410-24 Approx. 150g (after packing) Enclosure material Self extinguishing plastics. While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. CAL CONTROLS LTD Bury Mead Road, Hitchin, Herts, SG5 1RT, UK. Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales cal-controls.co.uk Web : www.cal-controls.com 1/3 EI1410-E-03www.cal-controls.com Input UP.l1 UP.l1 -HYS LO.l1 +HYS LO.l1 t Alarm t When alarm case happens, process value flashes. DIMENSIONS Depth 85mm 8mm 70mm For removing mounting clamps: F - Push up the flush-mounting C clamp in direction 1 as SET 1 shown in the figure left. - Then, pull out the clamp in direction 2. CAL EI 1410 2 Flush mounting Panel Rubber clamp gasket Note : 1) Panel thickness should be maximum 7mm. 2) If there is no 60mm free space at back side of the device,it would be difficult to remove it from Panel cut-out the panel. 71mm Equipment is protected througout by DOUBLE INSULATION. Holding screw 0.4-0.5Nm NOTE : Fuse 1) Mains supply cords shall meet the requirements of SUPPLY: F 100 mA Switch IEC 60227 or IEC 60245. 250V AC 7 Line 184-253V AC 2) In accordance with the safety regulations, the power 230V AC 50/60Hz 3VA 8 Neutral Supply supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator. Fuse should be connected. Cable size: 1,5mm CONNECTION DIAGRAM CAL EI1410 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of electrcal power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. The installation and electrical connections must be carried out by qualified staff and must be according to the relevant locally applicable regulations. www.cal-controls.com www.cal-controls.com EI1410-230VAC EI1410-24 NTC TEMPERATURE INDICATOR NTC TEMPERATURE INDICATOR SN: XXXXXXXXX SN: XXXXXXXXX NTC NTC SENSOR SENSOR 24V AC/DC 10% 230V AC +10% -20% 50/60Hz 5VA 50/60Hz 5 VA W R W R 123456 789 10 11 12 123456 789 10 11 12 2/3 EI1410-E-03 34mm 29mm EI1410-230VAC NTC TEMPERATURE INDICATOR SN: XXXXXXXXX NTC SENSOR 230V AC +10% -20% 50/60Hz 5 VA W R 123456 789 10 11 12