ETC1311-FE-230VAC DIGITALT THERMOSTAT SN: XXXXXXXXX J (Fe-CuNi) - + 123456 789 10 11 12 www.cal-controls.com COMPRESSORHEAT OUT 1/2HP250V240VAC 8AAC Cos = 0.4 8RESISTIVEA 250V AC CosLOAD = 1 230V AC +10% -20% 50/60Hz 3VA Technical Specifications ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50C/-25 ... 70C (with no icing) Max. relative humidity 80%, up to 31C decreasing linearly 50% at 40C Rated pollution degree According to EN 60529 Front panel : IP60 Rear panel : IP20 CAL ETC1311 DIGITAL THERMOSTAT Height Max. 2000m Thank you for choosing the CAL ETC1311 thermostat. Do not use the device in locations subject to corrosive and flammable gasses. * 34 x 77mm sized. ELECTRICAL CHARACTERISTICS * On-Off control. Supply voltage 230V AC +%10 -%20, 50/60Hz or 12VAC or 24 AC%10, 50/60Hz or optional 9-30V DC %10 . * J type Thermocouple or Pt100 input. Power consumption Max. 3VA OUT * Temperature compensation. Wiring 2.5mm screw-terminal connections. C Scale 0 .... +600C for J Type. -100.... +600C for Pt100 * In the case of probe failure, heating can be Accuracy 0.5% (of full scale) 1 digit selected on, off or periodical running. PRG Indicator 3 digits, 14mm, 7 parts red LED * Upper and lower limits of the setpoint can be EMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. adjusted. The device is designed to operate in controlled electromagnetic environment) * Set value can be adjusted by using single key. CAL ETC1311 Safety requirements EN 61010-1: 2001 (Pollution degree 2, overvoltage category II) * CE marked according to European Norms. OUTPUT Order Code : ETC1311- - - HEAT OUT For ETC1311-XX-XX Relay: 250V AC, 8A(for resistive load), NO+NC. 12 3 For ETC1311-FE-XXP Relay: 240V AC, 16A(for resistive load), NO. 1 - Input 3 - Output 2 - Supply Voltage For ETC1311-XX-XX Mechanical 30.000.000 Electrical 100.000 operation. Life expectancy for relay For ETC1311-FE-XXP Mechanical 30.000.000 Electrical 30.000 operation. FE.....J Type P..........Relay-16A 230VAC...230V AC R.......Pt100 24VAC.....24V AC None...Relay-8A CONTROL 12VAC.....12V AC Control type Single-setpoint control SM...........9-30V DC SMPS Control algorithm On-Off control Hysteresis Adjustable between 1 ... 20C. HOUSING Connecton Dagram Housing type Suitable for panel mounting. CAL ETC1311 is intended for installation in control panels. Make sure that the device is Dimensions W77xH34xD70mm used only for intended purpose. The electrical connections must be carried out by Weight Approx. 250g (after packing the device and a probe) Self extinguishing plastics qualified staff and must be according to the relevant locally applicable regulations. During Enclosure material an installation, all of the cables that are connected to the device must be free of electrical While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should Dimensions not be close to the power cables or components. Depth 85mm 8mm 70mm www.cal-controls.com www.cal-controls.com www.cal-controls.com For removing mounting clamps: OUT ETC1311-FE-230VAC ETC1311-FE-230VAC-P ETC1311-R-12VAC Push out the mounting clamp C DIGITAL THERMOSTAT DIGITAL THERMOSTAT DIGITAL THERMOSTAT in direction 1 as shown SN: XXXXXXXXX SN: XXXXXXXXX SN: XXXXXXXXX PRG in the figure below. Then, pull out the clamp in direction 2. CAL ETC1311 2 mounting mounting Panel Rubber J (Fe-CuNi) J (Fe-CuNi) clamp clamp gasket Pt100 1 - - + + Panel cut-out Note :1) Panel thickness 123456 789 10 11 12 123456 789 10 11 12 123456 789 10 11 12 71mm should be maximum 7 mm. Equipment is protected throughout 2) If there is no 60mm Holding screw 0.4-0.5Nm by DOUBLE INSULATION. free space at the back side of the device, it would be difficult to NOTE: Fuse Note: remove it from the SUPPLY: F 100 mA 1) Mains supply cords shall meet the requirements of Switch Panel 250V AC IEC 60227 or IEC 60245. 4 Line 184-253V AC 230V AC 2) In accordance with the safety regulations, the power 50/60Hz 3VA 5 Neutral Supply supply switch shall bring the identification of the CAL CONTROLS LTD Fuse should relevant instrument and it should be easily Bury Mead Road, Hitchin, Herts, SG5 1RT, UK. Cable size: 1,5mm be connected accessible by the operator. Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales cal-controls.co.uk Web : www.cal-controls.com 1/2 ETC1311-E-06 Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. HEAT OUT 250V AC 8A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA HEAT OUT 240V AC 16A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA HEAT OUT 250V AC 8A RESISTIVE LOAD 12V AC 10% 50/60Hz 3VA 34mm 29mmHEATING OUT LED Displayed process value in the run mode, parameter name or value in programming mode. OUT Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for C increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates. PRG Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates. CAL ETC1311 Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. PRG While holding key, setpoint value of the selected parameter appears and by using and keys the value can be adjusted. Run mode If no key is pressed Process for 3 seconds 1000100 Value 200 199 200 When pressed or key, temperature set value flashes and by using and keys the value can be adjusted. If no key is pressed for 3 seconds run mode is returned. PRG PRG If key is pressed and held for 3 seconds, If key is pressed, run mode is entered. programming mode is entered. PARAMETER TABLE Programming Mode Menu of Configuration parameters Con MIN MAX UNIT DEF.SET SeC Con Switch hysteresis for the setpoint. (When temperature 120 C 1 Hys falls to SET-HYS, output relay becomes active.) LoL 600 C 600 Upl The upper limit of the setpoint. Switch hysteresis Access code for menu of security. The lower limit of the setpoint. Fe-CuNi 0UPLC 0 for the setpoint. Enter 311 then press key. LoL Hys Cod Pt100 -99 UPL C -99 0 100 % Ect 0 Eon In the case of error, on time rate of the relay output. In the case of error, period of the relay output. 10 250 sec 30 Ect Security parameter for menu of configuration. The upper limit of the setpoint. Non= Menu is invisible. Aco Upl Offset value. -99 99 C 0 EoFs Pye= Parameters of menu are changeable. Pno= Parameters of menu are only visible. Menu of Parameter security SEC Security parameter for menu of configuration. Aco Security parameter for temperature set value. The lower limit Non= Menu is invisible. of the setpoint. Ase Pye= Set value is changeable. Lol Pye= Parameters of menu are changeable. Pno= Set value is only visible. Pno= Parameters of menu are only visible. Security parameter for temperature set value. ASE In the case of error, Pye= Set value is changeable. on time rate of Eon Pno= Set value is only visible. the relay output. In the case of error, Error Messages Ect period of the relay output. --- Means, temperature value is higher than the scale. Offset value Means, temperature value is lower than the scale. OoFs Means, temperature sensor is broken or over temperature. Pfa ETC1311-E-06 2/2