Digital Panel Meters Modular Indicator and Controller for pulse signals Type UDM60 Dual 6-DGT P-based controller with analogue indicators Dual rate, speed, frequency and period measurement Dual counter 0.001% RDG basic accuracy Range from 0.001Hz to 50kHz/20s to 1000s Scalable inputs and counters Linearization of the inputs up to 16 points Special calculation functions NPN, PNP, NAMUR, TTL, Pick-up, free of voltage contacts and AC signal inputs Up to 4 independent alarm set-points (optional) 20mA/10VDC analog output (optional) Serial port RS485 or RS232 (optional) MODBUS, JBUS communication protocol Backlighted LCD display Front protection degree: IP67, NEMA12, NEMA4xIndoor use onl Product Description How to order UDM60 XXX XX XX X XX p-based digital panel means of optional UdmSoft Model meter, dual 6-DGT LCD indi- software. UDM60 includes Slot A cator with analogue indica- storage min-max functions Slot B tors, for rate, speed, fre- and double level protection Slot C quency and period measure- password. Housing for pan- Slot D ments. Measuring ranges, el mounting with front pro- Options scaling and functions easily tection degree: IP67, programmable from the key- NEMA12, NEMA4xIndoor How to order UdmSoft-kit pad or from the PC by use onl. UdmSoft-kit: software plus communication cable for pro- gramming UDM60 by means of PC. UdmSoft: software for programming UDM60 by means of PC, downloadable from www.carlogavazzi.com. Type Selection Slot A (measuring inputs) Slot B (communication) Slot C (communication and alarm) Slot D (power supply) XX: None XX: None TF1: 0.001Hz to 50kHz for H: 90 to 260V AC/DC SX: Serial port RS485 R1: Single relay output, DC signals: PNP, L: 18 to 60V AC/DC SY: Serial port RS232 (AC1-8AAC, 250VAC) NPN, NAMUR, TTL, (24 to 48V AC/DC AV(*): Single analogue out- R2: Dual relay output, free of voltage, con- 25% according to UL) put, 0 to 20mA DC (AC1-8AAC, 250VAC) tacts, voltages up to 3: 10 to 28V DC and 0 to 10V DC R4: Dual relay output, 14VDC (12 to 24V DC 15% (AC1-8AAC, 250VAC) TF2: 0.001Hz to 50kHz for according to UL) (*): The two analogue + dual open collector AC signals: pick-up, outputs cannot be output (NPN, 100mA) voltages up to used at the same R5: 4 relay outputs (AC1- 500VAC time. It is possible to 5AAC, 250VAC) plug in only one mod- AV(*): Single analogue out- ule by instrument. put, 0 to 20mA DC and 0 to 10V DC Options XX: None TX: Tropicalization Specifications are subject to change without notice UDM60 DS ENG 090112 1UDM60 Input specifications Analogue inputs Channels and variables - latch and counter reset BQ TF1 module 2, 0.001Hz to 50kHz for DC Contact reading signal BQ TF1: <6 mA, <7 VDC signals: PNP, NPN, BQ TF2: <0.25 mA, <3 VDC NAMUR, TTL, free of volt- Close contact resistance Max 1k. age contacts, voltages up Open contact resistance Min 100k. to 14VDC. Insulation Non-insulated. BQ TF2 module 2, 0.001Hz to 50kHz for AC Accuracy (display, RS485) See table Measuring signals: pick-up, voltages accuracy, temperature up to 500VAC. drifts and minimum/maxi- ON signal minimum time mum indications duration 0.001Hz to 50kHz, 10s. Additional errors Rotation speed detection Max 1kHz, duty cycle 50%. Humidity 0.05% RDG, 60% to 90% Type of input R.H. NPN (DC) Signal level: ON < 2VDC, Magnetic field 0.05% RDG 400 A/m. OFF open collector (leak- Temperature drift See table Measuring age current <=1mA). accuracy, temperature PNP (DC) Signal level: ON >10VDC, drifts and minimum/maxi- OFF open collector (leak- mum indications age current <=1mA). NAMUR (DC) Signal level: ON <= Display 2 lines, 6-digit + 2 ana- 1mADC, OFF >= 2.2 logue indicators. mADC. 7 segments. TTL (DC) Signal level: ON >4VDC, h= 10.0 mm OFF<=2VDC. Max and min indication See table Measuring Free of voltage contact(DC) Input load: ON <1kohm, accuracy, temperature OFF >20kohm. drifts and minimum/maxi- Voltage (AC) up to 100VAC Signal level: ON > 2VAC mum indications (5.65 Vpp). Measurements Voltage (AC) up to 500VAC Signal level: ON > 9VAC Up to 1 kHz Zero-crossing detection. (25.4 Vpp). From 1 kHz Zero-crossing detection Digital inputs Included in the measuring with divisor. module. Input impedance See table Input Number of inputs 1 (contact). impedance and overflow Use - display HOLD command Overloads See table Input - key-pad disabling impedance and overflow - latch alarm reset - counter(s) reset Measurement accuracy, temp. drifts, max and min indications All accuracies and min/max indications are referred to an ambient temp. range of 25C 5C, rel. humidity 60% and scale ratio (electrical/displayed scale) equal to 1. Module Input type Accuracy Temp. drift Max indication Min indication (nn) BQ TF1 NPN (DC) 0.001% RDG 50 ppm/C 0.00000 9.99999 PNP (DC) 3 digit 00.0000 99.9999 NAMUR (DC) 000.000 999.999 TTL (DC) 0000.00 9999.99 Free of voltage 00000.0 99999.9 contact (DC) 000000 999999 BQ TF2 Pick-up (AC) 0.001% RDG 50 ppm/C 0.00000 9.99999 Voltage (AC) up to 3 digit 00.0000 99.9999 100VAC 000.000 999.999 Voltage (AC) up to 0000.00 9999.99 500VAC 00000.0 99999.9 000000 999999 (nn) The min indication is -9.99999, ..., -999999 in case of rotation speed detection function 2 Specifications are subject to change without notice UDM60 DS ENG 090112