Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF..... TM 4TH Generation TRIPLESHIELD Adjustable sensing distance: 2 - 20 mm flush or 4-30 mm non-flush Protection: short-circuit, transients and reverse polarity Dust and humidity compensation Dust or temperature alarm output Rated operational voltage: 10-40 VDC Output: DC 200 mA, NPN or PNP Standard Output: NO and NC LED indications for power-supply, output and stability IP67, IP68, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12 Cable and M12 connector versions available Product Description Ordering Key CA30CAN25NAM1 Capacitive proxim ity switch The CA30CA.. capacitive the green and yellow LEDs. Housing diameter (mm) proximity switches feature an The sensing distance is Housing material TH improved 4 generation TRI- increased by 20 25 % Housing length TM PLESHIELD technology. allowing room for additional Detection principle Furthermore, these sensors stable detection. Rated operating dist. (mm) feature increased immunity The dust alarm function Output type to electromagnetic interfer- gives an early warning that Output configuration ence (EMI), especially to fre- the sensing surroundings Connection type quency drives. Not only does have to be cleaned. TH 4 generation TRIPLESH- The temperature alarm func- TM IELD feature an increased tion raises an alarm if the EMI, but it also increases sensing surface goes beyond the immunity to humidity and 60 degree Celsius. dust. The implementation of The sensor housing is featur- stability indication eases the ing IP69K as well as approval setup procedure, as both by ECOLAB for cleaning and Stable ON and Stable OFF disinfection agents. positions are indicated by Type Selection Housing Sensor Output Output Connection Rated operating Ordering no. Ordering no. Ordering no. diameter type type function distance (S ) Standard Dust alarm Temperature alarm n M 30 Flush NPN NO+NC Cable 0 - 16 mm CA30CAF16NA M 30 Flush NPN NO+NC M12 Plug 0 - 16 mm CA30CAF16NAM1 M 30 Flush PNP NO+NC Cable 0 - 16 mm CA30CAF16PA M 30 Flush PNP NO+NC M12 Plug 0 - 16 mm CA30CAF16PAM1 1) 1) M 30 Flush PNP NO Cable 0 - 16 mm CA30CAF16PODU CA30CAF16POTA 1) 1) M 30 Flush PNP NC Cable 0 - 16 mm CA30CAF16PCDU CA30CAF16PCTA 2) M 30 Flush PNP NC M12 Plug 0 - 16 mm CA30CAF16PCM1DU M 30 Non-Flush NPN NO+NC Cable 0 - 25 mm CA30CAN25NA M 30 Non-Flush NPN NO+NC M12 Plug 0 - 25 mm CA30CAN25NAM1 M 30 Non-Flush PNP NO+NC Cable 0 - 25 mm CA30CAN25PA M 30 Non-Flush PNP NO+NC M12 Plug 0 - 25 mm CA30CAN25PAM1 3) 3) M 30 Non-Flush PNP NO Cable 0 - 25 mm CA30CAN25PODU CA30CAN25POTA 3) 3) M 30 Non-Flush PNP NC Cable 0 - 25 mm CA30CAN25PCDU CA30CAN25PCTA 1) Replaced by CA30CAF16BPA2IO 2) Replaced by CA30CAF16BPM1IO 3) Replaced by CA30CAN25BPA2IO Specifications EN 60947-5-2 Rated operating distance (S ) Flush mounted sensor 0 - 16 mm (factory setting n Non-flush mounted sensor 0 - 25 mm (factory setting 16 mm - non-flush mounted) 25 mm), (ref. target 48x48 mm ST37, (ref. target 75x75 mm ST37, 1 mm thick, grounded) 1 mm thick, grounded) Specifications are subject to change without notice (10.12.2020) 1 CA30CAN/CAF..... Specifications (cont.) EN 60947-5-2 Sensitivity control Adjustable by potentiometer Connection Electrical adjustment 11 turns Cable PVC, 2 Mechanical adjustment 16 turns 5.2 x 2 m, 4 x 0.34 mm Adjustable distance Oil proof, grey Flush types 2 to 20 mm Plug (M1) M12 x 1 - 4 pin Non-flush types 4 to 30 mm Temperature alarm output 60C 5C Effective operating dist. (S ) 0.9 x S S 1.1 x S Response time examples r n r n T = 25C 16 sec T = 800C A EXC Usable operating dist. (Su) 0.85 x Sr Su 1.15 x Sr 390 sec T = 80C EXC Repeat accuracy (R) 5% TM TRIPLESHIELD Hysteresis (H) 3 - 20% Exceeding the norms for Rated operational volt. (U ) 10 to 40 VDC (ripple incl.) B capacitive sensors Ripple 10% Electrostatic discharge (EN61000-4-2) Output function NPN or PNP Contact discharge > 40 kV Output switching function N.O. and N.C. Air discharge > 40 kV Rated operational current (Ie) 200 mA (continuous) Electrical fast transients/burst Capacitive load 100 nF (EN 61000-4-4) 4kV No-load supply current (I ) 12 mA o Surge Voltage drop (U ) 2.0 VDC 200 mA DC (EN 61000-4-5) d Power-supply > 2kV (with 500 ) Minimum operational Sensor output > 2kV (with 500 ) current (I ) 0.5 mA m Wire conducted disturbances OFF state current (I ) 100 A r (EN 61000-4-6) > 20 Vrms Protection Short-circuit, reverse Power-frequency magnetic polarity, transients fields (EN 61000-4-8) Frequency of operating Continuous > 60 A/m, 75.9 tesla cycles (f) 50 Hz Short-time > 600 A/m, 759 tesla Response time OFF-ON (t ) 10 ms on Radiated RF electromagnetic Response time ON-OFF (t ) 10 ms off fields (EN 61000-4-3) > 20 V/m Power ON delay (t ) 200 ms v Shock (IEC 60068-2-32) 30 G / 11ms, 3 pos, 3 neg per axis Indication Target detected LED, yellow Rough handling shocks Power and detection stability LED, green (IEC 60068-2-31) twice from 1 m 100 times from 0.5 m Environment Installation category III (IEC 60664, 60664A Vibration (IEC 60068-2-6) 10 to 150 Hz, 1 mm / 15 G 60947-1) Housing material Degree of pollution 3 (IEC 60664, 60664A Body PBT, grey, 60947-1) 30% glass reinforced Degree of protection IP 67, IP 68/60 min., IP69K* Cable gland PA12, black (IEC 60529 60943-1) Fingernuts PA12, black NEMA type 1, 2, 4, 4X, 5, 6, 6P, 12 Trimmershaft Nylon Operating temperature -30 to +85C ( -22 to +185F) Weight Max. temperature on sensing face 120C (248F) Cable version 190 g Storage temperature -40 to +85C (-40 to +185F) Plug version 106 g Rated insulation voltage 1 kVAC (rms) Approvals cULus (UL508), ECOLAB IEC protection class III CE-marking Yes Tightening torque 7.5 Nm MTTF 829 years 40C (+104F) d 90 * The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications. The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning. 60 The sensor is exposed to high-pressure water from a spray nozzle that is fed with 80C water at 8000 10000 KPa (80100bar) and a flow rate of 146L/min. The nozzle is held 100 150 mm from the sensor at angles of 0, 30, 60 and 90 for 30s each. The test device sits on a turntable that rotates with a speed of 5 30 times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear- ance and function. 0 2 Specifications are subject to change without notice (10.12.2020)