Energy Management Energy Analyzer Type EM24 DIN Class 1 (kWh) according to EN62053-21 Class B (kWh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy 0.5 RDG (current/voltage) Energy analyzer Instantaneous variables readout: 4 DGT Energies/gas/water readout: 7+1 DGT System variables: VLL, VLN, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence. Single phase variables: VLL, VLN, A, VA, W, var, PF Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs single phase measurements Gas, cold water, hot water, kWh remote heating measurements Hour counter (6+2 DGT) TRMS measurements of distorted sine waves (voltages/cur- rents) Self power supply (AV0-AV2-AV9 inputs) Auxiliary power supply (AV5-AV6 inputs) Application adaptable display and programming procedure 3 digital inputs for tariff selection, DMD synch or gas/ (Easyprog function) water (hot-cold) and remote heating metering (on request) Easy connections management 2 digital outputs for pulses or for alarms or as a mix of them Certified according to MID Directive (option PF only): (on request) see how to order below Dimensions: 4-DIN modules Other version available (not certified, option X and P): Protection degree (front): IP50 see how to order on the next page RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility Dupline communication capability (DP option) Product Description Three-phase energy analyzer for DIN-rail mounting with IP50 Moreover the meter can be pro- alarm outputs. In alternative the with built-in configuration joy- (front) protection degree. Direct vided with digital outputs that RS485 communication port and stick and LCD data displaying connection up to 65A and by can be either for pulse propor- 3 digital inputs or Dupline port particularly indicated for active means of external current and tional to the active and reactive and 3 digital inputs are avail- and reactive energy metering potential transformers. energy being measured or for able as an option. and for cost allocation. Housing How to order EM24 DIN AV5 3 X O2 PF Certified according to MID Directive, Model Annex + Annex or Annex B + MID Range code Annex F for legal metrology relevant to System active electrical energy meters (see Annex MI-003 of Power supply MID). Can be used for fiscal (legal) metrology. Inputs/Outputs Option Type Selection for MID version Range codes System Inputs/Outputs Power supply AV5: 400V AC - 5(10)A LL XX: none X: Self power supply 3: 3-phase, 4-wire (CT connection) O2: dual open collector (See Power supply balanced load AV2: V : 113V to 230V LN LN type (dual pulse or one specifications) V : 230V to 400V LL LL pulse + one alarm or D: 115/230VAC (50Hz) I: 10(65)A dual alarm) AV9: 400V AC - 10(65)A LL IS: 3 digital inputs for tariff (direct connection) selection or Gas/Water/ remote heating meter- ing plus RS485 port Options NOTE: please check the DP: Dupline port plus 3 dig- ital inputs for Gas/ availability of the needed PF: Certified according to MID Directive, Annex + Annex water/ remote heating code on the verification path or Annex B + Annex F for legal metrology relevant metering tables below before order . to active electrical energy meters (see Annex MI-003 of MID). Can be used for fiscal (legal) metrology. AV5 3 D XX AV9 3XPXXF O2 O2 PF IS IS AV2 3 DP X Specifications are subject to change without notice EM24 DIN DS 051110 1 Range System Power supply Input/Output Option Range System Power supply Input/Output OptionEM24 DIN How to order EM24 DIN AV5 3 X O2 X STANDARD Model Range code System Not certified according to MID directive. Cannot be Power supply used for fiscal (legal) metering. Inputs/Outputs Option Type Selection for standard version Range codes System Inputs/Outputs Power supply AV5: 400V AC - 1/5 (10)A LL 1: 1-phase, 2-wire XX: none X: Self power supply (CT connection) 3-phase, 3-wire, O2: dual open collector (See Power supply V : 160 V to 480V LN LN 3-phase, 4-wire type (dual pulse or one specifications) V : 277 V to 830V LL LL balanced load (*) pulse + one alarm or L: 18 to 60VAC/DC (48 to AV6: 208V AC - 1/5(10)A LL 3: balanced and dual alarm) 62Hz) (*) (VT/PT and CT unbalanced load: R2: dual relay type (func- D: 115/230 VAC (48 to connections) 3-phase, 4-wire tions as per O2) (*) 62Hz) V : 40V to 144V LN LN 3-phase, 3-wire XS: RS485 port (*) V : 70V to 250V LL LL 2-phase, 3-wire IS: 3 digital inputs for tariff AV0: 208V AC -10(65)A LL 1-phase, 2-wire selection or Gas/ (direct connection) (*) water/ remote heating Options V : 96V to 144V LN LN metering plus RS485 V : 166V to 250V LL LL port (*) on request. X: none AV2: 400V AC 10(65)A LL DP: Dupline port plus 3 dig- P: Bearing EC. Type (direct connection) (*) ital inputs for Gas / NOTE: please check the examination (annex B V : 113V to 265V LN LN water / remote heating of MID) relevant to V : 196V to 460V availability of the needed LL LL metering active electrical energy AV9: 400V AC - 10(65)A LL code on the verification path meters (see Annex MI- (direct connection tables below before order. 003). V : 184V to 276V LN LN V : 318V to 480V LL LL AV5 3 XX D P AV9 3 XX X P IS IS DP L XS X XS R2 XX R2 DP D L 1 XX XX 1 AV0 IS IS 3 DP DP XS XS R2 R2 AV6 1 XX D X AV2 3XX XP 3 XS L O2 IS IS DP DP R2 XS XX 1 XX O2 XS IS DP 2 Specifications are subject to change without notice EM24 DIN DS 051110 Range System Input/Output Power supply Option Range System Input/Output Power supply Option