Receiver for Digital Signals Du line Types G 3430 1149, G 3430 2249, G 3430 4443 Fieldbus Installationbus 1-, 2- or 4-channel receiver Galvanically separated SPDT or SPST relay outputs Load: 1 x 10 A/250 VAC 2 x 10 A/250 VAC 4 x 5 A/250 VAC H4-housing For mounting on DIN-rail (EN 50022) LED-indications for supply, outputs and Dupline carrier AC or DC power supply Channel coding by GAP 1605 (see the data sheet on GAP 1605 for details) Product Description Ordering Key G 3430 4443 024 Dupline receiver. VAC/10 A or SPST relay out- Type: Dupline SPDT relay outputs for con- puts for control of 4 loads of H4-housing trol of 1or 2 loads of up to 250 up to 250 VAC/5 A. Receiver No. of channels Output type Power supply Type Selection Supply Ordering no. Ordering no. Ordering no. 1 channel 2 channels 4 channels 10 A/250 VAC 10 A/250 VAC 5 A/250 VAC 24 VAC G 3430 1149 024 G 3430 2249 024 G 3430 4443 024 115 VAC G 3430 1149 115 G 3430 2249 115 G 3430 4443 115 230 VAC G 3430 1149 230 G 3430 2249 230 G 3430 4443 230 10 to 30 VDC G 3430 1149 800 15 to 30 VDC G 3430 2249 824 G 3430 4443 824 Output Specifications G 3430 1149 ... G 3430 2249 ... G 3430 4443 ... (1 channel) (2 channels) (4 channels) Outputs 1 SPDT relay 2 SPDT relays 4 SPST relays Isolated in groups of 1 x 1 2 x 1 4 x 1 Contact ratings (AgCdO) (micro gap) (micro gap) (micro gap) Resistive loads AC 1 10 A/250 VAC (2500 VA) 10 A/250 VAC (2500 VA) 5 A/250 VAC (1250 VA) DC 1 1 A/250 VDC (250 W) 1 A/250 VDC (250 W) 0.25 A/250 VDC (62 W) or 10 A/25 VDC (250 W) 10 A/25 VDC (250 W) 5 A/25 VDC (125 W) Inductive loads AC 15 2.5 A/230 VAC 2.5 A/230 VAC 2.5 A/230 VAC DC 13 5 A/24 VDC 5 A/24 VDC 5 A/24 VDC 6 6 6 Mechanical lifetime 30 x 10 operations 30 x 10 operations 30 x 10 operations Electrical lifetime 5 5 6 (at max load) AC 1 2.5 x 10 operations 2.5 x 10 operations 2.0 x 10 operations Operating frequency 7200 operations/h 7200 operations/h 7200 operations/h Dielectric voltage Outputs - Dupline 4 kVAC (rms) 4 kVAC (rms) 4 kVAC (rms) Response time 1 pulse train 1 pulse train 1 pulse train Specifications are subject to change without notice (28.09.99) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupG 3430 1149, G 3430 2249, G 3430 4443 Du line Fieldbus Installationbus Supply Specifications Power supply Overvoltage cat. III (IEC 60664) Power supply DC types Overvoltage cat. III (IEC 60664) Rated operational voltage Operational voltage through term. 21 & 22 230 230 VAC 15% (IEC 60038) through term. 21 & 22 800 10 to 30 VDC (ripple included) 115 115 VAC 15% (IEC 60038) 824 15 to 30 VDC (ripple included) 024 24 VAC 15% Ripple 3 V Frequency 45 to 65 Hz Reverse-polarity protection Yes Voltage interruption 40 ms Rated operational current Rated operational power G 3430 1149 800 150 mA G 3430 1149 024/115/230 Typ. 3.5 VA G 3430 2249 824 150 mA G 3430 2249 024/115/230 Typ. 4.5 VA G 3430 4443 824 100 mA G 3430 4443 024/115/230 Typ. 3.5 VA Power dissipation Power dissipation G 3430 1149 800 5.5 W G 3430 1149 024/115/230 6.5 W G 3430 2249 824 5.5 W G 3430 2249 024/115/230 8 W G 3430 4443 824 6 W G 3430 4443 024/115/230 8 W Inrush current 1 A Rated impulse withstand Rated impulse withstand voltage 2304 kV voltage 800 V 115 2.5 kV Dielectric voltage 024 800 V Supply - Dupline 200 VAC (rms) Dielectric voltage Supply - Outputs 4 kVAC (rms) Supply - Dupline 4 kVAC (rms) Supply - Outputs 4 kVAC (rms) Mode of Operation General Specifications 1-channel receiver with When a transmitter coded to Output OFF delay change-over contact output the selected channel is ac- Upon loss of Dupline carrier 20 ms tivated, the output turns on Power ON delay Typ. 2 s The output is coded by and remains on until the re- Power OFF delay 1 s means of the code program- spective channel becomes Indication for mer GAP 1605. deactivated. The default set- Supply ON LED, green ting of the module is such Output ON LED, red (one per output) The output is normally OFF. that upon loss of Dupline Dupline carrier LED, yellow When a transmitter coded to carrier all outputs go off. the selected channel is acti- Environment vated, the output turns on 4-channel receiver with Degree of protection IP 20 and remains on until the four normally open contact Pollution degree 3 (IEC 60664) respective channel becomes outputs Operating temperature -20 to +50C (-4 to +122F) deactivated. The default set- Storage temperature -50 to +85C (-58 to +185F) ting is such that upon loss of Each output may be coded Humidity (non-condensing) 20 to 80% Dupline carrier the output individually by means of the Mechanical resistance goes off. code programmer GAP 1605. Shock 15 G (11 ms) The default setting of the Vibration 2 G (6 to 55 Hz) 2-channel receiver with two module is such that upon change-over contact out- loss of Dupline carrier all Dimensions puts outputs go off. Material (see Technical informations) H4-housing Each output may be coded For changing the default set- Weight individually by means of the ting, please refer to the data- G 3430 1149, G 3430 2249 250 g code programmer GAP 1605. sheet on GAP 1605. G 3430 4443 300 g The outputs are normally off. Operation Diagram Power supply Dupline carrier Transmission on channel 1 Output 1 Transmission on channel 2 Output 2 2 Specifications are subject to change without notice (30.04.03) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group