Universal Analog Output Module for Du line DIN-Signals Fieldbus Installationbus Type G 3439 6470 4 analog outputs Outputs individually configurable for 0-20 mA, 4-20 mA or 0-10 VDC Selectable resolution: 1/1999 or 1/255 of full scale Selectable dataformat : 8-bit, AnaLink or 3 1/2 digit BCD EMC immunity according to EN50082-2 (industrial envi- ronment) DIN-rail mounting (EN 50022) Address-selection through rotary switches LED-indication for supply and Dupline carrier LED-indication for invalid switch setting and faulty received data Watchdog output for faulty received data H4 housing Product De scrip tion Ordering Key G 3439 6470 024 Dupline 4 output universal the same module possib le. Type: Dupline analog output module with The transmission format on H4-housing internal supply. The module Dupline can be selected to Receiver receives signals on a digital fit the output module into No. of channels format from Dupline and existing installations, or simp - Output type converts them to analog out- ly to use the most suitable Power supply puts. The output type can be combination of resolution, selected as 0-20 mA, 4-20 signalling capacity and speed. mA or 0-10 VDC for each The formats are: 8-bit binary, output individually making a AnaLink and 3 1/2 digit BCD mix of analog output types on (with or without multiplexing). Type Selection Supply Ordering no. 24 VAC G 3439 6470 024 115 VAC G 3439 6470 115 230 VAC G 3439 6470 230 10-30 VDC G 3439 6470 800 Output Spec i fi ca tions Outputs set to voltage Outputs set to current Signal Signal output DIN-voltage output DIN-current output Signal range 0-10 VDC 0-20 mA / 4-20 mA Output load 100 k 0-450 Short circuit protection Yes Yes Watchdog output 30 V 50 mA Resolution A/D 11 bits or 8 bits 11 bits or 8 bits Transmission 1/1999 or 1/255 1/1999 or 1/255 Output settling time 0.5 sec. 0.5 sec Inaccuracy (11-bit) (ref. temp. 25C) < 0.4% of full-scale < 0.4% of full-scale < 0.2% of reading < 0.2% of reading < 1 count < 1 count Temperature influence (ref. temp. 25C) < 15 ppm/K of full-scale < 15 ppm/K of full-scale < 150 ppm/K of reading < 150 ppm/K of reading Recommended cable length < 25 m < 25 m Dielectric voltage Output - Dupline 250 VAC (rms) 250 VAC (rms) Output - Watchdog output 2 kVAC (rms) 2 kVAC (rms) Specifications are subject to change without notice (22.01.2007) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupG 3439 6470 DDuu linlinee FieldbusFieldbus InstallationbusInstallationbus Supply Spec i fi ca tions General Spec i fi ca tions Power supply AC-types Overvoltage cat. lll (IEC 60664) Power ON delay 2 s Operational voltage Indication for through term. 21 & 22 230 230 VAC, -10/+15 % (IEC 60038) Supply ON LED, green 115 115 VAC, -10/+15 % (IEC 60038) Dupline carrier LED, yellow 024 24 VAC, -10/+15 % Dupline format error LED, red Frequency 45 to 65 Hz Illegal switch setting LED, red - flashing Power consumption typ. 7 VA Environment Power dissipation 8 W Degree of protection IP 20 Rated impulse withstand voltage 230 4 kV Pollution degree 3 (IEC 60664) 115 2.5 kV Operating temperature 0 to +50C (+32 to +122F) 024 800 V Storage temperature -20 to +85C (-4 to +185F) Dielectric Voltage Humidity (non-condensing) 20 to 80% Supply - Dupline 4 kVAC (rms) Mechanical resistance Supply - Signal output 4 kVAC (rms) Shock 15 G (11 ms) Supply - Watchdog output 4 kVAC (rms) Vibration 2 G (6 to 55 Hz) Power supply DC-types Dimensions Operational voltage Material through term. 21 & 22 800 10,5 V - 30 VDC (Ripple incl.) (see Technical information) H4-Housing Ripple < 3 V Reverse polarity protection Yes Weight 300 g Power consumption < 4 W CE-marking Yes Power dissipation < 6 W Rated impulse withstand voltage 800 V Dielectric Voltage Supply - Dupline 500 VAC (rms) Supply - Signal output 250 VAC (rms) Supply - Watchdog output 2 kVAC (rms) Switch Settings Rotary switches in the front Shunt-switches on system top A-P 0-F Mode 3 1/2 digit: Channel group-pair Mux. address for output 1, Ex. setting: rest of the outputs (if enabled) C or D = C-D on the following addresses ON ON ON ON 8-bit: Channel group Same as 3 1/2 digit. Ex. setting 5 (with 2 outputs enabled) = 1 2 1 2 1 2 1 2 Output 1 on mux address 5 Output 2 on mux address 6 Current shunts on output 1-4: Analink: Channel group Channel no. for output 1, rest of ON/ON = 0-10 V / (2-10 V) the outputs (if enabled) on the OFF/OFF = 0-20 mA / 4-20 mA following channels. Setting of 0+9-F is not valid. Function switches in the front ON 1 2 34 5 6 7 8 9 10 Offset on output 1-4 ON = 4-20 mA / (2-10 V) OFF = 0-20 mA / 0-10 V No. of enabled outputs OFF ON : 1 ON OFF: 2 ON ON : 3 OFF OFF : 4 Mode (Format) OFF OFF : Analink OFF ON : 8-bit binary ON OFF : 3 1/2 digit BCD ON ON : Reserved for future use Multiplex ON/OFF (Only used in 3 1/2 digit BCD and 8-bit binary mode) ON = Data is multiplexed OFF = Data to output 1 is received on the group (or grouppair) rotarysw. A-P is set to, data from input 2, 3, 4 (if enabled) on the following groups (or grouppairs) Maintain ON/OFF ON = Keep output in case of Dupline (or format) error OFF = Zero output in case of Dupline (or format) error 2 Specifications are subject to change without notice (22.01.2007) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group