DuplineSafe Safety Relay Output Module Type GS 3830 0143 Safety relay that monitors up to 63 Safety Input Modules Safety output available on 2 separate relay outputs (NO) Safety approved according to IEC/EN 61508-SIL3, IEC/EN 62061-SIL3 and ISO/EN 13849-1 PL e Approval authority: TV Rheinland Group cULus approved Automatic or manual restart Status output for external equipment (e.g. PLC) Operates on a standard Dupline network It is possible to use DuplineSafe modules and standard Dupline modules on the same bus H8-housing For mounting on DIN-rail (EN 50022) LED-indication for supply, relay status, manual restart ready and Dupline carrier AC power supply Configuration with GS73800080 Product Description Ordering Key GS 3830 DuplineSafe relay output itored. The module can be DuplineSafe module approved according configured to operate with H8-Housing to IEC/EN 61508-SIL3, IEC/ automatic or manual restart Output module EN 62061-SIL3 and ISO/EN after the safety relays have 13849-1 PL e by TV. The been released. A non-safe module monitors up to 63 status output is available DuplineSafe input modules, for connection to external Type Selection type number GS751021xx. equipment, e.g. a PLC. The The NO relay contacts are Module must be configured Supply Ordering no. only in the closed position if prior to installation by means DuplineSafe Safety Input Module a valid safe state signal is of the DuplineSafe configur- received from all the Safety ation unit GS73800080. 230 VAC GS 3830 0143 230 Input modules being mon- Output Specifications General Specifications Power ON delay < 10 s Safety output 2 x NO Relay Contact type Forced contact Environment Contact material Ag-alloy, gold plated Degree of protection IP 20 Switching voltage 250 VAC/VDC Pollution degree 3 (IEC 60664) Switching capacity 6 A AC-1 at 230 V Operating temperature -25C to 50C 3 A AC-15 at 230V Storage temperature -30C to 70C 5 A DC-13 at 24V Humidity (non-condensing) 20 to 80% Mechanical resistance Response time 1 max 300ms Shock 15 G (11 ms) From input contact of safety Vibration 2 G (6 to 55 Hz) input module opens to safety relay releases Terminals Screwterminals Response time 2 max 600 ms Tightening torque 0.8 Nm From input contact of safety Housing input module closes Dimensions H8-housing (144 x 77 x 70 mm) to safety relay activates Mounting DIN-rail Status output 1 NPN transistor Approvals IEC/EN 61508-SIL3 Output ON when fault IEC/EN 62061-SIL3 detected ISO/EN13849-1 PL e Safety approved No TV Rheinland Group Voltage < 30 VDC cULus Current < 50 mA Voltage drop < 2 V Note: The GS38300143 must be de-energized (power off) Short-circuit protection No before programming til module Isolation Output-Dupline 4 kVAC Safety Specifications Supply Specifications Standards Power Supply 230 VAC +/- 15% SFF 97% 115 VAC +/- 15% -6 PFD (T1 = 1 year) 5.5 x 10 Frequency 45 to 65 Hz -9 PFH 9.3 x 10 /h Power consumption 4 VA Power dissipation 3 W Specifications are subject to change without notice (14.12.2015) 1 GS 3830 0143 Indicators Wiring Diagram Supply OK LED, green Dupline OK LED, yellow Relay status LED, red Manual restart ready LED, red STATUS OUTPUT Configuration mode LEDs, all flashing RESTART DUPLINE 50 mA D+ 30 V D - + 19213141516171810 1 2 3 4 5 6 Input Specifications Manual restart 1 NO Contact 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Open loop voltage 5 V 115V 115V P NNP Short-circuit current 100 A SUPPLY Contact resistance < 1 k Cable length max. 2 m Dielectric voltage Inputs Dupline None Caution: Modules can be damaged by static electrical discharge. Before handling any modules, Electrostat- ic Discharge (ESD) protection must always be used. Mode of Operation The Safety Output module be open, thus keeping the Any type of Dupline Chan- note that all Dupline chan- GS38300143 monitors up system in a safe state. Find nel Generator can be used, nel addresses used for Safe- to 63 Safety Input modules, below a principle diagram of as this component is not ty Input modules must be type number GS751021xx. a DuplineSafe system. part of the safety function. monostable. Split I/O mode Each Safety Input module However, it is important to and intelligent channel func- The Channel Generator is monitoring the status of tions are not allowed. If this one potential-free contact rule is not obeyed, the relay Safety in a safety device, e.g. an contacts of the Safety Out- Output emergency stop palm but- put module will remain in the module ton or pull cord switch. The open position in any situa- Safety Input modules are tion. Safety continuously transmitting on Input the Dupline bus the status module Contactor 1 Combined Systems of the safety contacts using It is allowed to use stan- a dynamic signaling princi- dard Dupline modules on ple on two Dupline channel Tx 0 VDC the channel addresses not addresses (please refer to 24 VDC used for safety signals, thus GS751021xx datasheet for allowing combined systems. more details). Tx During configuration of the Contactor 2 Safety Output module, the Monitoring from a PLC, PC user must define on which or Text Display Tx Dupline channel address- 0 VDC There are two products es Safety Input modules 24 VDC available for interfacing shall be monitored. If all the a DuplineSafe system to a Tx configured Safety Input PLC, PC, Text Display or modules are sending a Touchscreen. One possi- RS 232 / valid safe-state signal, RS 485 bility is the Profibus-DP Channel PLC / then the relay contacts of gateway (GS38910125), Generator Controller the Safety Output module the other possibility is will be closed. In any other the small Modbus inter- situation (non-safe signal face GSTI50 for Text dis- received from one or more plays and Touchscreens. DuplineSafe Principle Diagram Safety Input modules or bus Using these products, it fault), the relay contacts will is possible to monitor the 2 Specifications are subject to change without notice (14.12.2015)