Proximity Inductive Sensors Extended range, Nickel-Plated Brass Housing Types ICB, M30 Sensing distance: 15 to 22 mm Flush and non-flush types Short and long body versions Rated operational voltage (U ): 10 - 36 VDC b Output: DC 200 mA, NPN or PNP Normally open, Normally closed LED indication for output ON Protection: reverse polarity, short circuit, transients Cable and M12 plug versions According to IEC 60947-5-2 CSA certified for Hazardous Locations Product Description Ordering Key ICB30SF15NOM1 Type A family of inductive proxim- high sensing range is Housing style ity switches in industrial requested. Housing material standard nickel-plated brass Output is open collector Housing size housings. They are able to NPN or PNP transistors. Housing length handle applications where Detection principle Sensing distance Output type Output configuration Connection Type Selection Connec- Body Rated Ordering no. Ordering no. Ordering no. Ordering no. tion style operating NPN PNP NPN PNP distance S Normally open Normally open Normally closed Normally closed n 1) Cable Short 15 mm ICB 30 SF 15 NO ICB 30 SF 15 PO ICB 30 SF 15 NC ICB 30 SF 15 PC 2) Cable Short 22 mm ICB 30 SN 22 NO ICB 30 SN 22 PO ICB 30 SN 22 NC ICB 30 SN 22 PC 1) Plug Short 15 mm ICB 30 SF 15 NOM1 ICB 30 SF 15 POM1 ICB 30 SF 15 NCM1 ICB 30 SF 15 PCM1 2) Plug Short 22 mm ICB 30 SN 22 NOM1 ICB 30 SN 22 POM1 ICB 30 SN 22 NCM1 ICB 30 SN 22 PCM1 1) Cable Long 15 mm ICB 30 LF 15 NO ICB 30 LF 15 PO ICB 30 LF 15 NC ICB 30 LF 15 PC 2) Cable Long 22 mm ICB 30 LN 22 NO ICB 30 LN 22 PO ICB 30 LN 22 NC ICB 30 LN 22 PC 1) Plug Long 15 mm ICB 30 LF 15 NOM1 ICB 30 LF 15 POM1 ICB 30 LF 15 NCM1 ICB 30 LF 15 PCM1 2) Plug Long 22 mm ICB 30 LN 22 NOM1 ICB 30 LN 22 POM1 ICB 30 LN 22 NCM1 ICB 30 LN 22 PCM1 1) 2) For flush mounting in metal For non-flush mounting in metal Specifications Rated operational voltage (U ) 10 to 36 VDC (ripple incl.) Indication for short circuit/ b overload LED blinking Ripple 10% Assured operating Output current (I ) 200 mA 50C e sensing distance (S ) 0 S 0.81 x S a a n ( 150 mA 50-70C) Effective operating OFF-state current (I ) 50 A r distance (S) 0.9 x S S 1.1 x S r n r n No load supply current (I ) 15 mA O Usable operating distance (S ) 0.85 x S S 1.1 x S u r u r Voltage drop (U) Max. 2.5 VDC 200 mA d Repeat accuracy (R) 5% Protection Reverse polarity, Differential travel (H) short-circuit, transients (Hysteresis) 1 to 20% of sensing dist. Dielectric impulse voltage Ambient temperature withstand 1 kV/0.5 J Operating -25 to +70C (-13 to +158F) Power ON delay (t) 300 ms v Storage -30 to +80C (-22 to +176F) Operating frequency (f) 1000 Hz Shock and vibration IEC 60947-5-2/7.4 Indication for output ON Activated LED, yellow Housing material NO version Target present Body Nickel-plated brass NC version Target not present Front Grey thermoplastic polyester Specifications are subject to change without notice (21.01.13) 1ICB, M30 Specifications (cont.) Connection Approvals (cont.) 2 Cable 2 m, 3 x 0.3 mm , CCSAUS As Process Control grey PVC, oil proof Equipment for Hazardous Plug M12 x 1 Locations. - Class I, Division 2, Degree of protection IP 67 Groups A, B, C and D. Weight (cable/nuts included) - Class I, Zone 1, AEx/Ex d ICB30 S Max. 185 g IIB+H2, T5, Enclosure Type 4. ICB30 L Max. 195 g Ambient temperature Dimensions See diagrams below Ta: -25 to +60C. Note: AEx for USA, Tightening torque 25 Nm Ex for Canada Approvals CE-marking Yes UL (RU), CSA: As Industrial Control Equipment - Proximity EMC protection According to IEC 60947-5-2 Switches. IEC 61000-4-2 (ESD) 8 KV air discharge, Types 1, 4, 4X or 12. 4 KV contact discharge Max ambient temperature IEC 61000-4-3 3 V/m 40C. IEC 61000-4-4 2 kV IEC 61000-4-6 3 V IEC 61000-4-8 30 A/m Dimensions 59 71 LED LED 30 10,6 12 30 10,6 Short body, flush version, cable Short body, non-flush version, cable 55 67 14 14 23 23 LED LED 9,8 30 12 30 9,8 Short body, flush version, plug Short body, non-flush version, plug 79 91 LED LED 10,6 12 50 10,6 50 Long body, flush version, cable Long body, non-flush version, cable 2 Specifications are subject to change without notice (21.01.13)