ICS, IP69K, M18 Proximity Inductive Sensors - Ecolab certified Standard and Extended Range, Stainless Steel Housing Types ICS, IP69K, M18 Sensing distance: 5 to 12 mm Flush or non-flush mountable Long body version Rated operational voltage (U b): 10 - 36 VDC Output: DC 200 mA, NPN or PNP Normally open or normally closed 4 x 90 LED indication for output ON, short-circuit and overload Protection: reverse polarity, short circuit, transients M12 plug version According to IEC 60947-5-2 High-pressure washdown resistant Ecolab certified, FDA-certified plastic Laser engraved on the housing, permanently legible Extended temperature range: -40C...+80C CSA certified for Hazardous Locations Product Description Ordering Key ICS18LF05NOM1-FB A family of inductive proxim- They are fully sealed and Type ity switches in stainless steel resistant to all common Housing style (AISI 316L) ideal for food acid and alkaline cleaning Housing material and beverage applications agents and disinfectants Housing size where sensors are exposed (Ecolab certified). IP68 and Housing length to high pressure and high IP69K-rated products. Out- Detection principle temperature cleaning pro- put is open collector NPN or Sensing distance cesses. PNP transistors. Output type Output configuration Connection Washdown series Type Selection Connec- Body Rated Ordering no. Ordering no. Ordering no. Ordering no. tion style operating NPN, PNP, NPN, PNP, distance S Normally open Normally open Normally closed Normally closed n Standard range 1) Plug Long 5 mm ICS18LF05NOM1-FB ICS18LF05POM1-FB ICS18LF05NCM1-FB ICS18LF05PCM1-FB 2) Plug Long 8 mm ICS18LN08NOM1-FB ICS18LN08POM1-FB ICS18LN08NCM1-FB ICS18LN08PCM1-FB Extended range 1) Plug Long 8 mm ICS18LF08NOM1-FB ICS18LF08POM1-FB ICS18LF08NCM1-FB ICS18LF08PCM1-FB 2) Plug Long 12 mm ICS18LN12NOM1-FB ICS18LN12POM1-FB ICS18LN12NCM1-FB ICS18LN12PCM1-FB 1) 2) For flush mounting in metal For non-flush mounting in metal Specifications Rated operational voltage (U ) 10 to 36 VDC (ripple incl.) Indication for output ON Activated LED, yellow (4x90) b NO version Target present Ripple 10% NC version Target not present Output current (I ) 200 mA 50C e Indication for short circuit/ ( 150 mA 50-80C) overload LED blinking (f = 2 Hz) OFF-state current (I ) 10 A r Assured operating No load supply current (I ) 15 mA o sensing distance (S ) 0 S 0.81 x S a a n Voltage drop (U ) Max. 2 VDC 200 mA d Effective operating Protection Reverse polarity, distance (S ) 0.9 x S S 1.1 x S r n r n short-circuit, transients Usable operating distance (S ) 0.9 x S S 1.1 x S u r u r Voltage transient 1 kV/0.5 J Repeat accuracy (R) 5% Power ON delay (t ) 20 ms v Differential travel (H) Operating frequency (f) 1500 Hz (Hysteresis) 1 to 20% of sensing dist. Specifications are subject to change without notice (10.01.2017) 1ICS, IP69K, M18 Specifications (cont.) Ambient temperature Approvals c ULsu (UL508) Operating -40 to +80C (-40 to +176F) c CSAus As Process Control short exposure (15) to Equipment for Hazardous 100C during cleaning Note: The terminal connector Locations. process (version ...M1) was not - Class I, Division 2, Storage -40 to +80C (-40 to +176F) evaluated. The suitability of Groups A, B, C and D. Shock and vibration IEC 60947-5-2/7.4 the terminal connector should - T5, Enclosure Type 4. Housing material be determined in the end-use Ambient temperature Body Stainless steel (AISI 316L) application. Ta: -25 to +60C Front Grey PPS - FDA-certified CCC is not required for Connection products with a maximum Plug M12 x 1 operating voltage of 36 V Degree of protection IP67, IP68 (1 m, 7 days), EMC protection According to IEC 60947-5-2 IP69K IEC 61000-4-2 (ESD) 8 KV air discharge, 4 KV contact discharge Weight (cable/nuts included) Max. 70 g IEC 61000-4-3 3 V/m Dimensions See diagrams below IEC 61000-4-4 2 kV Tightening torque 25 Nm IEC 61000-4-6 3 V IEC 61000-4-8 30 A/m MTTF 850 years 50C (122F) d Dimensions (mm) 63 63 35 15 13 8 27 15 13 4 3 4 3 1 2 1 2 LED (4 x 90) LED (4 x 90) Flush version Non-flush version Installation Flush mountable proximity switches, when installed in Non-flush mountable proximity switches, when installed in damping material, must be according to Picture 1A. damping material, must be according to Picture 1B. Picture 1A Picture 1B Free zone or Free zone or 3 x d 3 x S 3 x S n non-damping n non-damping d d material material S : nominal sensing distance S : nominal sensing distance ** 12 mm, S = 8 mm (1x) n n n d : sensor diameter (18 mm) d : sensor diameter (18 mm) 16 mm, S = 12 mm (2x) n 2 Specifications are subject to change without notice (10.01.2017) **