Level Magnetic Sensors
ILMPU, ILU and ILMU Series
Non toxic polypropylene or plastic body
NO, NC or Change-over output function
Horizontal mounting
PVC or silicone cable output connection
Product Description Ordering Key
ILU.S.2/S1
The ILU and ILMPU models, used both as a NO function Type
for horizontal mounting, are and NC function depending Reed Contact Type
also made in non-toxic on mounting direction. Special Version
polypropylene. The ILMU models, also for
The ILMPU model, extremely horizontal mounting, is made
small dimensioned, can be in plastic material.
Type Selection
Diametro Galleggiante Output function Operating temperature Reference
17,5 mm NO, NC -20 +80 C ILMPU.5
31 mm ILMU.5
45 mm NO, Change-over -25 +100 C ILU.2
ILU.8
ILU.S.2
ILU.S.2/S1
General specification
Min liquid specific gravity
3
ILMPU ILMU 0,7 kg/dm
3
ILU 0,75 kg/dm
Max pressure
2
ILMPU ILMU 2 kg/cm
2
ILU 100 kg/cm
Case Plastic
Protection degree IP68
Output connection Silicone Cable
Electrical specifications
Contacts 2 5 8 S.2
Max switching voltage 250 Vac 240 Vac / 200 Vdc 1500 Vac 220 Vac
Max switching current 3 A 0,5 A 3 A 1 A
Max switching power 100 VA 50 VA 120 VA 60 VA
Specifications are subject to change without notice (20.08.01) 1Level Magnetic Sensors - ILMPU, ILU and ILMU Series
Dimensions
Wiring Diagrams
2 Specifications are subject to change without notice (20.08.01)