Photoelectrics
Retro-reflective
Type PA18CLR30T, AC, PBTP housing
Range: 3 m
Modulated infrared light
Supply voltage: 20 to 250 VAC
Output: 500 mA SCR
Make and break switching functions
LED output indication
High immunity to ambient light
Cable and plug versions
Ordering Key
Product Description
PA18CLR30TOM6
Type
The PA18CLR.. is a family of sensor provides adequate
Housing style
inexpensive general purpose sensing performance. The
Housing size
Retro-reflective sensors in sensors are simple to use
Housing material
industrial standard 18 mm and no adjustment are nec-
Housing length
cylindrical PBTP housing. essary. The output is a 2-
Detection principle
They are useful for simple wire NO or NC thyristor
Sensing distance
applications where a basic (SCR) output.
Output type
Output configuration
Connection type
Type Selection
Housing Rated Ordering no. Ordering no. Ordering no. Ord eri ng no.
diameter operating SCR/Cable SCR/Plug SCR/Cable SCR/Plug
dist. (Sn) Make switching Make switching Break switching Break switching
M18 3 m PA18CLR30TO PA18CLR30TOM6 PA18CLR30TC PA18CLR30TCM6
Note: Plugs and reflectors to be ordered separately
Specifications
Rated operating dist. (S ) Up to 3 m Operating frequency (f) Max. 20 Hz, light/dark ratio 1:2
n
Ref. reflector type ER4,
Response time
84 mm
OFF-ON (t ) 20 ms
ON
Temperature drift 0.4%/K ON-OFF (t ) 30 ms
OFF
Hysteresis (H) Power ON delay (t ) Typ. 100 ms
v
(Differential travel) 3 to 20%
Indication function Dark (NC) or light (NO) switching
Rated operational volt. (U ) 20 to 250 VAC, Output ON LED, yellow
B
45 to 65 Hz
Environment
Output current (AC 12, AC 140) Overvoltage category III (IEC 60664/60664A; 60947-1)
Continuous (I ) 500 mA Pollution degree 3 (IEC 60664/60664A; 60947-1)
e
Short-time (I) 3 A, max. 20 ms Degree of protection IP 67 (IEC 60529; 60947-1)
Min. operational current (I ) 10 mA Temperature
m
Operating -20 to +60C (-4 to 140F)
OFF-state current (I ) < 5 mA, typ. 2.6 mA
r
Storage -30 to + 70C (-22 to 158F)
Voltage drop (U ) 10 VAC, typ. 7 VAC
d
Vibration 10 to 150 Hz, 0.5 mm/-
Protection Transients
7.5 g (IEC 60068-2-6)
Transient voltage 1 kV/0.5 J
Shock 2 x 1 m 100 x 0.5 m
Light source GaAlAs LED, 880 nm
(IEC 60068-2-32)
Light type Infrared, modulated
Dielectric voltage 1600 V (IEC 60364-4-41)
Optical angle 2.2
Light spot size 150 mm at 2 m
Ambient light Max. 10,000 lux
Specifications are subject to change without notice (05.05.2008) 1(inch)
PA18CLR30T
Specifications (cont.) Dimensions
Housing material
Body PBTP grey thermoplastic
polyester
Front Luran , black
Cable end Polyester, black
Nuts Reinforced nylon
Connection
2
Cable Grey, 2 m, 2 x 0.5 mm ,
oilproof PVC
Plug M12 x 1
Cables for plug (M6) CON.6A-.. serie
Weight
Cable version 105 g
Plug version 22 g
Approvals UL, CSA
CE-marking Yes
M12 x 1
Operation Di a gram
Power supply
Object present, light beam in ter rupt ed
Tv
Output ON: Break switchi ng (NC)
Tv
Make switching (NO)
Wiring Diagrams Detection Diagram
Sensor
2 BN
Y
(feet)
X
ER4
Reflector
11.5 13
1.6 3.3 4.9 6.6 8.2 9.8
0.8
60.0
30.0 0.4
3 BU
0
0.0
2 BN
-30.0 -0.4
-60.0 -0.8
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
3 BU
Distance (m)
2 Specifications are subject to change without notice (05.05.2008)
(mm)