Photoelectrics Through-beam, Transistor Output Type PB18CNT15.. Safety Edge sensor for doors Range 15 m ESPE, PSPE type 2, PL C Modulated, infrared light Supply voltage: 10 to 30 VDC Output: 100 mA, NPN or PNP type Make or break switching Protection: reverse polarity, short circuit, transients Cable versions with or without connector Emitter mute and power adjustment CE, UL325 and UL508 approved Product Description Ordering Key PB18CNT15NO-C2 Type The PB18CNT. is a through lips to prevent water from Housing style beam sensor set specific entering the profile. Housing size designed for safety edge The emitter has a mute input Housing material sensing in industrial auto- to turn it off for evaluation of Sensor code matic doors. the sensor function. Detection principle The housing is designed to Available in 10-30 VDC Sensing distance fit a 18 mm rubber profile version. Output type and has integreted sealing Output configuration Cable connector Type Selection Housing Range Con- Ordering no. Ordering no. Ordering no. Ordering no. Ordering no. diameter S nec- Receiver Receiver Receiver Receiver Emitter n tor NPN, NO NPN, NC PNP, NO PNP, NC 18 mm 15 m NO PB18CNT15NO PB18CNT15NC PB18CNT15PO PB18CNT15PC PB18CNT15 18 mm 15 m YES PB18CNT15NO-C2 PB18CNT15NC-C2 PB18CNT15PO-C2 PB18CNT15PC-C2 PB18CNT15-C2 Note: Please order emitter and receiver separately Specifications Emitter Rated operational volt. (U ) 10 to 30 VDC Light type Infrared, modulated B Ripple (U ) 10% Light spot 940 mm 9 m rrp Supply current 20 mA Emitter angle 3 9 m Protection Reverse polarity, transients Power adjustment R ~ 3 k -10 k 3 m ... 18 m in 19 step x Power ON delay (t ) 100 ms v Control input Normal operation > 1.5 VDC Mute < 1.2 VDC Light source LED, 890 nm Specifications are subject to change without notice. Rev. *1* (17.02.2016) 1 PB18 Specifications Receiver Rated operating dist. (Sn) 15 m Utility category DC12 Control of resistive loads and solid state loads with Blind zone None optical isolation Temperature drift 0.4 %/C DC13 Control of electromagnets Hysteresis (H) 3 - 20 % Ambient light Rated operational volt. (U ) 10 to 30 VDC (ripple included) B 3,000 ... 3,200 K > 80,000 LUX (EN60947-5-2) Ripple (U ) 10 % rrp Detection angle 2.5 9 m No load supply current (I ) 16 mA o Operating frequency (f) 100 Hz Output current Response time OFF-ON (t ) 6.5 ms ON Continuous (I ) 100 mA e ON-OFF (t ) 3.5 ms OFF Short-time (I) 100 mA, Power ON delay (t ) 100 ms v (max. load capacity 100 nF) Output function Minimum operational current (I ) 0.5 mA m NPN or PNP Make or break (NO or NC) OFF-state current (I ) 100 A r Voltage drop (U ) 1.6 VDC 100 mA d Protection Short-circuit, reverse pola- rity, transients General Specifications Surge (EN 61000-4-5) Environment Overvoltage category IIl (IEC 60664/60664A, Power-supply > 1 kV (with 500 ) 60947-1) Sensor output > 1 kV (with 500 ) Pollution degree 3 (IEC 60664/60664A, Wire conducted disturbances 60947-1) (EN 61000-4-6) > 10 Vrms Degree of protection IP67 (IEC 60529 EN60947-1) Power-frequency magnetic 1, 2, 12 (NEMA types) fields (EN 61000-4-8) Temperature Continous > 30 A/m, 38 tesla Operating -20 to +50C (-4 to +122F) Short-time > 300 A/m, 380 tesla Storage -25 to +80C (-13 to +176F) Vibration (IEC 60068-2-6) 10 to 150 Hz, 1 mm / 15 g Rated insulation voltage 75 VDC Shock (IEC 60068-2-27) 30 g / 11 ms, 6 pos, 6 neg Dielectric test voltage 500 Vac rms (EN60947-1) per axis Rated impulse withstand test 800 V (1.2 / 50 s) (EN60947-1) Free fall (IEC 60068-2-31) 2 times from 1 m, ESPE, PSPE Type 2 100 times from 0.5 m -8 Pig-tail connector (-C2) 3-pol micro MATE-N-LOK PFH 6 x 10 failure per hour d (worst case SRP for CS) Series, AMP/TE Diagnostic coverage 99 % (EN13849-1: 2008) Housing material Body PTE, black Performance level C (EN13849-1: 2008) Front glass PC, black MTTF (worst case full sensor) 298 Years d Connection (worst case full receiver) Cable PVC, Emitter: grey / EN ISO 13849-1, SN 29500 Receiver: black, 368 Years 2 5 m, 3 x 0.14 mm , 2.9 mm (worst case full emitter) Weight EN ISO 13849-1, SN 29500 Emitter 80 g Electrostatic discharge Receiver 80 g (EN61000-4-2) CE-marking EN12445, EN12453, Contact discharge > 12 kV EN12978, EN 60947-5-2 Air discharge > 8 kV UL-Approval cURus UL325 Radiated RF electromagnetic cULus UL508, CSA-C22.2 No.247 fields (EN 61000-4-3) > 10 V/m Electrical fast transients/burst (EN 61000-4-4) 4 kV 2 Specifications are subject to change without notice. Rev. *1* (17.02.2016)