Photoelectrics Diffuse-reflective Type PD30CND10....DU Miniature sensor range Range: 1 m Sensitivity adjustment by Teach-In programming Modulated, red light 660 nm Supply voltage: 10 to 30 VDC Output: 100 mA, NPN or PNP preset Make or break switching function programmable LED indication for output, stability and power ON Protection: reverse polarity, short circuit and transients Cable and plug versions Excellent EMC performance Dust alarm output Product Description Ordering Key PD30CND10PPM5DU The PD30CND10 sensor The Teach-In function for Type family comes in a compact adjustment of the sensitivi- Housing style 10 x 30 x 20 mm reinforced ty makes the sensors highly Housing size PMMA/ABS housing. The flexible. The output type is Housing material sensors are useful in appli- preset (NPN or PNP), and Housing length cations where high accuracy the output switching function Detection principle detection as well as small is one NO or NC output and Sensing distance size is required. Compact one dust output NO or NC. Output type housing and high power Output configuration LED for excellent perfor- Connection type mance-size ratio. Dust Output Type Selection Housing Range Connection Ordering no. Ordering no. W x H x D S NPN PNP n Make and break switching Make and break switching 10 x 30 x 20 mm 1 m Cable PD 30 CND 10 NPDU PD 30 CND 10 PPDU 10 x 30 x 20 mm 1 m Plug PD 30 CND 10 NPM5DU PD 30 CND 10 PPM5DU Specifications EN 60947-5-2 Rated operating distance (S ) Up to 1 m, Protection Short-circuit, reverse polarity n reference target Kodak test and transients card R27, white, 90% Light source GaAlAs, LED, 660 nm reflective, 200 x 200 mm Light type Red, modulated Blind zone 20 mm Sensing angle 2 Sensitivity Adjustable by Teach-In Ambient light 10,000 lux Temperature drift 0.1%/C Light spot 110 mm 1.5 m Hysteresis (H) Operating frequency (f) 1000 Hz (differential travel) 10% Response time Rated operational volt. (U ) 10 to 30 VDC B OFF-ON (t ) 0.5 ms (ripple included) ON ON-OFF (t ) 0.5 ms OFF Ripple (U ) 10% rpp Power ON delay (t ) 300 ms v Output current Output function Continuous (Ie) 100 mA NPN and PNP Preset Short-time (I) 100 mA Output configuration NO or NC (max. load capacity 100 nF) Programming options No load supply current (Io) 30 mA 24 VDC Output pin 4 black NO or NC Minimum operational current (Im) 0.5 mA Output pin 2 white NO or NC (dust) OFF-state current (Ir ) 100 A Dust alarm output Voltage drop (Ud ) 2.4 VDC 100 mA Delay on operate 20 ms Specifications are subject to change without notice (05.07.2016) 1 PD30CND10....DU Specifications (cont.) EN 60947-5-2 Indication Rated insulation voltage 500 VAC (rms) Output ON LED, yellow Housing material Signal stability ON and Body ABS Power ON LED, green Frontglas PMMA Red Environment Connection Installation category III (IEC 60664/60664A Cable PVC, black, 2 m 60947-1) 2 4 x 0.14 mm , = 3.3 mm Pollution degree 3 (IEC 60664/60664A Plug M8, 4-pin (CON. 54-series) 60947-1) Weight Degree of protection IP 67 (IEC 60529 60947-1) Cable version 40 g Ambient temperature Plug version 10 g Operating -25 to +60C (-13 to +140F) CE-marking Yes Storage -40 to +70C (-40 to +158F) Approvals cULus (UL508 + CSA) Vibration 10 to 55 Hz, 0.5 mm/7.5 g (IEC 60068-2-6) Shock 30 g / 11ms, 3 pos, 3 neg per axis (IEC 60068-2-6, 60068-2-32) Operation Diagram Tv = Power ON delay ON Power supply OFF Present Object Not Present Tv ON Break Output (N.C.) OFF Tv ON Make Output (N.O.) OFF Wiring Diagrams NPN PNP 1 BN V 1 BN V 4 BK 2 WH* 2 WH* 4 BK 3 BU 3 BU GND GND *Dust Output *Dust Output Detection Diagram Excess Gain 1,000 40 30 20 100 10 0 -10 10 -20 -30 -40 1 0 200 400 600 800 1000 1200 1400 10 100 1,000 10,000 Distance (mm) Distance (mm) 2 Specifications are subject to change without notice (05.07.2016) (mm) Exess gain